Visibility of trabecular meshwork by standard and polarization-sensitive optical coherence tomography

被引:47
|
作者
Yasuno, Yoshiaki [1 ,2 ]
Yamanari, Masahiro [2 ]
Kawana, Keisuke [2 ,3 ]
Miura, Masahiro [2 ,4 ]
Fukuda, Shinichi [2 ,3 ]
Makita, Shuichi [2 ,5 ]
Sakai, Shingo [6 ]
Oshika, Tetsuro [2 ,3 ]
机构
[1] Univ Tsukuba, Inst Appl Phys, Computat Opt Grp, Tsukuba, Ibaraki 3058573, Japan
[2] Univ Tsukuba, Computat Opt & Ophthalmol Grp, Tsukuba, Ibaraki 3058573, Japan
[3] Univ Tsukuba, Inst Clin Med, Dept Ophthalmol, Tsukuba, Ibaraki 3058573, Japan
[4] Tokyo Med Univ, Dept Ophthalmol, Tokyo 1600023, Japan
[5] Univ Tsukuba, Computat Opt Grp, Tsukuba, Ibaraki 3058573, Japan
[6] Kanebo Cosmet Inc, Basic Res Lab, Kanagawa 2500002, Japan
基金
日本科学技术振兴机构;
关键词
optical coherence tomography; polarization; birefringence; ophthalmology; anterior eye segment; glaucoma; ANTERIOR SEGMENT; HUMAN RETINA; IN-VIVO; GLAUCOMA; POPULATION; PREVALENCE; BIREFRINGENCE; TISSUE; POLARIMETRY; MODULATION;
D O I
10.1117/1.3499421
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Polarization-sensitive optical coherence tomography (PS-OCT) is known to be advantageous because of its additional tissue-specific contrast of the anterior eye. So far, this advantage has been shown only qualitatively. We evaluate the improved visibility afforded by 3-D PS corneal and anterior eye segment OCT (PS-CAS-OCT) in visualizing the trabecular meshwork (TM) based on statistical evidences. A total of 31 normal subjects participated in this study. The anterior eye segments of both the eyes of the subjects are scanned using a custom-made PS-CAS-OCT and the standard-scattering OCT (S-OCT) and polarization-sensitive phase-retardation OCT (P-OCT) images are obtained. Three graders grade the visibility of the TM using a four-leveled grading system. The intergrader agreement, intermodality differences, and interquadrant dependence of visibility are statistically examined. All three of three combinations of graders show substantial agreement in visibility with P-OCT (p = 0.74, 0.70, and 0.68, Spearman's correlation), while only one of three shows substantial agreement with S-OCT (p = 0.72). Significant dependence of the visibility on the modality (S-OCT versus P-OCT) and quadrants are found by the analysis of variance. A subsequent Wilcoxon signed-rank test reveals significantly improved visibility. PS-CAS-OCT may become a useful tool for screening angle-closure glaucoma. (C) 2010 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3499421]
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Optic axis determination by fibre-based polarization-sensitive swept-source optical coherence tomography
    Lu, Zenghai
    Kasaragod, Deepa K.
    Matcher, Stephen J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (04) : 1105 - 1122
  • [42] Birefringence measurements in human skin using polarization-sensitive optical coherence tomography
    Pierce, MC
    Strasswimmer, J
    Park, BH
    Cense, B
    de Boer, JF
    LASERS IN SURGERY: ADVANCED CHARACTERIZATION, THERAPEUTICS, AND SYSTEMS XIV, 2004, 5312 : 35 - 40
  • [43] Needle guidance with Doppler-tracked polarization-sensitive optical coherence tomography
    Harper, Danielle J.
    Kim, Yongjoo
    Gomez-Ramirez, Alejandra
    Vakoc, Benjamin J.
    JOURNAL OF BIOMEDICAL OPTICS, 2023, 28 (10)
  • [44] Correlation of collagen synthesis with polarization-sensitive optical coherence tomography Imaging of in vitro human atherosclerosis
    Kuo, WC
    Shyu, JJ
    Chou, NK
    Lai, CM
    Tien, EK
    Huang, HJ
    Chou, C
    Jan, GJ
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE IX, 2005, 5690 : 563 - 571
  • [45] Evaluation of photodamage with polarization-sensitive optical coherence tomography
    Nguyen Hoang Trung
    Lee, Cheng-Yu
    Tsai, Meng-Tsan
    BIOMEDICAL IMAGING AND SENSING CONFERENCE, 2018, 10711
  • [46] Polarization-Sensitive Spectral Interferometric Optical Coherence Tomography for Human Skin Imaging
    Shuichi Makita
    Yoshiaki Yasuno
    Yasunori Sutoh
    Masahide Itoh
    Toyohiko Yatagai
    Optical Review, 2003, 10 : 366 - 369
  • [47] Birefringence and nerve fiber orientation in healthy in vivo primate RNFL with enhanced polarization-sensitive optical coherence tomography (EPS-OCT)
    Kemp, NJ
    Zaatari, HN
    Park, J
    Milner, TE
    Rylander, HG
    OPHTHALMIC TECHNOLOGIES XV, 2005, 5688 : 100 - 111
  • [48] Laryngeal Imaging with Polarization-sensitive Optical Coherence Tomography
    Burns, James A.
    Kim, Ki Hean
    Anderson, R. Rox
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS VII, 2011, 7883
  • [49] Measurement of Multiple Optical Parameters of Birefrigent Sample Using Polarization-Sensitive Optical Coherence Tomography
    Liao, Chia-Chi
    Lo, Yu-Lung
    Yeh, Cheng-Yen
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2009, 27 (5-8) : 483 - 493
  • [50] Performance of Automated Drusen Detection by Polarization-Sensitive Optical Coherence Tomography
    Schlanitz, Ferdinand G.
    Baumann, Bernhard
    Spalek, Tobias
    Schuetze, Christopher
    Ahlers, Christian
    Pircher, Michael
    Goetzinger, Erich
    Hitzenberger, Christoph K.
    Schmidt-Erfurth, Ursula
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (07) : 4571 - 4579