Quantitative 3-Dimensional Computed Tomography Measurement of Volar Shearing Fractures of the Distal Radius

被引:12
|
作者
Souer, J. Sebastian [1 ]
Wiggers, Jimme [1 ]
Ring, David [1 ]
机构
[1] Harvard Univ, Yawkey Ctr, Massachusetts Gen Hosp, Orthopaed Hand & Upper Extrem Serv,Med Sch, Boston, MA 02114 USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2011年 / 36A卷 / 04期
关键词
Computed tomography; fractures; morphology; quantitative; distal radius; FIXATION; PART;
D O I
10.1016/j.jhsa.2010.12.026
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose We used a method for quantitative measurement of articular surface area based on 3-dimensional computed tomography (CT) images to test the hypothesis that among volar shearing fractures of the distal radius, complete articular fractures have on average larger volar fracture fragments than partial articular fractures. Methods We analyzed 25 adult patients with a quantitative 3-dimensional CT scan of a volar shearing fracture of the distal radius. We identified 3 major fracture patterns: 10 fractures were complete articular fractures (AO C-type; complete dorsal fracture line); 8 fractures had an intact dorsal lunate facet (radial dorsal fracture line; labeled transitional type B fractures); and 7 fractures had no dorsal fracture (true AO type B partial articular fractures). Results All of the type C and transitional type B fractures, but only one of the true type B fractures had a split (fragmentation) in the dorsal articular surface (p < .001). Four of 10 type C, 6 of 8 partial type B and 2 of 7 type B fractures had fragmentation of the volar articular surface (p = .19). The articular surface area of the volar fragments in type B fractures tended to be larger (average 56%; range, 38% to 78% of the total articular surface area) compared with partial type B (average 42; range, 28% to 51%) and type C (47%; range, 25% to 68%) fractures although the differences were not statistically significant with the numbers available. Conclusions We identified 3 major volar shearing fracture patterns (complete, transitional partial, and partial articular). Although the differences in the average volar fractures surface area were not statistically significant with the numbers available, complete fractures and transitional partial fractures (intact dorsal lunate facet) were significantly more likely to have dorsal comminution. (J Hand Surg 2011;36A:599-603. Copyright (c) 2011 by the American Society for Surgery of the Hand. All rights reserved.)
引用
收藏
页码:599 / 603
页数:5
相关论文
共 50 条
  • [1] Quantitative 3-dimensional computed tomography measurement of distal humerus fractures
    Brouwer, Kim M.
    Bolmers, Annelies
    Ring, David
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (07) : 977 - 982
  • [2] Quantitative 3-dimensional computed tomography analysis of olecranon fractures
    Lubberts, Bart
    Janssen, Stein
    Mellema, Jos
    Ring, David
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (05) : 831 - 836
  • [3] Quantitative 3-Dimensional Computed Tomography Measurements of Coronoid Fractures
    Mellema, Jos J.
    Janssen, Stein J.
    Guitton, Thierry G.
    Ring, David
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (03): : 526 - 533
  • [4] Computed Tomography and Pathobiomechanical-Based Treatment of Volar Distal Radius Fractures
    Hintringer, Wolfgang
    Rosenauer, Rudolf
    Quadlbauer, Stefan
    JOURNAL OF WRIST SURGERY, 2022, 11 (03) : 203 - 213
  • [5] The Detection of Prominent Hardware in Volar Locked Plating of Distal Radius Fractures: Intraoperative Fluoroscopy Versus Computed Tomography
    Ganesh, Devin
    Service, Ben
    Zirgibel, Brian
    Koval, Kenneth
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (11) : 618 - 621
  • [6] Biomechanical Properties of 3-Dimensional Printed Volar Locking Distal Radius Plate: Comparison With Conventional Volar Locking Plate
    Kim, Sung-Jae
    Jo, Young-Hoon
    Choi, Wan-Sun
    Lee, Chang-Hun
    Lee, Bong-Gun
    Kim, Joo-Hak
    Lee, Kwang-Hyun
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2017, 42 (09): : 747.e1 - 747.e6
  • [7] Dorsal Cortical Breaks in Volar Barton Distal Radius Fractures
    Daly, Michael C.
    Horst, Taylor A.
    Mudgal, Chaitanya S.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2021, 16 (03): : 303 - 309
  • [8] Computed Tomography Evaluation of Distal Screw Penetration in Volar Locking Plate Fixation for Intra-Articular Distal Radius Fractures
    Kaneshiro, Yasunori
    Hyun, Seungho
    Yano, Koichi
    Yokoi, Takuya
    Sakanaka, Hideki
    Hidaka, Noriaki
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2023, 48 (06): : 553 - 558
  • [9] Distal radius fractures - A volar plate is not just a volar plate
    Knight, Richard
    Elliott, Lucy
    Brewster, Mark
    Spiteri, Michelle
    Power, Dominic
    TRAUMA-ENGLAND, 2018, 20 (03): : 203 - 207
  • [10] Quantitative three-dimensional computed tomography measurement of radial head fractures
    Guitton, Thierry G.
    van der Werf, Huub J.
    Ring, David
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (07) : 973 - 977