Impact of improved spatial resolution on radiomic features using photon-counting-detector CT

被引:18
|
作者
Dunning, Chelsea A. S. [1 ]
Rajendran, Kishore [1 ]
Fletcher, Joel G. [1 ]
McCollough, Cynthia H. [1 ]
Leng, Shuai [1 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
来源
MEDICAL IMAGING 2022: IMAGE PROCESSING | 2022年 / 12032卷
关键词
radiomics; x-ray computed tomography; spatial resolution; image segmentation; noise measurement; SYSTEM;
D O I
10.1117/12.2612229
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Radiomics is a promising mathematical tool for characterizing disease and predicting clinical outcomes from radiological images such as CT. Photon-counting-detector (PCD) CT provides improved spatial resolution and dose efficiency relative to conventional energy-integrating-detector CT systems. Since improved spatial resolution enables visualization of smaller structures and more details that are not typically visible at routine resolution, it has a direct impact on textural features in CT images. Therefore, it is of clinical interest to quantify the impact of the improved spatial resolution on calculated radiomic features and, consequently, on sample classification. In this work, organic samples (zucchini, onions, and oranges) were scanned on both clinical PCD-CT and EID- CT systems at two dose levels. High-resolution PCD-CT and routine-resolution EID-CT images were reconstructed using a dedicated sharp kernel and a routine kernel, respectively. The noise in each image was quantified. Fourteen radiomic features of relevance were calculated in each image for each sample and compared between the two scanners. Radiomic features were plotted pairwise to evaluate the resulting cluster separation of the samples by their type between PCD-CT and EID-CT. Thirteen out of 14 studied radiomic features were notably changed by the improved resolution of the PCD-CT system, and the cluster separation was better when assessing features derived from PCD-CT. These results show that features derived from high-resolution PCD-CT, which are subject to higher noise compared to EID-CT, may impact radiomics-based clinical decision making.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Improved visualization of the wrist at lower radiation dose with photon-counting-detector CT
    Rajendran, Kishore
    Baffour, Francis
    Powell, Garret
    Glazebrook, Katrina
    Thorne, Jamison
    Larson, Nicholas
    Leng, Shuai
    McCollough, Cynthia
    Fletcher, Joel
    SKELETAL RADIOLOGY, 2023, 52 (01) : 23 - 29
  • [2] Improved visualization of the wrist at lower radiation dose with photon-counting-detector CT
    Kishore Rajendran
    Francis Baffour
    Garret Powell
    Katrina Glazebrook
    Jamison Thorne
    Nicholas Larson
    Shuai Leng
    Cynthia McCollough
    Joel Fletcher
    Skeletal Radiology, 2023, 52 : 23 - 29
  • [3] Estimating the Clinical Impact of Photon-Counting-Detector CT in Diagnosing Usual Interstitial Pneumonia
    Inoue, Akitoshi
    Johnson, Tucker F.
    White, Darin
    Cox, Christian W.
    Hartman, Thomas E.
    Thorne, Jamison E.
    Shanblatt, Elisabeth R.
    Johnson, Matthew P.
    Carter, Rickey E.
    Lee, Yong S.
    Rajendran, Kishore
    Leng, Shuai
    McCollough, Cynthia H.
    Fletcher, Joel G.
    INVESTIGATIVE RADIOLOGY, 2022, 57 (11) : 734 - 741
  • [4] Improved coronary calcification quantification using photon-counting-detector CT: an ex vivo study in cadaveric specimens
    Mårten Sandstedt
    Jeffrey Marsh
    Kishore Rajendran
    Hao Gong
    Shengzhen Tao
    Anders Persson
    Shuai Leng
    Cynthia McCollough
    European Radiology, 2021, 31 : 6621 - 6630
  • [5] Improved coronary calcification quantification using photon-counting-detector CT: an ex vivo study in cadaveric specimens
    Sandstedt, Marten
    Marsh, Jeffrey, Jr.
    Rajendran, Kishore
    Gong, Hao
    Tao, Shengzhen
    Persson, Anders
    Leng, Shuai
    McCollough, Cynthia
    EUROPEAN RADIOLOGY, 2021, 31 (09) : 6621 - 6630
  • [6] Development and validation of a noise insertion algorithm for photon-counting-detector CT
    Winfree, Timothy
    McCollough, Cynthia
    Yu, Lifeng
    MEDICAL PHYSICS, 2024, 51 (09) : 5943 - 5953
  • [7] Ultra-high-resolution imaging of the shoulder and pelvis using photon-counting-detector CT: a feasibility study in patients
    Baffour, Francis, I
    Rajendran, Kishore
    Glazebrook, Katrina N.
    Thorne, Jamison E.
    Larson, Nicholas B.
    Leng, Shuai
    McCollough, Cynthia H.
    Fletcher, Joel G.
    EUROPEAN RADIOLOGY, 2022, 32 (10) : 7079 - 7086
  • [8] Joint Reconstruction and Spectrum Refinement for Photon-Counting-Detector Spectral CT
    Shen, Le
    Xing, Yuxiang
    Zhang, Li
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2023, 42 (09) : 2653 - 2665
  • [9] Technical note: Exploring the detectability of coronary calcification using ultra-high-resolution photon-counting-detector CT
    Chang, Shaojie
    Ren, Liqiang
    Tang, Shanshan
    Marsh Jr, Jeffrey F.
    Hsieh, Scott
    Mccollough, Cynthia H.
    Leng, Shuai
    MEDICAL PHYSICS, 2023, 50 (11) : 6836 - 6843
  • [10] Material Decomposition in Photon-Counting-Detector CT: Threshold or Bin Images?
    Ren, Liqiang
    Tao, Shengzhen
    McCollough, Cynthia H.
    Yu, Lifeng
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948