Visibility of trabecular meshwork by standard and polarization-sensitive optical coherence tomography

被引:47
|
作者
Yasuno, Yoshiaki [1 ,2 ]
Yamanari, Masahiro [2 ]
Kawana, Keisuke [2 ,3 ]
Miura, Masahiro [2 ,4 ]
Fukuda, Shinichi [2 ,3 ]
Makita, Shuichi [2 ,5 ]
Sakai, Shingo [6 ]
Oshika, Tetsuro [2 ,3 ]
机构
[1] Univ Tsukuba, Inst Appl Phys, Computat Opt Grp, Tsukuba, Ibaraki 3058573, Japan
[2] Univ Tsukuba, Computat Opt & Ophthalmol Grp, Tsukuba, Ibaraki 3058573, Japan
[3] Univ Tsukuba, Inst Clin Med, Dept Ophthalmol, Tsukuba, Ibaraki 3058573, Japan
[4] Tokyo Med Univ, Dept Ophthalmol, Tokyo 1600023, Japan
[5] Univ Tsukuba, Computat Opt Grp, Tsukuba, Ibaraki 3058573, Japan
[6] Kanebo Cosmet Inc, Basic Res Lab, Kanagawa 2500002, Japan
基金
日本科学技术振兴机构;
关键词
optical coherence tomography; polarization; birefringence; ophthalmology; anterior eye segment; glaucoma; ANTERIOR SEGMENT; HUMAN RETINA; IN-VIVO; GLAUCOMA; POPULATION; PREVALENCE; BIREFRINGENCE; TISSUE; POLARIMETRY; MODULATION;
D O I
10.1117/1.3499421
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Polarization-sensitive optical coherence tomography (PS-OCT) is known to be advantageous because of its additional tissue-specific contrast of the anterior eye. So far, this advantage has been shown only qualitatively. We evaluate the improved visibility afforded by 3-D PS corneal and anterior eye segment OCT (PS-CAS-OCT) in visualizing the trabecular meshwork (TM) based on statistical evidences. A total of 31 normal subjects participated in this study. The anterior eye segments of both the eyes of the subjects are scanned using a custom-made PS-CAS-OCT and the standard-scattering OCT (S-OCT) and polarization-sensitive phase-retardation OCT (P-OCT) images are obtained. Three graders grade the visibility of the TM using a four-leveled grading system. The intergrader agreement, intermodality differences, and interquadrant dependence of visibility are statistically examined. All three of three combinations of graders show substantial agreement in visibility with P-OCT (p = 0.74, 0.70, and 0.68, Spearman's correlation), while only one of three shows substantial agreement with S-OCT (p = 0.72). Significant dependence of the visibility on the modality (S-OCT versus P-OCT) and quadrants are found by the analysis of variance. A subsequent Wilcoxon signed-rank test reveals significantly improved visibility. PS-CAS-OCT may become a useful tool for screening angle-closure glaucoma. (C) 2010 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3499421]
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Optical polarization tractography based on polarization-sensitive optical coherence tomography
    Yao, Gang
    Wang, Yuanbo
    Ravanfar, Mohammadreza
    Azinfar, Leila
    Yao, Xuan
    Zhang, Keqing
    Duan, Dongsheng
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XX, 2016, 9697
  • [2] Peripapillary Rat Sclera Investigated In Vivo With Polarization-Sensitive Optical Coherence Tomography
    Baumann, Bernhard
    Rauscher, Sabine
    Gloesmann, Martin Gl
    Goetzinger, Erich G.
    Pircher, Michael
    Fialova, Stanislava
    Groeger, Marion
    Hitzenberger, Christoph K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (11) : 7686 - 7696
  • [3] Analysis of optimum conditions of depolarization imaging by polarization-sensitive optical coherence tomography in the human retina
    Sugita, Mitsuro
    Pircher, Michael
    Zotter, Stefan
    Baumann, Bernhard
    Saito, Kenichi
    Makihira, Tomoyuki
    Tomatsu, Nobuhiro
    Sato, Makoto
    Hitzenberger, Christoph K.
    JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (01)
  • [4] Noise model for polarization-sensitive optical coherence tomography
    Williams, Paul A.
    Kemp, Nate J.
    Ives, David
    Park, Jesung
    Dwelle, Jordan C.
    Rylander, H. Grady, II
    Milner, Thomas E.
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079
  • [5] Polarization-sensitive optical coherence tomography imaging of the anterior mouse eye
    Baumann, Bernhard
    Augustin, Marco
    Lichtenegger, Antonia
    Harper, Danielle J.
    Muck, Martina
    Eugui, Pablo
    Wartak, Andreas
    Pircher, Michael
    Hitzenberger, Christoph K.
    JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (08)
  • [6] Polarization-sensitive optical coherence tomography with a single input polarization state
    Villiger, Martin
    Xiong, Qiaozhou
    Wang, Nanshuo
    Liu, Xinyu
    Liu, Linbo
    Bouma, Brett E.
    2019 IEEE PHOTONICS CONFERENCE (IPC), 2019,
  • [7] Polarization-sensitive swept-source optical coherence tomography with continuous polarization modulation
    Yamanari, Masahiro
    Makita, Shuichi
    Yatagai, Toyohiko
    Yasuno, Yoshiaki
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE XII, 2008, 6847
  • [8] Conical scan polarization-sensitive optical coherence tomography
    Lu, Zenghai
    Kasaragod, Deepa
    Matcher, Stephen J.
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (03): : 752 - 762
  • [9] Polarization-sensitive interleaved optical coherence tomography
    Duan, Lian
    Marvdashti, Tahereh
    Ellerbee, Audrey K.
    OPTICS EXPRESS, 2015, 23 (10): : 13693 - 13703
  • [10] Endoscopic polarization-sensitive optical coherence tomography
    Pierce, Mark C.
    Shishkov, Milen
    Park, B. Hyle
    Nassif, Nader
    Bouma, Brett E.
    Tearney, Guillermo J.
    de Boer, Johannes F.
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079