Experimental study of the swing compressor with two discharge channels for household air-conditioner applications

被引:5
作者
Pan, Xi [1 ]
Pan, Shulin [2 ]
Zhang, Hanyue [1 ]
Xie, Junlong [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, Wuhan 417000, Peoples R China
[2] Hunan Univ Humanities Sci & Technol, Sch Energy & Elect Engn, Loudi 417000, Peoples R China
关键词
Swing compressor; Two discharge channels; Isentropic efficiency; Volumetric efficiency; COP; LEAKAGE CHARACTERISTICS; MODEL; PUMP;
D O I
10.1016/j.ijrefrig.2021.09.024
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, a novel swing compressor with two discharge channels (SCTC) is introduced, which can be an alternative compressor applied in household air-conditioner. SCTC has two discharge ports. The first one without discharge valve operates at all shaft speed and the other one with a high stiffness discharge valve operates at high shaft speed, which is helpful to improve the service life of compressor and discharge valve. Additionally, the discharge close volume is eliminated and the liquid strike can be prevented. In order to obtain the performance of SCTC, a prototype has been tested at three different shaft speeds and its volumetric efficiency, adiabatic efficiency, COP and noise characteristic have been analyzed. The performance of SCTC is always better than that of the swing compressor with no valve (SCNV). Besides, compared with the conventional swing compressor, the COP of SCTC increases by 2.26% at the shaft speed of 1800 r.min(-1).
引用
收藏
页码:56 / 62
页数:7
相关论文
共 40 条
  • [21] Experimental study on electronic expansion valve failure of a R290 room air conditioner during heating-defrosting process
    Du, Yanjun
    Wu, Jianhua
    Che Wang
    Li Jinbo
    APPLIED THERMAL ENGINEERING, 2019, 163
  • [22] An Experimental Study on the Force Coefficient and the Discharge Coefficient of a Safety Valve in Air-water Mixture Flow
    Burhani, Mhd Ghaith
    Hos, Csaba
    PERIODICA POLYTECHNICA-MECHANICAL ENGINEERING, 2021, 65 (04): : 326 - 336
  • [23] Experimental and simulation study of air source heat pump for residential applications in northern China
    Yang, Yongan
    Li, Ruishen
    Zhu, Yiqun
    Sun, Zhili
    Zhang, Zhe
    ENERGY AND BUILDINGS, 2020, 224
  • [24] A preliminary experimental study on atomization rainfall properties by two-jet collision in high dam discharge
    Yuan, Hao
    Sun, Qian
    Hu, Ruichang
    Mao, Yunfei
    Zhou, Xidong
    PHYSICS OF FLUIDS, 2024, 36 (11)
  • [25] Experimental and Numerical Study of Air Vessel in Quasi-Two-Dimensional Transient Flow Analysis
    Kim, Hyunjun
    Choi, Lakwon
    Kim, Sanghyun
    JOURNAL OF PRESSURE VESSEL TECHNOLOGY-TRANSACTIONS OF THE ASME, 2021, 143 (04):
  • [26] An Experimental Study on Air-Water Two-Phase Flow Patterns in Pebble Beds
    Bai Bofeng
    Liu Maolong
    Su Wang
    Zhang Xiaojie
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2010, 132 (04):
  • [27] Earth-to-Air Heat Exchanger for Cooling Applications in a Hot and Dry Climate: Numerical and Experimental Study
    Albarghooth, A.
    Ramiar, A.
    Ramyar, R.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2023, 36 (01): : 78 - 89
  • [28] Experimental study on the two phase flow behavior in PEM fuel cell parallel channels with porous media inserts
    Chen, Jixin
    JOURNAL OF POWER SOURCES, 2010, 195 (04) : 1122 - 1129
  • [29] Experimental Study of Two-Phase Air-Water Flow in Large-Diameter Vertical Pipes
    Ali, S. Farman
    Yeung, H.
    CHEMICAL ENGINEERING COMMUNICATIONS, 2015, 202 (06) : 823 - 842
  • [30] Experimental Study of Two Air Management Strategies for Emissions Control in Heavy Duty Engines at Medium to High Loads
    Bermudez, Vicente
    Molina, Santiago
    Novella, Ricardo
    Estepea, Daniel
    ENERGY & FUELS, 2017, 31 (09) : 10011 - 10022