Assessment of the sensitivity of core/shell parameters derived using the single-particle soot photometer to density and refractive index

被引:86
|
作者
Taylor, J. W. [1 ]
Allan, J. D. [1 ,2 ]
Liu, D. [1 ]
Flynn, M. [1 ]
Weber, R. [3 ]
Zhang, X. [3 ]
Lefer, B. L. [4 ]
Grossberg, N. [4 ]
Flynn, J. [4 ]
Coe, H. [1 ]
机构
[1] Univ Manchester, Ctr Atmospher Sci, Sch Earth Atmospher & Environm Sci, Manchester, Lancs, England
[2] Univ Manchester, Natl Ctr Atmospher Sci, Manchester, Lancs, England
[3] Georgia Inst Technol, Atlanta, GA 30332 USA
[4] Univ Houston, Dept Earth & Atmospher Sci, Houston, TX USA
基金
英国自然环境研究理事会;
关键词
RADIATIVE ABSORPTION ENHANCEMENTS; BLACK CARBON MEASUREMENTS; MIXING STATE; OPTICAL-PROPERTIES; LIGHT-SCATTERING; AEROSOL; AMPLIFICATION; VALIDATION; VOLATILITY;
D O I
10.5194/amt-8-1701-2015
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Black carbon (BC) is the dominant absorbing aerosol in the atmosphere, and plays an important role in climate and human health. The optical properties and cloud condensation nuclei (CCN) activity of soot depend on the amounts (both relative and absolute) of BC and non-refractory material in the particles. Mixing between these two components is often represented in models by a core / shell coated sphere. The single-particle soot photometer (SP2) is one of, if not the only, instrument capable of reporting distributions of both core size and coating thickness. Most studies combine the SP2's incandescence and 1064 nm scattering data to report coating properties, but to date there is no consistency in the assumed values of density and refractive index of the core that are used in these calculations, which can greatly affect the reported parameters such as coating thickness. Given that such data are providing an important constraint for model comparisons and comparison between large data sets, it is important that this lack of consistency is addressed. In this study we explore the sensitivity of the reported coatings to these parameters. An assessment of the coating properties of freshly emitted, thermodenuded ambient particles demonstrated that a core density of 1.8 g cm(3) and refractive index of (2.26-1.26i) were the most appropriate to use with ambient soot in the Los Angeles area. Using these parameters generated a distribution with median shell / core ratio of 1.02 +/- 0.11, corresponding to a median absolute coating thickness of 2 +/- 8 nm. The main source of statistical error in the single-particle data was random variation in the incandescence signals. Other than the sensitivity to core refractive index, the incandescence calibration was the main source of uncertainty when optically determining the average coatings. The refractive index of coatings was found to have only a minor influence. This work demonstrates that using this technique the SP2 can accurately determine the average mixing state (externally or internally mixed) of ambient soot within the precision of the instrument calibration. Ambient coatings were measured up to a median shell / core ratio of 1.50 +/- 0.11, meaning that this technique is able to resolve absolute changes in mixing state. However, when different core parameters were used, the core = shell ratio and the coating thickness were shown to be offset by amounts that could be larger than the atmospheric variability in these parameters, though the results have a similar precision. For comparison, using the core parameters that resulted in the thickest coatings, on the same thermodenuded fresh particles as before, generated a median shell = core ratio of 1.39 +/- 0.11, corresponding to a median absolute coating thickness of 30 +/- 8 nm. These results must be taken into account when comparing BC coatings measured using this technique, or if using these data for optical or CCN calculations. We have determined the most appropriate values of BC density and refractive index to use to measure mixing state at 1064 nm where particle morphology has only a minor effect, but appropriate values to use for optical calculations of non-spherical particles at visible wavelengths will also be subject to similar, significant uncertainties. Without similar constraints as those provided here, constraining the behaviour of BC particles in models using field data will be subject to large systematic measurement uncertainties.
引用
收藏
页码:1701 / 1718
页数:18
相关论文
共 21 条
  • [1] Method to measure the size-resolved real part of aerosol refractive index using differential mobility analyzer in tandem with single-particle soot photometer
    Zhao, Gang
    Zhao, Weilun
    Zhao, Chunsheng
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2019, 12 (07) : 3541 - 3550
  • [2] Determination of and evidence for non-core-shell structure of particles containing black carbon using the Single-Particle Soot Photometer (SP2)
    Sedlacek, Arthur J., III
    Lewis, Ernie R.
    Kleinman, Lawrence
    Xu, Jianzhong
    Zhang, Qi
    GEOPHYSICAL RESEARCH LETTERS, 2012, 39
  • [3] A novel method for estimating light-scattering properties of soot aerosols using a modified single-particle soot photometer
    Gao, R. S.
    Schwarz, J. P.
    Kelly, K. K.
    Fahey, D. W.
    Watts, L. A.
    Thompson, T. L.
    Spackman, J. R.
    Slowik, J. G.
    Cross, E. S.
    Han, J. -H.
    Davidovits, P.
    Onasch, T. B.
    Worsnop, D. R.
    AEROSOL SCIENCE AND TECHNOLOGY, 2007, 41 (02) : 125 - 135
  • [4] Detection of light-absorbing iron oxide particles using a modified single-particle soot photometer
    Yoshida, Atsushi
    Moteki, Nobuhiro
    Ohata, Sho
    Mori, Tatsuhiro
    Tada, Ryuji
    Dagsson-Waldhauserova, Pavla
    Kondo, Yutaka
    AEROSOL SCIENCE AND TECHNOLOGY, 2016, 50 (03) : i - iv
  • [5] Investigation of Refractory Black Carbon-Containing Particle Morphologies Using the Single-Particle Soot Photometer (SP2)
    Sedlacek, Arthur J., III
    Lewis, Ernie R.
    Onasch, Timothy B.
    Lambe, Andrew T.
    Davidovits, Paul
    AEROSOL SCIENCE AND TECHNOLOGY, 2015, 49 (10) : 872 - 885
  • [6] Single-particle detection using high-refractive index film coated in microring resonator
    Zhang, Zhi-Hong
    Li, Mu-Neng
    Gui, Feng-Ji
    Shang, Si-Hui
    HOLOGRAPHY, DIFFRACTIVE OPTICS, AND APPLICATIONS VIII, 2018, 10818
  • [7] Mixing states of light-absorbing particles measured using a transmission electron microscope and a single-particle soot photometer in Tokyo, Japan
    Adachi, Kouji
    Moteki, Nobuhiro
    Kondo, Yutaka
    Igarashi, Yasuhito
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2016, 121 (15) : 9153 - 9164
  • [8] Secondary Organic Aerosol Coating Formation and Evaporation: Chamber Studies Using Black Carbon Seed Aerosol and the Single-Particle Soot Photometer
    Metcalf, Andrew R.
    Loza, Christine L.
    Coggon, Matthew M.
    Craven, Jill S.
    Jonsson, Haflidi H.
    Flagan, Richard C.
    Seinfeld, John H.
    AEROSOL SCIENCE AND TECHNOLOGY, 2013, 47 (03) : 326 - 347
  • [9] Evaluation of black carbon mass concentrations using a miniaturized aethalometer: Intercomparison with a continuous soot monitoring system (COSMOS) and a single-particle soot photometer (SP2)
    Miyakawa, Takuma
    Mordovskoi, Petr
    Kanaya, Yugo
    AEROSOL SCIENCE AND TECHNOLOGY, 2020, 54 (07) : 811 - 825
  • [10] A study of the morphology and effective density of externally mixed black carbon aerosols in ambient air using a size-resolved single-particle soot photometer (SP2)
    Wu, Yunfei
    Xia, Yunjie
    Huang, Rujin
    Deng, Zhaoze
    Tian, Ping
    Xia, Xiangao
    Zhang, Renjian
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2019, 12 (08) : 4347 - 4359