Experimental Study of Perfobond Rib Shear Connector under Lateral Force

被引:4
|
作者
Wang, Xuewei [1 ]
He, Qiuxia [1 ]
An, Zhiwen [1 ]
Liu, Guojun [1 ]
Wen, Xingke [1 ]
Wang, Yongqiang [1 ]
Zhong, Zhenxiao [1 ]
机构
[1] Sichuan Agr Univ, Sch Civil Engn, Chengdu 611830, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 19期
关键词
Perfobond rib shear connector; experimental study; push-out tests; lateral force; SEMIRIGID COMPOSITE FRAMES; STEEL; BEHAVIOR; RESISTANCE; STRENGTH; GIRDERS;
D O I
10.3390/app11199088
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A series of full-scale pushed out tests were performed on the Perfobond rib shear connector. The tests were designed to examine the performance of the Perfobond rib shear connector under different rib hole sizes and shapes, reinforcing bar sizes, rib thicknesses, as well as the presence of lateral forces. It has been revealed from the test results that the rib hole size and reinforcement diameter may not act independently, and the influence of one's size is actually dependent on the size of the other one. The lateral forces also affect the performance of the shear connector; for example, the capacity of the shear connector would be larger under compression than under tension. The existence of transverse pretension stress accelerated the cracking of concrete, leading to the strength and stiffness of concrete, perforated plate, and reinforcing rebars unable to fully exert their effect. In addition, the constraint effect of transverse stress improved the strength and stiffness of concrete and delayed the concrete cracking, bringing the strength and stiffness of concrete, perforated plate, and reinforcing rebars into full play, and resulting in a significant improvement in the shear capacity of Perfobond rib shear connectors.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Shear resistance of the perfobond-rib shear connector depending on concrete strength and rib arrangement
    Ahn, Jin-Hee
    Lee, Chan-Goo
    Won, Jeong-Hun
    Kim, Sang-Hyo
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (10) : 1295 - 1307
  • [2] Theoretical and Experimental Studies of the Internal Force Transfer Mechanism of Perfobond Rib Shear Connector Group
    Zhang, Qinghua
    Pei, Shiling
    Cheng, Zhenyu
    Bao, Yi
    Li, Qiao
    JOURNAL OF BRIDGE ENGINEERING, 2017, 22 (02)
  • [3] Experimental and analytical study on shear mechanism of rubber-ring perfobond connector
    Liu, Yangqing
    Xin, Haohui
    Liu, Yuqing
    ENGINEERING STRUCTURES, 2019, 197
  • [4] Predicting the capacity of perfobond rib shear connector using an ANN model and GSA method
    Sun, Guorui
    Shi, Jun
    Deng, Yuang
    FRONTIERS OF STRUCTURAL AND CIVIL ENGINEERING, 2022, 16 (10) : 1233 - 1248
  • [5] Experimental shear resistance evaluation of Y-type perfobond rib shear connector
    Kim, Sang-Hyo
    Choi, Kyu-Tae
    Park, Se-Jun
    Park, Seung-Min
    Lung, Chi-Young
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2013, 82 : 1 - 18
  • [6] Bearing mechanisms of perfobond rib shear connectors by experimental investigation
    Meng, Hao
    Xu, Rongqiao
    ENGINEERING STRUCTURES, 2025, 326
  • [7] Shear Behavior of Y-Shaped Perfobond Rib Shear Connector with UHPC Grout
    Ni, Yulong
    Hu, Menghan
    Jia, Zhenlei
    Han, Qiang
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (09)
  • [8] Experimental and Numerical Study on Shear Resistance of Notched Perfobond Shear Connector
    Zheng, Shuangjie
    Liu, Yuqing
    Liu, Yangqing
    Zhao, Chen
    MATERIALS, 2019, 12 (03)
  • [9] Experimental research on bearing mechanism of perfobond rib shear connectors
    Su, Qing-Tian
    Wang, Wei
    Luan, Hai-Wen
    Yang, Guo-Tao
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 95 : 22 - 31
  • [10] Experimental investigation on the bearing mechanism of Perfobond rib shear connectors
    Zhao, Canhui
    Li, Zhixiang
    Deng, Kailai
    Wang, Weian
    ENGINEERING STRUCTURES, 2018, 159 : 172 - 184