Evaluation of noninvasive hemoglobin monitoring in children with congenital heart diseases

被引:4
作者
Kamel, Mohamed Maher [1 ]
Hasanin, Ahmed [1 ]
Nawar, Beshoy [1 ]
Mostafa, Maha [1 ]
Jacob, Victor F. [1 ]
Elhadi, Hany [1 ]
Alsadek, Wafaa [1 ]
Elmetwally, Sarah A. [1 ]
机构
[1] Cairo Univ, Dept Anesthesia & Crit Care Med, Cairo, Egypt
关键词
children; congenital heart disease; cyanotic heart disease; Noninvasive hemoglobin monitoring; ACCURACY; OXIMETRY;
D O I
10.1111/pan.13851
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background Noninvasive measurement of blood hemoglobin could save time and decrease the risk of anemia and infection. The accuracy of CO-oximetry-derived noninvasive hemoglobin (Sp-Hb) had been evaluated in pediatric population; however, its accuracy in children with congenital heart disease has not been studied till date. We evaluated the accuracy of Sp-Hb in relation to laboratory-measured hemoglobin (Lab-Hb) in children with congenital heart disease. Methods This prospective observational study included children with congenital heart disease undergoing procedural intervention. Sp-Hb measurements were obtained using Radical-7 Masimo pulse CO-oximeter and were compared against simultaneous Lab-Hb measurements obtained from the arterial line. Children were divided in cyanotic and acyanotic, and separate analysis was performed for each group. The values of both measurements were analyzed using Spearman's correlation coefficient and Bland-Altman analysis. Correlation was performed between Sp-Hb and Lab-Hb bias and each of arterial oxygen saturation and perfusion index. Results One-hundred and eleven pairs of readings were obtained from 65 children. The median (quartiles) age and weight of the children were 1 (1.2-4) years and 11 (8-17) kg, respectively. There was moderate correlation between Lab-Hb and Sp-Hb with a correlation coefficient (95% confidence interval [CI]) of 0.75 (0.63-0.83) in acyanotic children and 0.62 (0.37-0.79) in cyanotic children. The mean bias (95% limits of agreements) was -0.4 g/dL (-2.4 to 1.6 g/dL) and 1 g/dL (-2.7 to 4.6 g/dL) in acyanotic and cyanotic children, respectively. The mean bias between Sp-Hb and Lab-Hb showed a weak negative correlation with oxygen saturation (r [95% CI]): (-0.36 [-0.51--0.18]), and a weak positive correlation with the perfusion index (r [95% CI]): (0.19 [0.01-0.37]). Conclusion The large bias and the wide limits of agreement between Sp-Hb and Lab-Hb denote that Masimo-derived Sp-Hb is not accurate in children with congenital heart disease especially in the cyanotic group; the error in Sp-Hb increases when oxygen saturation decreases.
引用
收藏
页码:571 / 576
页数:6
相关论文
共 17 条
[1]   Accuracy and trending of non-invasive hemoglobin measurement during different volume and perfusion statuses [J].
Adel, Abdelmoneim ;
Awada, Wael ;
Abdelhamid, Bassant ;
Omar, Heba ;
Abd El Dayem, Omnia ;
Hasanin, Ahmed ;
Rady, Ashraf .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (06) :1025-1031
[2]   Recommendations on RBC Transfusion in Infants and Children With Acquired and Congenital Heart Disease From the Pediatric Critical Care Transfusion and Anemia Expertise Initiative [J].
Cholette, Jill M. ;
Willems, Ariane ;
Valentine, Stacey L. ;
Bateman, Scot T. ;
Schwartz, Steven M. .
PEDIATRIC CRITICAL CARE MEDICINE, 2018, 19 :S137-S148
[3]   Accuracy of Carboxyhemoglobin Detection by Pulse CO-Oximetry During Hypoxemia [J].
Feiner, John R. ;
Rollins, Mark D. ;
Sall, Jeffrey W. ;
Eilers, Helge ;
Au, Paul ;
Bickler, Philip E. .
ANESTHESIA AND ANALGESIA, 2013, 117 (04) :847-858
[4]   EVALUATION OF NONINVASIVE HEMOGLOBIN MONITORING IN TRAUMA PATIENTS WITH LOW HEMOGLOBIN LEVELS [J].
Gamal, Medhat ;
Abdelhamid, Bassant ;
Zakaria, Dina ;
Abd El Dayem, Omnia ;
Rady, Ashraf ;
Fawzy, Maher ;
Hasanin, Ahmed .
SHOCK, 2018, 49 (02) :150-153
[5]   Accuracy of the Masimo SET® LNCS neo peripheral pulse oximeter in cyanotic congenital heart disease [J].
Griksaitis, Michael J. ;
Scrimgeour, Gemma E. ;
Pappachan, John V. ;
Baldock, Andrew J. .
CARDIOLOGY IN THE YOUNG, 2016, 26 (06) :1183-1186
[6]   Accuracy of a portable pulse oximeter in monitoring hypoxemic infants with cyanotic heart disease [J].
Harris, Bronwyn U. ;
Stewart, Sarah ;
Verma, Archana ;
Hoen, Helena ;
Stein, Mary Lyn ;
Wright, Gail ;
Ramamoorthy, Chandra .
CARDIOLOGY IN THE YOUNG, 2019, 29 (08) :1025-1029
[7]   Accuracy of Pulse Oximeters Intended for Hypoxemic Pediatric Patients [J].
Harris, Bronwyn U. ;
Char, Danton S. ;
Feinstein, Jeffrey A. ;
Verma, Archana ;
Shiboski, Stephen C. ;
Ramamoorthy, Chandra .
PEDIATRIC CRITICAL CARE MEDICINE, 2016, 17 (04) :315-320
[8]   Accuracy of Continuous Noninvasive Hemoglobin Monitoring: A Systematic Review and Meta-Analysis [J].
Kim, Sang-Hyun ;
Lilot, Marc ;
Murphy, Linda Suk-Ling ;
Sidhu, Kulraj S. ;
Yu, Zhaoxia ;
Rinehart, Joseph ;
Cannesson, Maxime .
ANESTHESIA AND ANALGESIA, 2014, 119 (02) :332-346
[9]   The Accuracy of Noninvasive Hemoglobin Monitoring Using the Radical-7 Pulse CO-Oximeter in Children Undergoing Neurosurgery [J].
Park, Yong-Hee ;
Lee, Ji-Hyun ;
Song, Hyun-Gul ;
Byon, Hyo-Jin ;
Kim, Hee-Soo ;
Kim, Jin-Tae .
ANESTHESIA AND ANALGESIA, 2012, 115 (06) :1302-1307
[10]   Trending and Accuracy of Noninvasive Hemoglobin Monitoring in Pediatric Perioperative Patients [J].
Patino, Mario ;
Schultz, Lindsay ;
Hossain, Monir ;
Moeller, Jennifer ;
Mahmoud, Mohamed ;
Gunter, Joel ;
Kurth, C. Dean .
ANESTHESIA AND ANALGESIA, 2014, 119 (04) :920-925