Fracture resistance of all-ceramic and metal-ceramic inlays

被引:0
作者
Esquivel-Upshaw, JF
Anusavice, KJ
Reid, M
Yang, MCK
Lee, RB
机构
[1] Univ Florida, Coll Dent, Dept Prosthodont, Gainesville, FL 32610 USA
[2] Univ Florida, Coll Dent, Dept Dent Biomat, Gainesville, FL 32610 USA
[3] Univ Florida, Coll Dent, Dept Stat, Gainesville, FL 32610 USA
[4] Univ Florida, Coll Dent, Div Biostat, Gainesville, FL 32610 USA
[5] Univ Florida, Coll Dent, Dept Biostat, Gainesville, FL 32610 USA
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Metal-ceramic inlay designs were developed to determine if the esthetic qualities of all-ceramic inlays could be duplicated and at the same time improve their strength and stability. The objectives of this study were to: (1) compare the fracture resistance of metal-ceramic inlays with that of all-ceramic inlays; (2) determine the correlation between the degree of preparation taper and fracture resistance; and (3) determine the correlation between marginal gap width and fracture resistance. Materials and Methods: Inlay preparations were made on 60 Dentoform teeth, with 30 teeth allocated for metal-ceramic inlays and 30 teeth for all-ceramic inlays. Each group was further subdivided into 5-, 10-, and 20-degree taper preparations. Metal-ceramic inlays were fabricated using Goldtech Bio 2000 metal and Ceramco porcelain extending to the margin, while all-ceramic inlays were made from Empress II ceramic. Marginal gap widths were measured at six critical areas after fabrication. The load at failure was measured using an Instron Universal Testing Machine. Results: The mean fracture load for all-ceramic inlays and metal-ceramic inlays at 5, 10, and 20 degrees was 70 +/- 40 N, 48 +/- 37 N, 33 +/- 7 N, and 40 +/- 23 N, 29 +/- 22 N, and 14 +/- 4 N, respectively. The mean gap width was 105 mum and 126 mum for all-ceramic and metal-ceramic inlays, respectively. Conclusion: The mean fracture load for Empress inlays was significantly higher than that for metal-ceramic inlays. Inlays with a 5-degree taper were significantly more fracture resistant than those with a 20-degree taper. There was no relation between marginal gap width and fracture resistance.
引用
收藏
页码:109 / 114
页数:6
相关论文
共 30 条
[1]  
ANUSAVICE KJ, 1996, PHILLIPS SCI DENT MA, P594
[2]   The clinical performance of ceramic inlays: A review [J].
Bergman, MA .
AUSTRALIAN DENTAL JOURNAL, 1999, 44 (03) :157-168
[3]  
BURKE FJT, 1993, OPER DENT, V18, P230
[4]  
CHARBENEAU GT, 1988, PRINCIPLES PRACTICE, P352
[5]   MECHANICAL-PROPERTIES OF METAL-CERAMIC ALLOYS AT HIGH-TEMPERATURE [J].
CHEW, CL ;
NORMAN, RD ;
STEWART, GP .
DENTAL MATERIALS, 1990, 6 (04) :223-227
[6]   EFFECTS OF DESIGN ON STRESS DISTRIBUTION OF INTRACORONAL GOLD RESTORATIONS [J].
FARAH, JW ;
DENNISON, JB ;
POWERS, JM .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1977, 94 (06) :1151-1154
[7]  
Fransson B, 1985, Dent Mater, V1, P197, DOI 10.1016/S0109-5641(85)80019-1
[9]   A CLINICAL-EVALUATION OF PORCELAIN INLAYS [J].
ISIDOR, F ;
BRONDUM, K .
JOURNAL OF PROSTHETIC DENTISTRY, 1995, 74 (02) :140-144
[10]   THE FIT OF PROCERA TITANIUM CROWNS - AN INVITRO AND CLINICAL-STUDY [J].
KARLSSON, S .
ACTA ODONTOLOGICA SCANDINAVICA, 1993, 51 (03) :129-134