摘要
Absolute calibration of radiometers is implemented onboard using one hot and one cold external calibration targets. However, two-point calibration methods are unable to differentiate calibration drifts and associated errors from fluctuations in receiver gain and offset. This paper investigates the use of onboard three-point calibration algorithm for microwave radiometers to track calibration drifts and characterize associated errors in Earth and Space measurements of the radiometer.
引用
收藏
页码:147 / 150
页数:4
相关论文
共 50 条
  • [1] A Preliminary Study of Three-Point Onboard External Calibration for Tracking Radiometric Stability and Accuracy
    Aksoy, Mustafa
    Racette, Paul E.
    REMOTE SENSING, 2019, 11 (23)
  • [2] TRACKING CALIBRATION STABILITY IN CLIMATE MONITORING MICROWAVE RADIOMETERS USING ONBOARD 3-POINT CALIBRATION
    Aksoy, Mustafa
    Racette, Paul E.
    2017 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2017, : 2118 - 2120
  • [3] One-Point Microwave Radiometer Calibration
    Corbella, Ignasi
    Tones, Francesc
    Closa, Josep
    Duffo, Nuria
    Duran, Israel
    Gonzalez-Gambau, Veronica
    Martin-Neira, Manuel
    IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2020, 17 (03) : 461 - 463
  • [4] Fast Calibration Method for Base Coordinates of the Dual-Robot Based on Three-Point Measurement Calibration Method
    Mao, Jincheng
    Xu, Ruidi
    Ma, Xiaojie
    Hu, Shun
    Bao, Xiulan
    APPLIED SCIENCES-BASEL, 2023, 13 (15):
  • [5] MICROWAVE RADIOMETER INTER-CALIBRATION USING THE VICARIOUS CALIBRATION METHOD
    McKague, Darren
    Ruf, Chris
    Puckett, John J.
    2009 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS 1-5, 2009, : 2497 - 2500
  • [6] Microwave Radiometer Calibration Using Low-Noise Amplifier as Calibration Source
    Neate, Reuben
    Stander, Tinus
    IEEE MICROWAVE AND WIRELESS TECHNOLOGY LETTERS, 2025, 35 (01): : 127 - 130
  • [7] SMAP MICROWAVE RADIOMETER: INSTRUMENT STATUS AND CALIBRATION FOR THE FIRST THREE YEARS OF OPERATION
    Piepmeier, Jeffrey R.
    Peng, Jinzheng
    Misra, Sidharth
    Dinnat, Emmanuel P.
    Yueh, Simon H.
    Meissner, Thomas
    Le Vine, David M.
    Shelton, Kacie E.
    Freedman, Adam P.
    Dunbar, R. Scott
    Chan, Steven K.
    Chaubell, Julian
    Bindlish, Rajat
    De Amici, Giovanni
    Mohammed, Priscilla N.
    Hong, Liang
    IGARSS 2018 - 2018 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, 2018, : 3751 - 3753
  • [8] Research on calibration method of three band infrared integrated radiometer
    Wang, X
    Gao, ZY
    Zhang, JY
    Jin, WQ
    OPTICAL DESIGN AND TESTING, 2002, 4927 : 133 - 138
  • [9] Error analysis and accuracy validation of two-point calibration for microwave radiometer receiver
    Luan Hui
    Zhao Kai
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2007, 26 (04) : 289 - 292
  • [10] Stability and absolute stability of a three-point difference scheme
    Chernyavskaya, NA
    COMPUTERS & MATHEMATICS WITH APPLICATIONS, 2003, 45 (6-9) : 1181 - 1194