Development and validation of a sensitive, simple, and rapid method for simultaneous quantitation of atorvastatin and its acid and lactone metabolites by liquid chromatography-tandem mass spectrometry (LC-MS/MS)

被引:38
|
作者
Macwan, Joyce S. [1 ]
Ionita, Ileana A. [1 ]
Dostalek, Miroslav [1 ]
Akhlaghi, Fatemeh [1 ]
机构
[1] Univ Rhode Isl, Dept Biomed & Pharmaceut Sci, Clin Pharmacokinet Res Lab, Kingston, RI 02881 USA
关键词
Assay; Atorvastatin; Concentration; Lactones; LC-MS/MS; Metabolites; Pharmacokinetics; PARA-HYDROXY ATORVASTATIN; HUMAN PLASMA; HUMAN SERUM; INTERNAL STANDARD; REDUCTASE INHIBITOR; UV DETECTION; MS-MS; ASSAY; PRODUCTS; STATINS;
D O I
10.1007/s00216-011-4804-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The aim of the proposed work was to develop and validate a simple and sensitive assay for the analysis of atorvastatin (ATV) acid, ortho- and para-hydroxy-ATV, ATV lactone, and ortho- and para-hydroxy-ATV lactone in human plasma using liquid chromatography-tandem mass spectrometry. All six analytes and corresponding deuterium (d5)-labeled internal standards were extracted from 50 mu L of human plasma by protein precipitation. The chromatographic separation of analytes was achieved using a Zorbax-SB Phenyl column (2.1 mm x 100 mm, 3.5 mu m). The mobile phase consisted of a gradient mixture of 0.1% v/v glacial acetic acid in 10% v/v methanol in water (solvent A) and 40% v/v methanol in acetonitrile (solvent B). All analytes including ortho- and para-hydroxy metabolites were baseline-separated within 7.0 min using a flow rate of 0.35 mL/min. Mass spectrometry detection was carried out in positive electrospray ionization mode, with multiple-reaction monitoring scan. The calibration curves for all analytes were linear (R(2)>= 0.9975, n = 3) over the concentration range of 0.05-100 ng/mL and with lower limit of quantitation of 0.05 ng/mL. Mean extraction recoveries ranged between 88.6-111%. Intra- and inter-run mean percent accuracy were between 85-115% and percent imprecision was <= 15%. Stability studies revealed that ATV acid and lactone forms were stable in plasma during bench top (6 h on ice-water slurry), at the end of three successive freeze and thaw cycles and at -80 degrees C for 3 months. The method was successfully applied in a clinical study to determine concentrations of ATV and its metabolites over 12 h post-dose in patients receiving atorvastatin.
引用
收藏
页码:423 / 433
页数:11
相关论文
共 50 条
  • [41] Validation of a fast and reliable liquid chromatography-tandem mass spectrometry (LC-MS/MS) with atmospheric pressure chemical ionization method for simultaneous quantitation of voriconazole, itraconazole and its active metabolite hydroxyitraconazole in human plasma
    Xiong, Xin
    Zhai, Suodi
    Duan, Jingli
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (02) : 339 - 346
  • [42] Development and Validation of a Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Assay for the Determination of Total and Unbound Ciprofloxacin Concentrations in Human Plasma
    de Vroom, Suzanne L.
    Pistorius, Marcel C. M.
    Bijleveld, Yuma A.
    Geerlings, Suzanne E.
    Mathot, Ron A. A.
    van Hest, Reinier M.
    Jager, Nynke G. L.
    THERAPEUTIC DRUG MONITORING, 2022, 44 (04) : 552 - 557
  • [43] Liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for determination of free and total dabigatran in human plasma and its application to a pharmacokinetic study
    Shaikh, Khurshid
    Mungantiwar, Ashish
    Halde, Supriya
    Pandita, Nancy
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2021, 47 (11) : 1835 - 1846
  • [44] Development and validation of a serum total testosterone liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay calibrated to NIST SRM 971
    French, Deborah
    CLINICA CHIMICA ACTA, 2013, 415 : 109 - 117
  • [45] Simultaneous Determination of 54 Pesticides in Proso Millet Using QuEChERS with Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS)
    Ding, Chao
    Ren, Pengcheng
    Qi, Yanli
    Yang, Yanmei
    Qin, Shu
    MOLECULES, 2023, 28 (18):
  • [46] Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS)-Based Proteomics of Drug-Metabolizing Enzymes and Transporters
    Li, Jiapeng
    Zhu, Hao-Jie
    MOLECULES, 2020, 25 (11):
  • [47] Sensitive Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Analysis of Alkaloid Nitrogen Oxides at Three Different Processing Stages of Binglang
    Pan, Xingyu
    Chen, Jinzi
    Guo, Tao
    Kuang, Fengjiao
    Kang, Zonghua
    Luo, Jianguang
    FOOD ANALYTICAL METHODS, 2024, 17 (11) : 1601 - 1609
  • [48] Simultaneous quantification of cryptotanshinone and its active metabolite tanshinone IIA in plasma by liquid chromatography/tandem mass spectrometry (LC-MS/MS)
    Hao, HP
    Wang, GJ
    Li, P
    Li, J
    Ding, ZQ
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 40 (02) : 382 - 388
  • [49] Development and validation of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) procedure for screening of urine specimens for 100 analytes relevant in drug-facilitated crime (DFC)
    Remane, Daniela
    Wetzel, Diana
    Peters, Frank T.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (18) : 4411 - 4424
  • [50] Novel liquid chromatography tandem mass spectrometry (LC-MS/MS) methods for measuring steroids
    Keevil, Brian G.
    BEST PRACTICE & RESEARCH CLINICAL ENDOCRINOLOGY & METABOLISM, 2013, 27 (05) : 663 - 674