Machine Perfusion of Donor Livers for Transplantation: A Proposal for Standardized Nomenclature and Reporting Guidelines

被引:106
作者
Karangwa, S. A. [1 ,2 ]
Dutkowski, P. [3 ]
Fontes, P. [4 ,5 ]
Friend, P. J. [6 ]
Guarrera, J. V. [7 ]
Markmann, J. F. [8 ]
Mergental, H. [9 ]
Minor, T. [10 ]
Quintini, C. [11 ]
Selzner, M. [12 ]
Uygun, K. [13 ]
Watson, C. J. [14 ,15 ]
Porte, R. J. [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Surg, Sect Hepatobiliary Surg & Liver Transplantat, Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Surg Res Lab, Groningen, Netherlands
[3] Univ Zurich Hosp, Dept Surg & Transplantat, Zurich, Switzerland
[4] Univ Pittsburgh, Med Ctr, Dept Surg, Thomas E Starzl Transplantat Inst, Pittsburgh, PA USA
[5] Univ Pittsburgh, McGowan Inst Regenerat Med, Pittsburgh, PA USA
[6] Univ Oxford, Churchill Hosp, Oxford Transplant Ctr, Nuffield Dept Surg, Oxford, England
[7] Columbia Univ, Med Ctr, Dept Surg, Ctr Liver Dis & Transplantat, New York, NY USA
[8] Massachusetts Gen Hosp, Transplant Ctr, Boston, MA 02114 USA
[9] Univ Hosp Birmingham, Liver Unit, Birmingham, W Midlands, England
[10] Univ Hosp Essen, Clin Gen Visceral & Transplantat Surg, Dept Surg Res, Essen, Germany
[11] Cleveland Clin Fdn, Inst Digest Dis, Dept Surg, Transplant Ctr, 9500 Euclid Ave, Cleveland, OH 44195 USA
[12] Toronto Gen Hosp, Multi Organ Transplant Program, Dept Surg, Toronto, ON, Canada
[13] Harvard Med Sch, Massachusetts Gen Hosp, Dept Surg, Ctr Engn Med, Boston, MA USA
[14] Univ Cambridge, Dept Surg, Cambridge, England
[15] Univ Cambridge, Addenbrookes Hosp, NIHR Blood & Transplant Res Unit Organ Donat & Tr, Cambridge, England
关键词
HEART-BEATING DONORS; BILE-DUCT INJURY; SEQUENTIAL COLD-STORAGE; WARM ISCHEMIC-INJURY; EX-VIVO; RAT-LIVER; CARDIAC DEATH; NORMOTHERMIC PERFUSION; ENDOTHELIAL-CELL; DCD LIVERS;
D O I
10.1111/ajt.13843
中图分类号
R61 [外科手术学];
学科分类号
摘要
With increasing demand for donor organs for transplantation, machine perfusion (MP) promises to be a beneficial alternative preservation method for donor livers, particularly those considered to be of suboptimal quality, also known as extended criteria donor livers. Over the last decade, numerous studies researching MP of donor livers have been published and incredible advances have been made in both experimental and clinical research in this area. With numerous research groups working on MP, various techniques are being explored, often applying different nomenclature. The objective of this review is to catalog the differences observed in the nomenclature used in the current literature to denote various MP techniques and the manner in which methodology is reported. From this analysis, we propose a standardization of nomenclature on liver MP to maximize consistency and to enable reliable comparison and meta-analyses of studies. In addition, we propose a standardized set of guidelines for reporting the methodology of future studies on liver MP that will facilitate comparison as well as clinical implementation of liver MP procedures.
引用
收藏
页码:2932 / 2942
页数:11
相关论文
共 126 条
  • [81] Metabolic preconditioning of donor organs: Defatting fatty livers by normothermic perfusion ex vivo
    Nagrath, Deepak
    Xu, Hongzhi
    Tanimura, Yoko
    Zuo, Rongjun
    Berthiaume, Francois
    Avila, Marco
    Yarmush, Rubin
    Yarmush, Martin L.
    [J]. METABOLIC ENGINEERING, 2009, 11 (4-5) : 274 - 283
  • [82] Ex Vivo Normothermic Machine Perfusion Is Safe, Simple, and Reliable: Results From a Large Animal Model
    Nassar, Ahmed
    Liu, Qiang
    Farias, Kevin
    D'Amico, Giuseppe
    Tom, Cynthia
    Grady, Patrick
    Bennett, Ana
    Uso, Teresa Diago
    Eghtesad, Bijan
    Kelly, Dympna
    Fung, John
    Abu-Elmagd, Kareem
    Miller, Charles
    Quintini, Cristiano
    [J]. SURGICAL INNOVATION, 2015, 22 (01) : 61 - 69
  • [83] Temperature-induced differential kinetic properties between an initial burst and the following steady state in membrane-bound enzymes: Studies on lathosterol 5-desaturase
    Nishino, H
    Nakaya, J
    Nishi, S
    Kurosawa, T
    Ishibashi, T
    [J]. ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1997, 339 (02) : 298 - 304
  • [84] Temperature Controlled Machine Perfusion System for Liver
    Obara, H.
    Matsuno, N.
    Shigeta, T.
    Hirano, T.
    Enosawa, S.
    Mizunuma, H.
    [J]. TRANSPLANTATION PROCEEDINGS, 2013, 45 (05) : 1690 - 1692
  • [85] Pretransplant Screening and Evaluation of Liver Graft Viability Using Machine Perfusion Preservation in Porcine Transplantation
    Obara, H.
    Matsuno, N.
    Enosawa, S.
    Shigeta, T.
    Huai-Che, H.
    Hirano, T.
    Muto, M.
    Kasahara, M.
    Uemoto, S.
    Mizunuma, H.
    [J]. TRANSPLANTATION PROCEEDINGS, 2012, 44 (04) : 959 - 961
  • [86] Use of HTK solution for hypothermic machine perfusion: An alternative for the preservation of less than optimal donor livers? An experimental study in rats
    Olschewski, P
    Tolba, R
    Akbar, S
    Minor, T
    [J]. TRANSPLANTATION PROCEEDINGS, 2003, 35 (02) : 767 - 767
  • [87] Normothermic Machine Perfusion of Discarded Liver Grafts
    op den Dries, S.
    Karimian, N.
    Porte, R. J.
    [J]. AMERICAN JOURNAL OF TRANSPLANTATION, 2013, 13 (09) : 2504 - 2504
  • [88] op den Dries S, 2013, AM J TRANSPLANT, V13, P519
  • [89] Ex vivo Normothermic Machine Perfusion and Viability Testing of Discarded Human Donor Livers
    op den Dries, S.
    Karimian, N.
    Sutton, M. E.
    Westerkamp, A. C.
    Nijsten, M. W. N.
    Gouw, A. S. H.
    Wiersema-Buist, J.
    Lisman, T.
    Leuvenink, H. G. D.
    Porte, R. J.
    [J]. AMERICAN JOURNAL OF TRANSPLANTATION, 2013, 13 (05) : 1327 - 1335
  • [90] op den Dries S, 2012, HPB, V14, P482