Importance of the grayscale in early assessment of image quality gains with iterative CT reconstruction

被引:0
作者
Noo, F. [1 ]
Hahn, K. [1 ,2 ]
Guo, Z. [1 ]
机构
[1] Univ Utah, Dept Radiol & Imaging Sci, Salt Lake City, UT 84112 USA
[2] Siemens Healthcare GmbH, Forchheim, Germany
来源
MEDICAL IMAGING 2016: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT | 2016年 / 9787卷
关键词
STANDARD;
D O I
10.1117/12.2217689
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Iterative reconstruction methods have become an important research topic in X-ray computed tomography (CT), due to their ability to yield improvements in image quality in comparison with the classical filtered bacprojection method. There are many ways to design an effective iterative reconstruction method. Moreover, for each design, there may be a large number of parameters that can be adjusted. Thus, early assessment of image quality, before clinical deployment, plays a large role in identifying and refining solutions. Currently, there are few publications reporting on early, task-based assessment of image quality achieved with iterative reconstruction methods. We report here on such an assessment, and we illustrate at the same time the importance of the grayscale used for image display when conducting this type of assessment. Our results further support observations made by others that the edge preserving penalty term used in iterative reconstruction is a key ingredient to improving image quality in terms of detection task. Our results also provide a clear demonstration of an implication made in one of our previous publications, namely that the grayscale window plays an important role in image quality comparisons involving iterative CT reconstruction methods.
引用
收藏
页数:6
相关论文
共 8 条
  • [1] Evaluation of multiclass model observers in PET LROC studies
    Gifford, H. C.
    Kinahan, P. E.
    Lartizien, C.
    King, M. A.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (01) : 116 - 123
  • [2] Kadrmas D. J., 2009, MED IMAGING IEEE T, V28, P523
  • [3] Achieving Routine Submillisievert CT Scanning: Report from the Summit on Management of Radiation Dose in CT
    McCollough, Cynthia H.
    Chen, Guang Hong
    Kalender, Willi
    Leng, Shuai
    Samei, Ehsan
    Taguchi, Katsuyuki
    Wang, Ge
    Yu, Lifeng
    Pettigrew, Roderic I.
    [J]. RADIOLOGY, 2012, 264 (02) : 567 - 580
  • [4] Noo F., 2015, SPIE MED IMAGING
  • [5] ACR-AAPM-SIIM Technical Standard for Electronic Practice of Medical Imaging
    Norweck, James T.
    Seibert, J. Anthony
    Andriole, Katherine P.
    Clunie, David A.
    Curran, Bruce H.
    Flynn, Michael J.
    Krupinski, Elizabeth
    Lieto, Ralph P.
    Peck, Donald J.
    Mian, Tariq A.
    [J]. JOURNAL OF DIGITAL IMAGING, 2013, 26 (01) : 38 - 52
  • [6] Abdominal CT With Model-Based Iterative Reconstruction (MBIR): Initial Results of a Prospective Trial Comparing Ultralow-Dose With Standard-Dose Imaging
    Pickhardt, Perry J.
    Lubner, Meghan G.
    Kim, David H.
    Tang, Jie
    Ruma, Julie A.
    del Rio, Alejandro Munoz
    Chen, Guang-Hong
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (06) : 1266 - 1274
  • [7] Image Comparative Assessment Using Iterative Reconstructions Clinical Comparison of Low-Dose Abdominal/Pelvic Computed Tomography Between Adaptive Statistical, Model-Based Iterative Reconstructions and Traditional Filtered Back Projection in 65 Patients
    Vardhanabhuti, Varut
    Riordan, Richard D.
    Mitchell, Grant R.
    Hyde, Christopher
    Roobottom, Carl A.
    [J]. INVESTIGATIVE RADIOLOGY, 2014, 49 (04) : 209 - 216
  • [8] Comparison of image quality between filtered back-projection and the adaptive statistical and novel model-based iterative reconstruction techniques in abdominal CT for renal calculi
    Vardhanabhuti V.
    Ilyas S.
    Gutteridge C.
    Freeman S.J.
    Roobottom C.A.
    [J]. Insights into Imaging, 2013, 4 (5) : 661 - 669