Modeling and simulation of open electrical impedance tomography

被引:5
|
作者
Zhang, Xiao-Ju [1 ]
Chen, Min-You [1 ]
He, Wei [1 ]
He, Chuan-Hong [1 ]
机构
[1] Chongqing Univ, Coll Elect Engn, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing 400044, Peoples R China
关键词
Open electrical impedance tomography; modeling; regularization;
D O I
10.3233/JAE-2010-1177
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to reduce the error in image reconstruction caused by changeable positions of the electrodes in Closed Electrical Impedance Tomography (CEIT), an Open EIT (OEIT) model was proposed using fixed electrode array. The problem is assumed to be a virtual field by defining certain local sensitive area instead of solving the boundary problem in the whole electromagnetic field strictly. Modeling and simulation of OEIT have been conducted to determine reasonable boundary parameters and electrode array structure. The image was reconstructed by iterative Newton-Raphson algorithm with Tikhonov and Variation regularization. The experiment results showed that OEIT achieved good resolution and positioning accuracy, and can be applied to distinguish small difference in conductivity of the biological tissues.
引用
收藏
页码:713 / 720
页数:8
相关论文
共 50 条
  • [21] Finite element modeling for volume phantom in Electrical Impedance Tomography
    Rybina, I. O.
    VISNYK NTUU KPI SERIIA-RADIOTEKHNIKA RADIOAPARATOBUDUVANNIA, 2011, (46): : 72 - 84
  • [22] Electrical impedance tomography
    Lobo, Beatriz
    Hermosa, Cecilia
    Abella, Ana
    Gordo, Federico
    ANNALS OF TRANSLATIONAL MEDICINE, 2018, 6 (02)
  • [23] Electrical impedance tomography
    Saulnier, GJ
    Blue, RS
    Newell, JC
    Isaacson, D
    Edic, PM
    IEEE SIGNAL PROCESSING MAGAZINE, 2001, 18 (06) : 31 - 43
  • [24] Electrical impedance tomography
    Cheney, M
    Isaacson, D
    Newell, JC
    SIAM REVIEW, 1999, 41 (01) : 85 - 101
  • [25] Electrical impedance tomography
    Kotre, CJ
    BRITISH JOURNAL OF RADIOLOGY, 1997, 70 : S200 - S205
  • [26] Electrical Impedance Tomography
    Hinz, Jose
    CURRENT RESPIRATORY MEDICINE REVIEWS, 2009, 5 (02) : 105 - 109
  • [27] Electrical impedance tomography
    Borcea, L
    INVERSE PROBLEMS, 2002, 18 (06) : R99 - R136
  • [28] Electrical impedance tomography
    Costa, Eduardo L. V.
    Lima, Raul Gonzalez
    Amato, Marcelo B. P.
    CURRENT OPINION IN CRITICAL CARE, 2009, 15 (01) : 18 - 24
  • [29] Damage detection of CFRP composites using open electrical impedance tomography
    Fan, Wenru
    Wang, Huaxiang
    Cui, Ziqiang
    2015 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2015, : 1377 - 1381
  • [30] An open-source and easily replicable hardware for Electrical Impedance Tomography
    Brazey, B.
    Haddab, Y.
    Zemiti, N.
    Mailly, F.
    Nouet, P.
    HARDWAREX, 2022, 11