Tc-99m tetrofosmin scintigraphy as an adjunct to plain-film mammography in palpable breast lesions

被引:18
作者
Fenlon, HM
Phelan, N
Tierney, S
Gorey, T
Ennis, JT
机构
[1] Univ Coll Dublin, Inst Radiol Sci, Dublin 7, Ireland
[2] Mater Misericordiae Hosp, Dept Radiol, Dublin, Ireland
[3] Mater Misericordiae Hosp, Dept Surg, Dublin, Ireland
关键词
D O I
10.1016/S0009-9260(98)80028-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: To investigate the use of Tc-99m tetrofosmin as a breast imaging agent and to compare results of Tc-99m tetrofosmin scintimammography with plain-film mammography and pathological outcome. Patients and Methods: Forty-four patients (mean age, 51 years; range 26-79 years) with a palpable breast mass requiring fine needle aspiration biopsy (FNAB) were prospectively studied, All patients had Tc-99m tetrofosmin scintimammography. Patients over 35 years of age had two view mammography performed on the same day, FNAB was performed within 2 weeks of imaging, and patients referred for surgery as appropriate. Results of scintigraphy and plain-him mammography were correlated with pathological outcome. Results: Of the 44 patients, 21 had biopsy proven malignancy while 23 had benign lesions. Of the 21 patients with carcinoma, 20 (95.2 %) had positive Tc-99m tetrofosmin scintimammography while 21 (91.3 %) of the 23 patients with benign histology had negative scintigraphy, The sensitivity of scintimammography was 95.24%, the specificity was 91.3%, with a positive predictive value of 90.9% and a negative predictive value of 95.45%, Thirty-eight patients had two view mammography performed (six patients were <35 years of age), Of these 38 patients, 21 had biopsy proven malignancy white 17 had benign histology tall patients <35 years of age had benign histology). Of the 21 patients with malignancy, plain-film mammography was suspicious for malignancy in 17 (81%) while four were reported as benign, Of the 17 with benign disease, 14 patients (82.4%) had benign appearances on plain-film mammography while three (18%) had one or more findings suspicious for malignancy. The sensitivity of plain-film mammography in our group was 81%, with a specificity of 82.4%, a positive predictive value of 85% and a negative predictive value of 77.8%, Tc-99m tetrofosmin scintimammography correctly characterized all seven lesions where mammographic evaluation was limited because df dense breast parenchyma or previous surgery and/or radiotherapy. Conclusion: Tc-99m tetrofosmin scintimammography is an accurate. well tolerated and non-invasive method of differentiating benign from malignant palpable breast lesions. Negative Tc-99m tetrofosmin scintimammography excludes malignancy with a high degree of confidence while false-positive scintigraphy can occur in cases of proliferative dysplasia and hypercellular fibroadenoma. Tc-99m tetrofosmin scintimammography is particularly useful when plain-film mammography is indeterminate or limited in patients with dense breasts or a history of previous surgery and/or radiotherapy.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 33 条
[1]   Evaluation of malignant and benign lung lesions with Tc-99(m)-tetrofosmin [J].
Atasever, T ;
Gokcora, N ;
Vural, G ;
Cetin, N ;
Ozturk, C ;
Unlu, M .
NUCLEAR MEDICINE COMMUNICATIONS, 1996, 17 (07) :577-582
[2]   CONCORDANT UPTAKE OF TC-99M SESTAMIBI AND TL-201 IN UNSUSPECTED BREAST-TUMOR [J].
CAMPEAU, RJ ;
KRONEMER, KA ;
SUTHERLAND, CM .
CLINICAL NUCLEAR MEDICINE, 1992, 17 (12) :936-937
[3]  
*COMM EUR COMM, 1996, EUR GUID QUAL ASS MA
[4]  
DELMONMOINGEON LI, 1990, CANCER RES, V50, P2198
[5]  
GREENSTEIN OS, 1994, RADIOLOGY, V190, P485
[6]  
HABBEMA JDF, 1986, JNCI-J NATL CANCER I, V77, P317
[7]   MR IMAGING OF THE BREAST [J].
HARMS, SE ;
FLAMIG, DP .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (01) :277-283
[8]   EARLY BREAST-CANCER - DETECTION OF RECURRENCE AFTER CONSERVATIVE SURGERY AND RADIATION-THERAPY [J].
HASSELL, PR ;
OLIVOTTO, IA ;
MUELLER, HA ;
KINGSTON, GW ;
BASCO, VE .
RADIOLOGY, 1990, 176 (03) :731-735
[9]   MR IMAGING OF THE BREAST - COMPARISON WITH MAMMOGRAPHY AND ULTRASOUND [J].
HEYWANG, SH ;
FENZL, G ;
HAHN, D ;
KRISCHKE, I ;
EDMAIER, M ;
EIERMANN, W ;
BASSERMANN, R .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (04) :615-620
[10]  
HEYWANGKOBRUNNE.SH, 1990, CONTRAST ENHANCED MR