摘要
Several methods are proposed in literature to characterize the state of deterioration of water-treed cable insulation. One of these methods is the Return Voltage Measurement (RVM) method, which was initially introduced as a diagnostic method for oil-paper insulating systems. It is mostly used to determine the condition of the paper insulation of transformer windings. It has been shown [1], [2] that it is possible to use RVM for detection of water trees in XLPE cables. In this paper, a methodology is presented that allows the detection of water trees in PE and XLPE insulated cables, without the need for a reference measurement. Also, the influence of temperature on RVM measurements was examined, for cables with and without water trees.
引用
收藏
页码:355 / 358
页数:4
相关论文
共 50 条
  • [31] Study of the voltage behavior of water tree deteriorated XLPE cables by signal current detection mode for insulation diagnosis
    Kakuta, M
    1998 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS, PROCEEDINGS, 1998, : 487 - 490
  • [32] The improved voltage life characteristics of EHV XLPE cables
    Fukui, T
    Hirotsu, K
    Uozumi, T
    IEEE TRANSACTIONS ON POWER DELIVERY, 1999, 14 (01) : 31 - 38
  • [33] Fault Detection and Insulation Damage by Tests on Water Tree-Aged XLPE Cables with Different Voltage.
    Groenefeld, Peter
    Olshausen, Rainer V.
    Selle, Friedrich
    Elektrizitatswirtschaft, 1985, 84 (13): : 501 - 506
  • [34] DETECTION AND LOCATION OF SHEAT FAULTS IN MEDIUM-VOLTAGE CABLES
    JACKLE, E
    ELEKTROTECHNISCHE ZEITSCHRIFT ETZ-A, 1978, 99 (06): : 356 - 358
  • [35] Partial Discharge Detection and Localization along Medium Voltage Cables
    Andrade, M. A.
    Calamera, A.
    Candela, R.
    De Rai, L.
    Imburgia, A.
    Sanseverino, E. Riva
    Romano, P.
    Troia, I.
    Viola, F.
    2017 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENON (CEIDP), 2017, : 389 - 392
  • [36] Reflection characteristics of water treeing insulation in medium voltage cables
    Ye, Yuan
    Hu, Xiao
    PHYSICA SCRIPTA, 2023, 98 (06)
  • [37] Severe Degradation of the Conductor Screen of Service and Laboratory Aged Medium Voltage XLPE Insulated Cables
    Hvidsten, Sverre
    Kvande, Stine
    Ryen, Arve
    Larsen, Per Bjorn
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2009, 16 (01) : 155 - 161
  • [38] Response and mechanisms of water trees in XLPE Cable insulation under superposition voltage
    Zheng, XQ
    Tu, DM
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 517 - 520
  • [39] Proton microprobe analysis of water trees in underground high voltage cables
    Ahmed, M
    Garwan, MA
    Al-Ohali, MA
    Hamouz, Z
    Soufi, K
    Minqin, R
    Rajta, I
    Watt, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 210 : 548 - 553
  • [40] PD diagnosis on medium voltage cables with oscillating voltage (OWTS)
    Petzold, F
    2004 International Conference on Power System Technology - POWERCON, Vols 1 and 2, 2004, : 729 - 735