Determination of N-Nitrosamines by Gas Chromatography Coupled to Quadrupole-Time-of-Flight Mass Spectrometry in Water Samples

被引:19
|
作者
Jose Sieira, Benigno [1 ]
Carpinteiro, Inmaculada [1 ]
Rodil, Rosario [1 ]
Benito Quintana, Jose [1 ]
Cela, Rafael [1 ]
机构
[1] Univ Santiago de Compostela, Inst Food Anal & Res IIAA, Dept Analyt Chem Nutr & Food Sci, R Constantino Candeira S-N, Santiago De Compostela 15782, Spain
关键词
gas chromatography-mass spectrometry (GC-MS); high-resolution mass spectrometry (HRMS); N-nitrosamines; water samples; positive chemical ionization (PCI); SOLID-PHASE MICROEXTRACTION; DRINKING-WATER; NITROSODIMETHYLAMINE NDMA; CHEMICAL-IONIZATION; CHLORAMINATION; CHLORINATION; PRECURSORS; MS;
D O I
10.3390/separations7010003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical method based on high-resolution quadrupole-time-of-flight (QToF) mass spectrometry has been developed as an alternative to the classical method, using a low-resolution ion trap (IT) analyzer to reduce interferences in N-nitrosamines determination. Extraction of the targeted compounds was performed by solid-phase extraction (SPE) following the United States Environmental Protection Agency (USEPA) -521 method. First, both electron impact (EI) and positive chemical ionization (PCI) using methane as ionization gas were compared, along with IT and QToF detection. Then, parameters such as limits of detection (LOD) and quantification (LOQ), linearity, and repeatability were assessed. The results showed that the QToF mass analyzer combined with PCI was the best system for the determination of the N-nitrosamines, with instrumental LOD and LOQ in the ranges of 0.2-4 and 0.6-11 ng mL(-1), respectively, which translated into method LOD and LOQ in the ranges of 0.2-1.3 and 0.6-3.9 ng L-1, respectively. The analysis of real samples showed the presence of 6 of the N-nitrosamines in influent, effluent, and tap water. N-nitrosodimethylamine (NDMA) was quantified in all the analyzed samples at concentrations between 1 and 27 ng L-1. Moreover, four additional nitrosamines were found in tap and wastewater samples.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Determination of N-nitrosamines in processed meats by liquid extraction combined with gas chromatography-methanol chemical ionisation/mass spectrometry
    Scheeren, Marina Bergoli
    Sabik, Hassan
    Gariepy, Claude
    Terra, Nelcindo Nascimento
    Arul, Joseph
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2015, 32 (09): : 1436 - 1447
  • [22] Multi-determination of organic pollutants in water by gas chromatography coupled to triple quadrupole mass spectrometry
    Retamal, Mauricio
    Costa, Christian
    Suarez, Juan M.
    Richter, Pablo
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2013, 93 (01) : 93 - 107
  • [23] Analysis of 100 pharmaceuticals and their degradates in water samples by liquid chromatography/quadrupole time-of-flight mass spectrometry
    Ferrer, Imma
    Thurman, E. Michael
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1259 : 148 - 157
  • [24] A novel molecularly imprinted polymer-solid phase extraction method coupled with high performance liquid chromatography tandem mass spectrometry for the determination of nitrosamines in water and beverage samples
    Li, Zhigang
    Wang, Junjie
    Chen, Xiao
    Hu, Shaoyang
    Gong, Tingting
    Xian, Qiming
    FOOD CHEMISTRY, 2019, 292 : 267 - 274
  • [25] Liquid chromatography-tandem mass spectrometry determination of N-nitrosamines released from rubber or elastomer teats and soothers
    Sung, J. H.
    Kwak, I. S.
    Park, S. K.
    Kim, H. I.
    Lim, H. S.
    Park, H. J.
    Kim, S. H.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2010, 27 (12): : 1745 - 1754
  • [26] Liquid chromatography-quadrupole-time-of-flight mass spectrometry screening procedure for urine samples in forensic casework compared to gas chromatography-mass spectrometry
    Fels, Helena
    Dame, Torsten
    Sachs, Hans
    Musshoff, Frank
    DRUG TESTING AND ANALYSIS, 2017, 9 (05) : 824 - 830
  • [27] Molecularly imprinted solid phase extraction coupled with gas chromatography-mass spectrometry for determination of N-Nitrosodiphenylamine in water samples
    Li, Zhigang
    Qian, Zongyao
    Hu, Shaoyang
    Gong, Tingting
    Xian, Qiming
    CHEMOSPHERE, 2018, 212 : 872 - 880
  • [28] Rapid Determination of Parabens in Water Samples by Ultra-high Performance Liquid Chromatography Coupled to Time of Flight Mass Spectrometry
    Mercedes Becerra-Herrera
    Valentina Miranda
    Pablo Richter
    Analytical Sciences, 2020, 36 : 675 - 679
  • [29] Rapid Determination of Parabens in Water Samples by Ultra-high Performance Liquid Chromatography Coupled to Time of Flight Mass Spectrometry
    Becerra-Herrera, Mercedes
    Miranda, Valentina
    Richter, Pablo
    ANALYTICAL SCIENCES, 2020, 36 (06) : 675 - 679
  • [30] Determination of nine volatile N-nitrosamines in tobacco and smokeless tobacco products by dispersive solid-phase extraction with gas chromatography and tandem mass spectrometry
    Lv, Fang
    Guo, Junwei
    Yu, Fei
    Zhang, Tingting
    Zhang, Shimin
    Cui, Huapeng
    Liu, Xianjun
    Chen, Li
    Liu, Leiyu
    Liu, Shaofeng
    Xie, Fuwei
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (11) : 2123 - 2128