Visibility of trabecular meshwork by standard and polarization-sensitive optical coherence tomography

被引:47
|
作者
Yasuno, Yoshiaki [1 ,2 ]
Yamanari, Masahiro [2 ]
Kawana, Keisuke [2 ,3 ]
Miura, Masahiro [2 ,4 ]
Fukuda, Shinichi [2 ,3 ]
Makita, Shuichi [2 ,5 ]
Sakai, Shingo [6 ]
Oshika, Tetsuro [2 ,3 ]
机构
[1] Univ Tsukuba, Inst Appl Phys, Computat Opt Grp, Tsukuba, Ibaraki 3058573, Japan
[2] Univ Tsukuba, Computat Opt & Ophthalmol Grp, Tsukuba, Ibaraki 3058573, Japan
[3] Univ Tsukuba, Inst Clin Med, Dept Ophthalmol, Tsukuba, Ibaraki 3058573, Japan
[4] Tokyo Med Univ, Dept Ophthalmol, Tokyo 1600023, Japan
[5] Univ Tsukuba, Computat Opt Grp, Tsukuba, Ibaraki 3058573, Japan
[6] Kanebo Cosmet Inc, Basic Res Lab, Kanagawa 2500002, Japan
基金
日本科学技术振兴机构;
关键词
optical coherence tomography; polarization; birefringence; ophthalmology; anterior eye segment; glaucoma; ANTERIOR SEGMENT; HUMAN RETINA; IN-VIVO; GLAUCOMA; POPULATION; PREVALENCE; BIREFRINGENCE; TISSUE; POLARIMETRY; MODULATION;
D O I
10.1117/1.3499421
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Polarization-sensitive optical coherence tomography (PS-OCT) is known to be advantageous because of its additional tissue-specific contrast of the anterior eye. So far, this advantage has been shown only qualitatively. We evaluate the improved visibility afforded by 3-D PS corneal and anterior eye segment OCT (PS-CAS-OCT) in visualizing the trabecular meshwork (TM) based on statistical evidences. A total of 31 normal subjects participated in this study. The anterior eye segments of both the eyes of the subjects are scanned using a custom-made PS-CAS-OCT and the standard-scattering OCT (S-OCT) and polarization-sensitive phase-retardation OCT (P-OCT) images are obtained. Three graders grade the visibility of the TM using a four-leveled grading system. The intergrader agreement, intermodality differences, and interquadrant dependence of visibility are statistically examined. All three of three combinations of graders show substantial agreement in visibility with P-OCT (p = 0.74, 0.70, and 0.68, Spearman's correlation), while only one of three shows substantial agreement with S-OCT (p = 0.72). Significant dependence of the visibility on the modality (S-OCT versus P-OCT) and quadrants are found by the analysis of variance. A subsequent Wilcoxon signed-rank test reveals significantly improved visibility. PS-CAS-OCT may become a useful tool for screening angle-closure glaucoma. (C) 2010 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3499421]
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Skin characterization of diabetes mellitus revealed by polarization-sensitive optical coherence tomography imaging
    Feng, Wei
    Wang, Lisi
    Liu, Chun-Jie
    Zhang, Chao
    JOURNAL OF BIOMEDICAL OPTICS, 2024, 29 (03)
  • [32] Vector-based analysis for polarization-sensitive optical coherence tomography
    Park, BH
    Pierce, MC
    Cense, B
    de Boer, JF
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE VIII, 2004, 5316 : 397 - 403
  • [33] Birefringent tissue-mimicking phantom for polarization-sensitive optical coherence tomography imaging
    Chang, Shuang
    Handwerker, Jessica
    Giannico, Giovanna A.
    Chang, Sam S.
    Bowden, Audrey K.
    JOURNAL OF BIOMEDICAL OPTICS, 2022, 27 (07)
  • [34] Optic axis mapping with catheter-based polarization-sensitive optical coherence tomography
    Villiger, Martin
    Braaf, Boy
    Lippok, Norman
    Otsuka, Kenichiro
    Nadkarni, Seemantini K.
    Bouma, Brett E.
    OPTICA, 2018, 5 (10): : 1329 - 1337
  • [35] Determination of burn depth by polarization-sensitive optical coherence tomography
    Srinivas, SM
    de Boer, JF
    Park, H
    Keikhanzadeh, K
    Huang, HEL
    Zhang, J
    Jung, WQ
    Chen, ZP
    Nelson, JS
    JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (01) : 207 - 212
  • [36] Fiber-based polarization-sensitive optical coherence tomography
    Saxer, CE
    de Boer, JF
    Park, BH
    Zhao, YH
    Chen, YP
    Nelson, JS
    COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS IV, 2000, 3915 : 68 - 75
  • [37] Polarization-Sensitive Optical Coherence Tomography for Brain Tumor Characterization
    Li, Yun-Qian
    Chiu, Kai-Shih
    Liu, Xin-Rui
    Hsiao, Tien-Yu
    Zhao, Gang
    Li, Shan-Ji
    Lin, Ching-Po
    Sun, Chia-Wei
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2019, 25 (01)
  • [38] Automatic spectral calibration for polarization-sensitive optical coherence tomography
    Chen, Yan
    Li, Zhongliang
    Nan, Nan
    Bu, Yang
    Wang, Xuan
    Pan, Liuhua
    Wang, Xiangzhao
    OPTICS EXPRESS, 2017, 25 (20): : 23605 - 23618
  • [39] Polarization sensitive optical coherence tomography of the rabbit eye
    Ducros, MG
    de Boer, JF
    Huang, HE
    Chao, LC
    Chen, ZP
    Nelson, JS
    Milner, TE
    Rylander, HG
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1999, 5 (04) : 1159 - 1167
  • [40] Polarization-sensitive spectral interferometric optical coherence tomography for human skin imaging
    Makita, S
    Yasuno, Y
    Sutoh, Y
    Itoh, M
    Yatagai, T
    OPTICAL REVIEW, 2003, 10 (05) : 366 - 369