Investigation of heavy metal accumulation in mung bean (Vigna radiate) through inductively coupled plasma optical emission spectroscopy

被引:1
|
作者
Feleke, Tadesse [1 ]
Tesfaye, Azene [2 ]
机构
[1] Debre Birhan Univ, Coll Nat & Computat Sci, Dept Chem, Debre Birhan, Ethiopia
[2] Arba Minch Univ, Coll Med & Hlth Sci, Dept Med Lab Sci, Arba Minch, Ethiopia
来源
EURASIAN CHEMICAL COMMUNICATIONS | 2021年 / 3卷 / 08期
关键词
Environmental pollution; heavy metal; irrigation; ICP-OES; Vigna radiata; PRECONCENTRATION; OPTIMIZATION; VEGETABLES; ELEMENTS; SAMPLES; COPPER; AREA; CITY; SOIL;
D O I
10.22034/ecc.2021.278034.1153
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Although mung bean is cultivated for its nutritional crop in a different region of Ethiopia through irrigation, its production is hindered by excess accumulation of heavy metals in the environment. The presence of excess heavy metals in the environment subsequently leads to the contamination of consumable products, hampered crop productivity, and subsequently affects human health. The present study aimed to determine the concentrations of selected heavy metals (Pb, Cu, and Cr) in the mung bean collected from Shewarobit, Northcentral, Ethiopia, using inductively coupled plasma optical emission spectroscopy (ICP-OES). Dried seeds of mungbean were digested in a microwave oven by nitric acid and hydrogen peroxide for 1 hr at a temperature of 90 degrees C to 95 degrees C by a hot plate digester and then the concentration of Pb, Cu, and Cr was measured through inductively coupled plasma optical emission spectrophotometry (ICP-OES). The result revealed that the concentration of heavy metals in the samples was 2.51 mg/L, 6.53 mg/L, and 0.38 mg/L for Pb, Cu, and Cr, respectively. Copper (Cu) was found to be higher, followed by lead (Pb) and chromium (Cr). The overall accuracy and applicability of the method were confirmed through spiking experiments (recovery) in the range of 80 to 120%, which account for 110.5% +/- 0.039, 96.0% +/- 0.236, 102.0% +/- 0.085 for Pb, Cr, and Cu, respectively. The concentration of Cu and Cr in mung bean falls under the permissible limit. However, the amount of lead is higher than the permissible limit and it is unsafe to consume. Thus, appropriate measures should be done to adjust its concentration.
引用
收藏
页码:542 / 550
页数:9
相关论文
共 50 条
  • [11] Ion balance in waters through inductively coupled plasma optical emission spectrometry
    Sanchez, Carlos
    Enrique Maestre, Salvador
    Soledad Prats, Maria
    Luis Todoli, Jose
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2014, 94 (05) : 427 - 440
  • [12] Manganese quantification in some Egyptian food items using inductively coupled plasma optical emission spectroscopy
    Elghnam, Sameh M.
    Aborhyem, Samar M.
    Khedr, Yasser, I
    CYTA-JOURNAL OF FOOD, 2022, 20 (01) : 199 - 205
  • [13] Chromium speciation analysis by ion chromatography coupled with inductively coupled plasma-optical emission spectroscopy
    Coetzee, PP
    Fischer, JL
    van Vuuren, SJ
    SOUTH AFRICAN JOURNAL OF CHEMISTRY-SUID-AFRIKAANSE TYDSKRIF VIR CHEMIE, 2004, 57 : 8 - 14
  • [14] Measurement and analysis of mineral and heavy metal components in grape cultivars by inductively coupled plasma-optical emission spectrometer (ICP-OES)
    Feng-Mei Zhu
    Bin Du
    Feng-Ying Li
    Jian-Cai Zhang
    Jun Li
    Journal für Verbraucherschutz und Lebensmittelsicherheit, 2012, 7 : 137 - 140
  • [15] Characterization of Pottery from Teotihuacan Using Laser-Induced Breakdown Spectroscopy and Inductively Coupled Plasma Optical Emission Spectroscopy
    Sobral, Hugo
    Amador-Mejia, Mitzi
    Marquez-Herrera, Ciro
    APPLIED SPECTROSCOPY, 2021, 75 (06) : 728 - 738
  • [16] Determination of Some Trace Elements in Dried Red Plum Using Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES)
    Sukru, Kalayci
    Sinan, Muhammet
    IRANIAN JOURNAL OF CHEMISTRY & CHEMICAL ENGINEERING-INTERNATIONAL ENGLISH EDITION, 2022, 41 (11): : 3742 - 3746
  • [17] Measurement of titanium in hip-replacement patients by inductively coupled plasma optical emission spectroscopy
    Harrington, Chris F.
    McKibbin, Craig
    Rahanu, Monika
    Langton, David
    Taylor, Andrew
    ANNALS OF CLINICAL BIOCHEMISTRY, 2017, 54 (03) : 362 - 369
  • [18] Inductively Coupled Plasma Optical Emission Spectroscopy Determination of Trace Element Composition of Argan Oil
    Gonzalvez, A.
    Ghanjaoui, M. E.
    El Rhazi, M.
    de la Guardia, M.
    FOOD SCIENCE AND TECHNOLOGY INTERNATIONAL, 2010, 16 (01) : 65 - 71
  • [19] Determination of trace metal levels in the sea and fresh water in Oman by using inductively coupled plasma-optical emission spectroscopy
    Ayman Alsaid Ibrahim Alsaid
    Aya Mohammed Amin Ahmed
    Rayyan Hamed Al Qamshouai
    Mohammad Sohail Akhtar
    Salem Said Jaroof Al-Touby
    Mohammad Amzad Hossain
    Arabian Journal of Geosciences, 2023, 16 (2)
  • [20] DETERMINATION OF HEAVY METALS IN BEE HONEY USING BY INDUCTIVELY COUPLED PLASMA OPTICAL EMISSION SPECTROMETRY (ICP-OES)
    Demirezen, Dilek
    Aksoy, Ahmet
    GAZI UNIVERSITY JOURNAL OF SCIENCE, 2005, 18 (04): : 569 - 575