Radiation dosimetry in medicine using II-VI semiconductors

被引:5
作者
Damulira, Edrine
机构
关键词
II -VI Semiconductor; Detector sensitivity; Dosimetry; Radiation detectors; ACCELERATED HEAVY-IONS; GAMMA-CAMERA; QUANTUM-DOTS; X-RAY; SOLAR-CELLS; THIN-FILMS; CDTE; DETECTORS; INACTIVATION; MUTATION;
D O I
10.1016/j.jrras.2022.06.001
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
For several decades, radiation detection has been implemented using mainly silicon (Si) and germanium (Ge). However, group II-VI compound semiconductors such as cadmium telluride (CdTe), cadmium sulfide (CdS), cadmium selenide (CdSe), zinc selenide (ZnSe), zinc oxide (ZnO), zinc sulfide (ZnS), and zinc telluride (ZnTe) have been recently investigated extensively as alternative radiation detectors. Different studies have explored these semiconductors for radiation detection in diagnostic radiology, radiation oncology, nuclear medicine, and non-medical fields such as astronomy. This article aims at demonstrating that II-VI semiconductors are potential and alternative medical radiation detectors, based on the current studies. II-VI semiconductor dosimetry mechanisms and compliance to desirable dosimetry characteristics (e.g., linearity of detector signals to the ra-diation doses, precision, radiation hardness, and sensitivity not depending on beam energy, dose, dose rate, and irradiation angle) are presented and discussed. Additionally, the performances of II-VI-based detectors applied for dosimetry in mainly diagnostic radiology, radiation oncology, and nuclear medicine are evaluated. Even-tually, the dose, dose rate, and energy ranges applicable to the II-VI-based detectors herein are recapitulated. II -VI semiconductors are promising radiation detectors because they comply to the preferred dosimetric metrics as per the current literature. Nevertheless, there is still need for more research to further (a) characterize II-VI semiconductors for medical radiation dosimetry, and (b) compare II-VI semiconductor detectors to conven-tional detectors. Additionally, more II-VI semiconductor detectors should be commercialized to increase the availability of these detectors on the medical dosimetry market.
引用
收藏
页码:72 / 82
页数:11
相关论文
共 129 条
  • [21] Monocrystalline ZnSe as an ionising radiation detector operated over a wide temperature range
    Brodyn, M. S.
    Degoda, V. Ya
    Sofiienko, A. O.
    Kozhushko, B. V.
    Vesna, V. T.
    [J]. RADIATION MEASUREMENTS, 2014, 65 : 36 - 44
  • [22] Radiation effects on II-VI compound-based detectors
    Cavallini, A
    Fraboni, B
    Dusi, W
    Auricchio, N
    Chirco, P
    Zanarini, M
    Siffert, P
    Fougeres, P
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (03) : 770 - 778
  • [23] Optical and structural constants of CdS thin films grown by electron beam vacuum evaporation for solar cells
    Chander, Subhash
    Dhaka, M. S.
    [J]. THIN SOLID FILMS, 2017, 638 : 179 - 188
  • [24] Cherry S. R., 2012, PHYS NUCL MED, V4th
  • [25] Thin-film solar cells: An overview
    Chopra, KL
    Paulson, PD
    Dutta, V
    [J]. PROGRESS IN PHOTOVOLTAICS, 2004, 12 (2-3): : 69 - 92
  • [26] Colak S, 1993, II-VI semiconductor compounds, DOI [10.1142/9789814439770_0016, DOI 10.1142/9789814439770_0016]
  • [27] MUTATION AND INACTIVATION OF CULTURED MAMMALIAN-CELLS EXPOSED TO BEAMS OF ACCELERATED HEAVY-IONS .3. HUMAN-DIPLOID FIBROBLASTS
    COX, R
    MASSON, WK
    [J]. INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1979, 36 (02) : 149 - 160
  • [28] Tandem Solar Cells from Solution-Processed CdTe and PbS Quantum Dots Using a ZnTe-ZnO Tunnel Junction
    Crisp, Ryan W.
    Pach, Gregory F.
    Kurley, J. Matthew
    France, Ryan M.
    Reese, Matthew O.
    Nanayakkara, Sanjini U.
    MacLeod, Bradley A.
    Talapin, Dmitri V.
    Beard, Matthew C.
    Luther, Joseph M.
    [J]. NANO LETTERS, 2017, 17 (02) : 1020 - 1027
  • [29] Development and characterization of an LED-based detector for dosimetry in diagnostic radiology
    Damulira, Edrine
    Yusoff, Muhammad Nur Salihin
    Omar, Ahmad Fairuz
    Mohd Taib, Nur Hartini
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (08)
  • [30] Application of Bpw34 photodiode and cold white LED as diagnostic X-ray detectors: A comparative analysis
    Damulira, Edrine
    Yusoff, Muhammad Nur Salihin
    Omar, Ahmad Fairuz
    Taib, Nur Hartini Mohd
    Ahmed, Naser M.