Development and validation of a sensitive, simple, and rapid method for simultaneous quantitation of atorvastatin and its acid and lactone metabolites by liquid chromatography-tandem mass spectrometry (LC-MS/MS)

被引:38
|
作者
Macwan, Joyce S. [1 ]
Ionita, Ileana A. [1 ]
Dostalek, Miroslav [1 ]
Akhlaghi, Fatemeh [1 ]
机构
[1] Univ Rhode Isl, Dept Biomed & Pharmaceut Sci, Clin Pharmacokinet Res Lab, Kingston, RI 02881 USA
关键词
Assay; Atorvastatin; Concentration; Lactones; LC-MS/MS; Metabolites; Pharmacokinetics; PARA-HYDROXY ATORVASTATIN; HUMAN PLASMA; HUMAN SERUM; INTERNAL STANDARD; REDUCTASE INHIBITOR; UV DETECTION; MS-MS; ASSAY; PRODUCTS; STATINS;
D O I
10.1007/s00216-011-4804-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The aim of the proposed work was to develop and validate a simple and sensitive assay for the analysis of atorvastatin (ATV) acid, ortho- and para-hydroxy-ATV, ATV lactone, and ortho- and para-hydroxy-ATV lactone in human plasma using liquid chromatography-tandem mass spectrometry. All six analytes and corresponding deuterium (d5)-labeled internal standards were extracted from 50 mu L of human plasma by protein precipitation. The chromatographic separation of analytes was achieved using a Zorbax-SB Phenyl column (2.1 mm x 100 mm, 3.5 mu m). The mobile phase consisted of a gradient mixture of 0.1% v/v glacial acetic acid in 10% v/v methanol in water (solvent A) and 40% v/v methanol in acetonitrile (solvent B). All analytes including ortho- and para-hydroxy metabolites were baseline-separated within 7.0 min using a flow rate of 0.35 mL/min. Mass spectrometry detection was carried out in positive electrospray ionization mode, with multiple-reaction monitoring scan. The calibration curves for all analytes were linear (R(2)>= 0.9975, n = 3) over the concentration range of 0.05-100 ng/mL and with lower limit of quantitation of 0.05 ng/mL. Mean extraction recoveries ranged between 88.6-111%. Intra- and inter-run mean percent accuracy were between 85-115% and percent imprecision was <= 15%. Stability studies revealed that ATV acid and lactone forms were stable in plasma during bench top (6 h on ice-water slurry), at the end of three successive freeze and thaw cycles and at -80 degrees C for 3 months. The method was successfully applied in a clinical study to determine concentrations of ATV and its metabolites over 12 h post-dose in patients receiving atorvastatin.
引用
收藏
页码:423 / 433
页数:11
相关论文
共 50 条
  • [1] Development and validation of a sensitive, simple, and rapid method for simultaneous quantitation of atorvastatin and its acid and lactone metabolites by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Joyce S. Macwan
    Ileana A. Ionita
    Miroslav Dostalek
    Fatemeh Akhlaghi
    Analytical and Bioanalytical Chemistry, 2011, 400 : 423 - 433
  • [2] A simple assay for the simultaneous determination of rosuvastatin acid, rosuvastatin-5S-lactone, and N-desmethyl rosuvastatin in human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Macwan, Joyce S.
    Ionita, Ileana A.
    Akhlaghi, Fatemeh
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (03) : 1217 - 1227
  • [3] A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the estimation of rivastigmine in human plasma
    Bhatt, Jignesh
    Subbaiah, Gunta
    Kambli, Sandeep
    Shah, Bhavin
    Nigam, Samita
    Patel, Mehul
    Saxena, Ashish
    Baliga, Ashok
    Parekh, Hetal
    Yadav, Gunvat
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 115 - 121
  • [4] A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the estimation of amlodipine in human plasma
    Bhatt, Jignesh
    Singh, Sadhana
    Subbaiah, Gunta
    Shah, Bhavin
    Kambli, Sandeep
    Ameta, Suresh
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (02) : 169 - 175
  • [5] Development and validation of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay to quantify serum voriconazole
    Mak, Justin
    Sujishi, Kirk K.
    French, Deborah
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 986 : 94 - 99
  • [6] Development and validation of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of tigecycline in rat brain tissues
    Munyeza, Chiedza F.
    Shobo, Adeola
    Baijnath, Sooraj
    Bratkowska, Dominika
    Naiker, Suhashni
    Bester, Linda A.
    Singh, Sanil D.
    Maguire, Glenn E. M.
    Kruger, Hendrik G.
    Naicker, Tricia
    Govender, Thavendran
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (06) : 837 - 845
  • [7] Development and validation of a sensitive LC-MS/MS method for the simultaneous quantitation of theophylline and its metabolites in rat plasma
    Chae, Jung-woo
    Kim, Dong-hyun
    Lee, Byung-yo
    Kim, Eun Jung
    Kwon, Kwang-il
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 889 : 44 - 49
  • [8] The Development of a Highly Sensitive Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Method for the Validation of Flualprazolam and Isotonitazene in Serum
    Akbaba, Murat
    Isir, Aysun Baransel
    APPLIED SCIENCES-BASEL, 2025, 15 (05):
  • [9] Rapid and sensitive method for the determination of sertraline in human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Jain, DS
    Sanyal, M
    Subbaiah, G
    Pande, UC
    Shrivastav, P
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 829 (1-2): : 69 - 74
  • [10] Rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of clonidine in human plasma
    Parekh, Sagar A.
    Pudage, Ashutosh
    Joshi, Santosh S.
    Vaidya, Vilas V.
    Gomes, Noel A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 867 (02): : 172 - 178