Investigation on the Effect of Platform Height on Smoke Characteristics of Fire Scenarios for Subway Stations

被引:4
|
作者
Xu, Desheng [1 ]
Li, Yanfeng [2 ]
Li, Junmei [1 ]
Zhang, Jin [3 ]
Li, Jiaxin [1 ]
机构
[1] Beijing Univ Technol, Beijing Key Lab Green Built Environm & Energy Eff, Beijing 100124, Peoples R China
[2] Beijing Univ Technol, Coll Architecture & Civil Engn, Beijing 100124, Peoples R China
[3] Beijing Municipal Inst Lab Protect, Beijing Key Lab Control Technol City Tox & Combus, Beijing 100054, Peoples R China
基金
北京市自然科学基金;
关键词
full-scale; fire experiment; simulation; smoke control; CARBON-MONOXIDE TRANSPORTATION; AIR-CURTAIN; TRAIN FIRE; TEMPERATURE; VENTILATION; ATRIUM; SYSTEM; SIMULATION; STRATEGY;
D O I
10.3390/su131910584
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, three full-scale experiments and a series of numerical simulations were conducted to investigate the influence of subway platform height and atrium ceiling height of subway stations on smoke control by mechanical exhausting systems. The smoke temperature variation with time, maximum temperature distribution, and smoke stratification were discussed. Results showed that the atrium had capacity to store smoke, especially at the early stage of smoke spread. However, the efficiency of smoke extraction did not increase simply with the rise in platform height and atrium ceiling height, and favorable smoke exhaust velocity was crucial for smoke elimination. The optimal smoke exhaust velocity was studied by numerical simulation and it was found that the area of smoke diffusion in subway stations with a higher platform was significantly smaller under the optimal smoke exhaust velocity. In addition, a prediction model of optimal smoke exhaust velocity with subway platform height was proposed. This study could provide on-site data and smoke spread characteristics for smoke control design, operation, and, significantly, guide safety evacuation of the exhaust system of subway stations.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Numerical simulation of fire smoke control methods in subway stations and collaborative control system for emergency rescue
    Wang, Kai
    Cai, Weiyao
    Zhang, Yuchen
    Hao, Haiqing
    Wang, Ziting
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2021, 147 : 146 - 161
  • [22] Experimental investigation on the characteristics and propagation of fire inside subway train
    Peng, Min
    Cheng, Xudong
    Cong, Wei
    Yang, Hui
    Shi, Long
    Yuen, Richard
    Zhang, Heping
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2021, 107 (107)
  • [23] Numerical investigation of smoke exhaust mechanism in a gymnasium under fire scenarios
    Qin, T. X.
    Guo, Y. C.
    Chan, C. K.
    Lin, W. Y.
    BUILDING AND ENVIRONMENT, 2006, 41 (09) : 1203 - 1213
  • [24] Prediction of the spread of smoke in a huge transit terminal subway station under six different fire scenarios
    Gao, Ran
    Li, Angui
    Hao, Xinpeng
    Lei, Wenjun
    Deng, Baoshun
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2012, 31 : 128 - 138
  • [25] Comparative Research on FLUENT and FDS's Numerical Simulation of Smoke Spread in Subway Platform Fire
    Wang Binbin
    ISMSSE 2011, 2011, 26
  • [26] Impact of the Heat Release Rate to the Flow Characteristics of Fire Smoke in Subway Tunnel Under the Effect of Piston Wind
    Na, Zhang
    Dan, Zhou
    2016 IEEE INTERNATIONAL CONFERENCE ON INTELLIGENT RAIL TRANSPORTATION (ICIRT), 2016, : 394 - 400
  • [27] A study of the fire smoke propagation in subway station under the effect of piston wind
    Zhong, Wei
    Tu, Rui
    Yang, Jian Peng
    Liang, Tian Shui
    JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2015, 21 (04) : 514 - 523
  • [28] Influence of tunnel slope on movement characteristics of thermal smoke in a moving subway train fire
    Zhou, Dan
    Hu, Tianen
    Wang, Zhe
    Chen, Tao
    Li, Xiaofang
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 28
  • [29] Effect Analysis of Different Exhaust Velocity on Fire Smoke Control in Subway Tunnel
    Han, Xin
    Gao, Xiaoming
    Cong, Beihua
    ADVANCED RESEARCH ON ENGINEERING MATERIALS, ENERGY, MANAGEMENT AND CONTROL, PTS 1 AND 2, 2012, 424-425 : 1224 - +
  • [30] Influence of door numbers and platform height on interval tunnel evacuation under a moving subway train with fire
    Sun J.
    Lu Z.
    Zhou D.
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2024, 55 (04): : 1581 - 1590