Liquid crystal heat transfer measurements in a rectangular channel with solid and slit rib

被引:16
|
作者
Panigrahi, PK [1 ]
Tariq, A [1 ]
机构
[1] Indian Inst Technol, Mech Engn Dept, Kanpur 208016, Uttar Pradesh, India
关键词
heat transfer enhancement; solid rib; slit rib; entropy generation; liquid crystal thermography;
D O I
10.1007/BF03181747
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
An experimental investigation on the heat transfer effectiveness of solid and slit ribs mounted on the bottom surface of a rectangular channel has been carried out at Reynolds numbers of 13400, 22600, 32100 and 40800. The rib height to hydraulic diameter ratio (e/D-h) set during experiment is equal to 0.0624. The surface Nusselt number results from transient liquid crystal thermography are presented. The heat transfer enhancement performance analysis has been carried out using entropy generation principle. The slit rib is superior to solid rib from both heat transfer augmentation and pressure penalty point of view. The performance of the slit rib is a function of the open area ratio (beta) and the location of the slit W from the bottom test surface. The optimum open area ratio is 20% and the slit located symmetrically from the top and bottom surface of the rib is the optimum location of the slit. The heat transfer augmentation of the slit rib (beta = 20%) is 61% in comparison to 40% for the solid rib at Re = 32100 and the pressure penalty for the slit rib is 7% lower than the solid rib. The entropy generation for the slit rib is 33% less than that of the solid rib.
引用
收藏
页码:407 / 416
页数:10
相关论文
共 50 条
  • [1] Liquid crystal heat transfer measurements in a rectangular channel with solid and slit rib
    P. K. Panigrahi
    A. Tariq
    Journal of Visualization, 2003, 6 : 407 - 416
  • [2] Heat transfer augmentation in a rectangular channel with slit rib-turbulators on two opposite walls
    Department of Mechanical Engineering, Chung-Hua Polytechnic Institute, Hsinchu, 30067, Taiwan
    不详
    Journal of Turbomachinery, 1997, 119 (03): : 617 - 623
  • [3] Heat transfer augmentation in a rectangular channel with slit rib-turbulators on two opposite walls
    Hwang, JJ
    Liou, TM
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1997, 119 (03): : 617 - 623
  • [4] MULTIOBJECTIVE OPTIMIZATION OF A SLIT RIB IN A RECTANGULAR COOLING CHANNEL
    Jeong, Han-Sol
    Seo, Jae-Won
    Kim, Kwang-Yong
    HEAT TRANSFER RESEARCH, 2018, 49 (05) : 395 - 412
  • [5] Heat transfer measurement in rectangular channel with detach ribs by liquid crystal thermography
    Gharai, Sibendra Kumar
    Layek, Apurba
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2018, 36 (04) : 1502 - 1509
  • [6] The flow and heat transfer characteristics in a rectangular channel with convergent and divergent slit ribs
    Zheng, Daren
    Wang, Xinjun
    Yuan, Qi
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 141 : 464 - 475
  • [7] Effect of Entrance Geometry on Heat Transfer in a Rib-Roughened Rectangular Channel
    Satta, Francesca
    Tanda, Giovanni
    Venturino, Giulio
    HEAT TRANSFER ENGINEERING, 2022, 43 (07) : 623 - 637
  • [8] CHARACTERISTICS OF TURBULENT FLOW AND HEAT TRANSFER IN A RECTANGULAR CHANNEL WITH REPEATED RIB ROUGHNESS
    Sato, Hiroshi
    Hishida, Koichi
    Maedo, Masanobu
    EXPERIMENTAL HEAT TRANSFER, 1992, 5 (01) : 1 - 16
  • [9] EFFECT OF SEMI-CIRCLE RIB ON HEAT TRANSFER COEFFICIENT IN A RECTANGULAR CHANNEL
    Al-Turaihi, Riyadh S.
    Fadhil, Doaa
    Abed, Azher M.
    FRONTIERS IN HEAT AND MASS TRANSFER, 2019, 13
  • [10] Heat transfer and pressure drop measurements in rib-roughened rectangular ducts
    Gao, XF
    Sundén, B