Impact of improved spatial resolution on radiomic features using photon-counting-detector CT

被引:18
|
作者
Dunning, Chelsea A. S. [1 ]
Rajendran, Kishore [1 ]
Fletcher, Joel G. [1 ]
McCollough, Cynthia H. [1 ]
Leng, Shuai [1 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
来源
MEDICAL IMAGING 2022: IMAGE PROCESSING | 2022年 / 12032卷
关键词
radiomics; x-ray computed tomography; spatial resolution; image segmentation; noise measurement; SYSTEM;
D O I
10.1117/12.2612229
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Radiomics is a promising mathematical tool for characterizing disease and predicting clinical outcomes from radiological images such as CT. Photon-counting-detector (PCD) CT provides improved spatial resolution and dose efficiency relative to conventional energy-integrating-detector CT systems. Since improved spatial resolution enables visualization of smaller structures and more details that are not typically visible at routine resolution, it has a direct impact on textural features in CT images. Therefore, it is of clinical interest to quantify the impact of the improved spatial resolution on calculated radiomic features and, consequently, on sample classification. In this work, organic samples (zucchini, onions, and oranges) were scanned on both clinical PCD-CT and EID- CT systems at two dose levels. High-resolution PCD-CT and routine-resolution EID-CT images were reconstructed using a dedicated sharp kernel and a routine kernel, respectively. The noise in each image was quantified. Fourteen radiomic features of relevance were calculated in each image for each sample and compared between the two scanners. Radiomic features were plotted pairwise to evaluate the resulting cluster separation of the samples by their type between PCD-CT and EID-CT. Thirteen out of 14 studied radiomic features were notably changed by the improved resolution of the PCD-CT system, and the cluster separation was better when assessing features derived from PCD-CT. These results show that features derived from high-resolution PCD-CT, which are subject to higher noise compared to EID-CT, may impact radiomics-based clinical decision making.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Diagnosis of acute pulmonary embolism: when photon-counting-detector CT replaces energy-integrating-detector CT in daily routine
    Remy-Jardin, Martine
    Oufriche, Idir
    Guiffault, Lucas
    Duhamel, Alain
    Flohr, Thomas
    Schmidt, Bernhard
    Remy, Jacques
    EUROPEAN RADIOLOGY, 2024, : 6544 - 6555
  • [22] Improved Structure Visibility in Temporal Bone Images with Photon Counting Detector CT Using a Super Resolution Neural Network
    Koons, E.
    Chang, S.
    Gong, H.
    McCollough, C. H.
    Leng, S.
    MEDICAL PHYSICS, 2024, 51 (10) : 7714 - 7715
  • [23] Performance evaluation of single- and dual-contrast spectral imaging on a photon-counting-detector CT
    Ren, Liqiang
    Zhou, Zhongxing
    Ahmed, Zaki
    Rajendran, Kishore
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Yu, Lifeng
    MEDICAL PHYSICS, 2024, 51 (11) : 8034 - 8046
  • [24] High-pitch, high temporal resolution, multi-energy cardiac imaging on a dual-source photon-counting-detector CT
    Ahmed, Zaki
    Campeau, David
    Gong, Hao
    Rajendran, Kishore
    Rajiah, Prabhakar
    McCollough, Cynthia
    Leng, Shuai
    MEDICAL PHYSICS, 2023, 50 (03) : 1428 - 1435
  • [25] Radiation dose efficiency of multi-energy photon-counting-detector CT for dual-contrast imaging
    Ren, Liqiang
    Rajendran, Kishore
    McCollough, Cynthia H.
    Yu, Lifeng
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (24):
  • [26] Ultra-High-Resolution Temporal Bone Anatomy Using Photon-counting CT: Added Value of Improved Spatial Resolution
    Ansari, Shehbaz
    Jhaveri, Miral D.
    Suthar, Pokhraj Prakashchandra
    DeSanto, Jeffrey
    Gaddikeri, Santhosh
    Vattoth, Surjith
    RADIOGRAPHICS, 2024, 44 (10)
  • [27] Image quality of lung perfusion with photon-counting-detector CT: comparison with dual-source, dual-energy CT
    Remy-Jardin, Martine
    Guiffault, Lucas
    Oufriche, Idir
    Duhamel, Alain
    Flohr, Thomas
    Schmidt, Bernhard
    Remy, Jacques
    EUROPEAN RADIOLOGY, 2024, 34 (12) : 7831 - 7844
  • [28] Improvement of spatial resolution in a Timepix based CdTe photon counting detector using ToT method
    Park, Kyeongjin
    Lee, Daehee
    Lim, Kyung Taek
    Kim, Giyoon
    Chang, Hojong
    Yi, Yun
    Cho, Gyuseong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 891 : 18 - 24
  • [29] Coronary artery stenosis quantification in patients with dense calcifications using ultra-high-resolution photon-counting-detector computed tomography
    Koons, Emily K.
    Rajiah, Prabhakar Shantha
    Thorne, Jamison E.
    Weber, Nikkole M.
    Kasten, Holly J.
    Shanblatt, Elisabeth R.
    Mccollough, Cynthia H.
    Leng, Shuai
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2024, 18 (01) : 56 - 61
  • [30] Optimal Virtual Monoenergetic Photon Energy (keV) for Photon-Counting-Detector Computed Tomography Angiography
    Dunning, Chelsea A. S.
    Rajendran, Kishore
    Inoue, Akitoshi
    Rajiah, Prabhakar
    Weber, Nikkole
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Leng, Shuai
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2023, 47 (04) : 569 - 575