Label-free sensing of the binding state of MUC1 peptide and anti-MUC1 aptamer solution in fluidic chip by terahertz spectroscopy

被引:26
|
作者
Zhao, Xiang [1 ]
Zhang, Mingkun [2 ]
Wei, Dongshan [2 ]
Wang, Yunxia [1 ]
Yan, Shihan [2 ]
Liu, Mengwan [2 ]
Yang, Xiang [1 ]
Yang, Ke [1 ]
Cui, Hong-Liang [2 ]
Fu, Weiling [1 ]
机构
[1] Third Mil Med Univ, Southwest Hosp, Dept Lab Med, Chongqing 400038, Peoples R China
[2] Chinese Acad Sci, Chongqing Inst Green & Intelligent Technol, Chongqing Key Lab Multiscale Mfg Technol, Chongqing 400714, Peoples R China
来源
BIOMEDICAL OPTICS EXPRESS | 2017年 / 8卷 / 10期
基金
中国国家自然科学基金;
关键词
MOLECULAR-DYNAMICS SIMULATION; HIGHLY SENSITIVE DETECTION; TUMOR-MARKER; NEUTRON-SCATTERING; BREAST-CANCER; LIQUID WATER; PROTEIN; BIOSENSOR; HYDRATION; COMPLEX;
D O I
10.1364/BOE.8.004427
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The aptamer and target molecule binding reaction has been widely applied for construction of aptasensors, most of which are labeled methods. In contrast, terahertz technology proves to be a label-free sensing tool for biomedical applications. We utilize terahertz absorption spectroscopy and molecular dynamics simulation to investigate the variation of binding-induced collective vibration of hydrogen bond network in a mixed solution of MUC1 peptide and anti-MUC1 aptamer. The results show that binding-induced alterations of hydrogen bond numbers could be sensitively reflected by the variation of terahertz absorption coefficients of the mixed solution in a customized fluidic chip. The minimal detectable concentration is determined as 1 pmol/mu L, which is approximately equal to the optimal immobilized concentration of aptasensors. (C) 2017 Optical Society of America
引用
收藏
页码:4427 / 4437
页数:11
相关论文
共 6 条
  • [1] Molecular Dynamics Simulation Analysis of Anti-MUC1 Aptamer and Mucin 1 Peptide Binding
    Rhinehardt, Kristen L.
    Srinivas, Goundla
    Mohan, Ram V.
    JOURNAL OF PHYSICAL CHEMISTRY B, 2015, 119 (22) : 6571 - 6583
  • [2] Binding of circulating anti-MUC1 antibody and serum MUC1 antigen in stage IV breast cancer
    Tang, Yan
    Cui, Xiuxia
    Xiao, Han
    Qi, Shengkun
    Hu, Xiaoping
    Yu, Qiong
    Shi, Guang
    Zhang, Xue
    Gu, Jiaying
    Yu, Yongli
    Wang, Liying
    Li, Yarong
    MOLECULAR MEDICINE REPORTS, 2017, 15 (05) : 2659 - 2664
  • [3] Solution structure of a truncated anti-MUC1 DNA aptamer determined by mesoscale modeling and NMR
    Baouendi, Meriem
    Cognet, Jean A. H.
    Ferreira, Catia S. M.
    Missailidis, Sotiris
    Coutant, Jerome
    Piotto, Martial
    Hantz, Edith
    du Penhoat, Catherine Herve
    FEBS JOURNAL, 2012, 279 (03) : 479 - 490
  • [4] Label-free sensitive detection of MUC1 using a liquid crystal based-system
    Duong, Thai Duong Song
    Jang, Chang-Hyun
    LIQUID CRYSTALS, 2020, 47 (12) : 1784 - 1793
  • [5] Development of Pt/Au/PPy-COOH multisegmental nanowires modified label-free impedimetric immunosensor to determine mucin 1 (MUC1)
    Ondes, Baha
    Uygun, Deniz Aktas
    ANALYTICAL BIOCHEMISTRY, 2025, 702
  • [6] Label-free and dual-amplified electrochemical bioanalysis of MUC1 based on an inorganic-organic polymer hybrid mimic peroxidase (AuNPs@Cu7S4@Cu/Mn-AzoPPOP) and catalytic hairpin assembly
    Zhao, Huijuan
    Liu, Tingting
    Cui, Lin
    Li, Yanhong
    Yang, Fei
    Zhang, Xiaomei
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 345