Assessment of three-dimensional ultrasound examination classification to check the position of the tubal sterilization microinsert

被引:38
作者
Legendre, Guillaume [1 ,2 ,3 ]
Gervaise, Amelie [2 ]
Levaillant, Jean-Marc [2 ]
Faivre, Erika [2 ]
Deffieux, Xavier [2 ,4 ,5 ]
Fernandez, Herve [1 ,3 ,4 ,5 ]
机构
[1] Hop Bicetre, Serv Gynecol Obstet, AP HP, F-94275 Le Kremlin Bicetre, France
[2] Hop Antoine Beclere, Serv Gynecol Obstet, AP HP, Clamart, France
[3] INSERM, Serv Epidemiol Demog & Sci Sociales, U822, F-94275 Le Kremlin Bicetre, France
[4] INSERM, U782, Clamart, France
[5] Univ Paris 11, UMR S0782, Clamart, France
关键词
Essure microinsert; hysteroscopic sterilization; hysterosalpingography; three-dimensional ultrasound; sterilization; 3D ultrasound; MICRO-INSERT; HYSTEROSCOPIC STERILIZATION; ESSURE STERILIZATION; PLACEMENT; DEVICE; CONFIRMATION;
D O I
10.1016/j.fertnstert.2010.03.056
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To assess the accuracy of three-dimensional (3D) ultrasound to determine the position of Essure microinserts. Design: Prospective observational study. Setting: Gynecology department in a teaching hospital. Patient(s): Forty women who underwent hysteroscopic sterilization from March through October 2008. Intervention(s): Both 3D ultrasound and hysterosalpingography (HSG) were performed 3 months after the procedure to verify device position. Positions seen on 3D ultrasound were classified in four categories: a perfect position (1 + 2 + 3), a proximal position (1 + 2), a distal position (2 + 3), and a very distal position (3-only). Main Outcome and Measure(s): Microinsert position on 3D ultrasound and correlation with HSG. Result(s): Overall, 93% of the devices for 40 patients were found to have been placed successfully. The final sample comprised 64 Essure devices. HSG showed tubal patency for only three devices, all classified as 3-only. No tubal permeability was noted for the other 61 positions. This 3-only location on 3D ultrasound was statistically associated with a failure of sterilization in comparison with the other locations (3/16 [18%] vs. 0/48 [0%]). Conclusion(s): 3D ultrasound is a simple and reproducible technique to assess the position of the Essure microinsert and appears to protect most patients from the negative aspects of pelvic radiography and of HSG. Using the 3D ultrasound classification presented in this study appears to make it possible to use HSG for backup confirmation only when Essure is found to be in the 3-only position on 3D ultrasound. (Fertil Steril (R) 2010;94:2732-5. (C) 2010 by American Society for Reproductive Medicine.)
引用
收藏
页码:2732 / 2735
页数:4
相关论文
共 50 条
[41]   BLADDER VOLUME DETERMINATION: TWO-DIMENSIONAL VERSUS THREE-DIMENSIONAL TRANSVAGINAL ULTRASOUND [J].
Liang, Ching-Chung ;
Wei, Tien-Yung ;
Chang, Shuenn-Dhy ;
Hsieh, Ching-Chang .
TAIWANESE JOURNAL OF OBSTETRICS & GYNECOLOGY, 2009, 48 (03) :258-261
[42]   Reproducibility of three-dimensional ultrasound for the measurement of a niche in a caesarean scar and assessment of its shape [J].
de Vaate, A. J. Marjolein Bij ;
Linskens, Ingeborg H. ;
van der Voet, Lucet F. ;
Twisk, Jos W. R. ;
Brolmann, Hans A. M. ;
Huirne, Judith A. F. .
EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2015, 188 :39-44
[43]   Criteria for three-dimensional anorectal ultrasound assessment of response to chemoradiotherapy in rectal cancer patients [J].
Murad-Regadas, S. M. ;
Regadas, F. S. P. ;
Rodrigues, L. V. ;
Crispin, F. J. ;
Kenmoti, V. T. ;
Fernandes, G. O. D. S. ;
Buchen, G. ;
Monteiro, F. C. C. .
COLORECTAL DISEASE, 2011, 13 (12) :1344-1350
[44]   Role of three-dimensional ultrasound in assessment of women undergoing urethral bulking agent therapy [J].
Poon, CI ;
Zimmern, PE .
CURRENT OPINION IN OBSTETRICS & GYNECOLOGY, 2004, 16 (05) :411-417
[45]   Three-dimensional ultrasound power Doppler assessment of the cervix: comparison between nulliparas and multiparas [J].
Basgul, Alin ;
Kavak, Zehra Nese ;
Bakirci, Nadi ;
Gokaslan, Husnu .
JOURNAL OF PERINATAL MEDICINE, 2007, 35 (01) :48-50
[46]   Unsupervised local feature learning for sensitive three-dimensional ultrasound assessment of carotid atherosclerosis [J].
Zhao, Yuan ;
Spence, J. David ;
Chiu, Bernard .
MEDICAL IMAGING 2020: IMAGE PROCESSING, 2021, 11313
[47]   Three-dimensional ultrasound in the assessment of fetal cerebellar transverse and antero-posterior diameters [J].
Chang, CH ;
Chang, FM ;
Yu, CH ;
Ko, HC ;
Chen, HY .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (02) :175-182
[48]   ASSESSMENT OF POSTOPERATIVE POSTVOID RESIDUAL BLADDER VOLUME USING THREE-DIMENSIONAL ULTRASOUND VOLUMETRY [J].
Bozsa, Szabolcs ;
Poto, Laszlo ;
Bodis, Jozsef ;
Halvax, Laszlo ;
Koppan, Miklos ;
Arany, Antal ;
Csermely, Tamas ;
Vizer, Miklos G. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (04) :522-529
[49]   Effect of sterilization processes on alginate/gelatin inks for three-dimensional printing [J].
Carranza, Teresa ;
Zalba-Balda, Martin ;
Barriola Baraibar, Mari Jose ;
de la Caba, Koro ;
Guerrero, Pedro .
INTERNATIONAL JOURNAL OF BIOPRINTING, 2023, 9 (01) :309-319
[50]   Three-dimensional ultrasound in the diagnosis and the classification of congenital uterine anomalies using the ESHRE/ESGE classification: a diagnostic accuracy study [J].
Kougioumtsidou, Anna ;
Mikos, Themistoklis ;
Grimbizis, Grigoris F. ;
Karavida, Aikaterini ;
Theodoridis, Theodoros D. ;
Sotiriadis, Alexandros ;
Tarlatzis, Basil C. ;
Athanasiadis, Apostolos P. .
ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2019, 299 (03) :779-789