摘要
Purpose: To develop a new automated filtering technique and to evaluate its ability to compensate for the known low contrast-to-noise ratio (CNR) in dynamic contrast material-enhanced (DCE) magnetic resonance (MR) and computed tomographic (CT) data, without substantial loss of information. Materials and Methods: Clinical data acquisition for this study was approved by the institutional review board. Principal component analysis (PCA) was combined with the fraction of residual information (FRI) criterion to optimize the balance between noise reduction efficiency and information conservation. The PCA FRI filter was evaluated in 15 DCE MR imaging data sets and 15 DCE CT data sets by two radiologists who performed visual analysis and quantitative assessment of noise reduction after filtering. Results: Visual evaluation revealed a substantial noise reduction while conserving information in 90% of MR imaging cases and 87% of CT cases for image analysis and in 93% of MR imaging cases and 90% of CT cases for signal analysis. Efficient denoising enabled improvement in structure characterization in 60% of MR imaging cases and 77% of CT cases. After filtering, CNR was improved by 2.06 +/- 0.89 for MR imaging (P < .01) and by 5.72 +/- 4.82 for CT (P < .01). Conclusion: This PCA FRI filter demonstrates noise reduction efficiency and information conservation for both DCE MR data and DCE CT data. FRI analysis enabled automated optimization of the parameters for the PCA filter and provided an optional visual control of residual information losses. The robust and fast PCA FRI filter may improve qualitative or quantitative analysis of DCE imaging in a clinical context. (C)RSNA, 2010 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.10100231/-/DC1
引用
收藏
页码:435 / 445
页数:11
相关论文
共 50 条
  • [1] Signal-to-noise ratio, contrast-to-noise ratio and pharmacokinetic modeling considerations in dynamic contrast-enhanced magnetic resonance imaging
    Li, Xin
    Huang, Wei
    Rooney, William D.
    MAGNETIC RESONANCE IMAGING, 2012, 30 (09) : 1313 - 1322
  • [2] Quality assurance in MRI breast screening: comparing signal-to-noise ratio in dynamic contrast-enhanced imaging protocols
    Kousi, Evanthia
    Borri, Marco
    Dean, Jamie
    Panek, Rafal
    Scurr, Erica
    Leach, Martin O.
    Schmidt, Maria A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (01) : 37 - 49
  • [3] Dynamic Contrast-Enhanced Breast MR Imaging
    Moon, Marianne
    Cornfeld, Daniel
    Weinreb, Jeffrey
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2009, 17 (02) : 351 - +
  • [4] Dynamic Contrast-Enhanced MR Imaging in Head and Neck Cancer
    Kabadi, Suraj J.
    Fatterpekar, Girish M.
    Anzai, Yoshimi
    Mogen, Jonathan
    Hagiwara, Mari
    Patel, Sohil H.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2018, 26 (01) : 135 - +
  • [5] Dynamic contrast-enhanced MRI diagnostics in oncology via principal component analysis
    Bruwer, Mark-John
    MacGregor, John F.
    Noseworthy, Michael D.
    JOURNAL OF CHEMOMETRICS, 2008, 22 (11-12) : 708 - 716
  • [6] Quantitative analysis of neovascular permeability in glioma by dynamic contrast-enhanced MR imaging
    Jia, Zhongzheng
    Geng, Daoying
    Xie, Tianwen
    Zhang, Jiaoyan
    Liu, Ying
    JOURNAL OF CLINICAL NEUROSCIENCE, 2012, 19 (06) : 820 - 823
  • [7] Dynamic contrast-enhanced imaging techniques: CT and MRI
    O'Connor, J. P. B.
    Tofts, P. S.
    Miles, K. A.
    Parkes, L. M.
    Thompson, G.
    Jackson, A.
    BRITISH JOURNAL OF RADIOLOGY, 2011, 84 : S112 - S120
  • [8] Quantitative dynamic contrast-enhanced MR imaging analysis of complex adnexal masses: a preliminary study
    Thomassin-Naggara, Isabelle
    Balvay, Daniel
    Aubert, Emilie
    Darai, Emile
    Rouzier, Roman
    Cuenod, Charles A.
    Bazot, Marc
    EUROPEAN RADIOLOGY, 2012, 22 (04) : 738 - 745
  • [9] Celiac Disease: Evaluation with Dynamic Contrast-enhanced MR Imaging
    Masselli, Gabriele
    Picarelli, Antonio
    Di Tola, Marco
    Libanori, Valerio
    Donato, Giuseppe
    Polettini, Elisabetta
    Piermattei, Alessandra
    Palumbo, Piergaspare
    Pittalis, Angelo
    Saponara, Annarita
    Gualdi, Gianfranco
    RADIOLOGY, 2010, 256 (03) : 783 - 790
  • [10] Dynamic Contrast-enhanced MR Imaging in Renal Cell Carcinoma: Reproducibility of Histogram Analysis on Pharmacokinetic Parameters
    Wang, Hai-yi
    Su, Zi-hua
    Xu, Xiao
    Sun, Zhi-peng
    Duan, Fei-xue
    Song, Yuan-yuan
    Li, Lu
    Wang, Ying-wei
    Ma, Xin
    Guo, Ai-tao
    Ma, Lin
    Ye, Hui-yi
    SCIENTIFIC REPORTS, 2016, 6