Disinfection of polymicrobial urines by electrochemical oxidation: Removal of antibiotic-resistant bacteria and genes

被引:25
|
作者
Herraiz-Carbone, Miguel [1 ]
Cotillas, Salvador [2 ]
Lacasa, Engracia [1 ]
Vasileva, Marina [1 ]
Sainz de Baranda, Caridad [3 ]
Riquelme, Eva [3 ]
Canizares, Pablo [4 ]
Saez, Cristina [4 ]
机构
[1] Univ Castilla La Mancha, Higher Tech Sch Ind Engn, Dept Chem Engn, Edificio Infante Don Juan Manuel,Campus Univ S-N, Albacete 02071, Spain
[2] Univ Complutense Madrid, Fac Chem Sci, Dept Chem Engn & Mat, Ave Complutense S-N, Madrid 28040, Spain
[3] Univ Hosp Complex Albacete, Clin Parasitol & Microbiol Area, C Hermanos Falco 37, Albacete 02006, Spain
[4] Univ Castilla La Mancha, Fac Chem Sci & Technol, Dept Chem Engn, Edificio Enrique Costa Novella,Campus Univ S-N, Ciudad Real 13005, Spain
关键词
Antibiotic-resistant bacteria; Antibiotic resistance genes; Hospital; Urine; Electrochemical disinfection; HOSPITAL WASTE-WATER; GRAM-POSITIVE BACTERIA; ESCHERICHIA-COLI; DRINKING-WATER; CELLULAR IMPERMEABILITY; E; COLI; INACTIVATION; ENTEROBACTERIACEAE; PNEUMONIAE; MECHANISMS;
D O I
10.1016/j.jhazmat.2021.128028
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this work, data obtained from the University Hospital Complex of Albacete (Spain) were selected as a case study to carry out the disinfection experiments. To do this, different configurations of electrochemical reactors were tested for the disinfection of complex urines. Results showed that 4-6 logs bacterial removal were achieved for every bacterium tested when working with a microfluidic flow-through reactor after 180 min (0.423 Ah dm-3). The MIKROZON (R) cell reached a total disinfection after 60 min (1.212 Ah dm-3), causing severe damages induced in the cell walls observed in SEM images. The concentration profiles of the electrogenerated disinfectants in solution could explain the differences observed. Additionally, a mean decrease in the ARGs concentration ranked as follows: blaKPC (4.18-logs) > blaTEM (3.96-logs) > ermB (3.23-logs) using the MIKROZON (R) cell. This electro-ozonizer could be considered as a suitable alternative to reduce the risk of antibiotic resistance spread. Hence, this study provides an insight into different electrochemical reactors for the disinfection of complex hospital urine matrices and contributes to reduce the spread of antibiotic resistance through the elimination of ARGs. A topic of great importance nowadays that needs to be further studied.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Overcoming Antibiotic-Resistant Bacteria
    Ariyanchira, Syamala
    GENETIC ENGINEERING & BIOTECHNOLOGY NEWS, 2010, 30 (15): : 18 - 18
  • [32] CONTROL OF ANTIBIOTIC-RESISTANT BACTERIA
    不详
    BULLETIN OF THE WORLD HEALTH ORGANIZATION, 1983, 61 (03): : 423 - 433
  • [33] EMERGENCE OF ANTIBIOTIC-RESISTANT BACTERIA
    FINLAND, M
    NEW ENGLAND JOURNAL OF MEDICINE, 1955, 253 (22): : 969 - 979
  • [34] Report on antibiotic-resistant bacteria
    Pugliese, G
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 1996, 17 (03): : 187 - 187
  • [35] SPREAD OF ANTIBIOTIC-RESISTANT BACTERIA
    MARSH, F
    LANCET, 1956, 271 (OCT6): : 729 - 729
  • [36] The Impacts of Chlorine and Disinfection Byproducts on Antibiotic-Resistant Bacteria (ARB) and Their Conjugative Transfer
    Kong, Cen
    He, Xin
    Guo, Meiting
    Ma, Shunjun
    Xu, Bin
    Tang, Yulin
    WATER, 2022, 14 (19)
  • [37] SPREAD OF ANTIBIOTIC-RESISTANT BACTERIA
    不详
    LANCET, 1956, 271 (AUG11): : 293 - 293
  • [38] EMERGENCE OF ANTIBIOTIC-RESISTANT BACTERIA
    FINLAND, M
    NEW ENGLAND JOURNAL OF MEDICINE, 1955, 253 (21): : 909 - 922
  • [39] EMERGENCE OF ANTIBIOTIC-RESISTANT BACTERIA
    FINLAND, M
    NEW ENGLAND JOURNAL OF MEDICINE, 1955, 253 (23): : 1019 - 1028
  • [40] Antibiotic-resistant bacteria on the rise
    Gewanter, B
    Klein, R
    Jones, S
    AMERICAN JOURNAL OF NURSING, 2002, 102 (03) : 116 - 116