Assessment of three-dimensional ultrasound examination classification to check the position of the tubal sterilization microinsert

被引:38
作者
Legendre, Guillaume [1 ,2 ,3 ]
Gervaise, Amelie [2 ]
Levaillant, Jean-Marc [2 ]
Faivre, Erika [2 ]
Deffieux, Xavier [2 ,4 ,5 ]
Fernandez, Herve [1 ,3 ,4 ,5 ]
机构
[1] Hop Bicetre, Serv Gynecol Obstet, AP HP, F-94275 Le Kremlin Bicetre, France
[2] Hop Antoine Beclere, Serv Gynecol Obstet, AP HP, Clamart, France
[3] INSERM, Serv Epidemiol Demog & Sci Sociales, U822, F-94275 Le Kremlin Bicetre, France
[4] INSERM, U782, Clamart, France
[5] Univ Paris 11, UMR S0782, Clamart, France
关键词
Essure microinsert; hysteroscopic sterilization; hysterosalpingography; three-dimensional ultrasound; sterilization; 3D ultrasound; MICRO-INSERT; HYSTEROSCOPIC STERILIZATION; ESSURE STERILIZATION; PLACEMENT; DEVICE; CONFIRMATION;
D O I
10.1016/j.fertnstert.2010.03.056
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To assess the accuracy of three-dimensional (3D) ultrasound to determine the position of Essure microinserts. Design: Prospective observational study. Setting: Gynecology department in a teaching hospital. Patient(s): Forty women who underwent hysteroscopic sterilization from March through October 2008. Intervention(s): Both 3D ultrasound and hysterosalpingography (HSG) were performed 3 months after the procedure to verify device position. Positions seen on 3D ultrasound were classified in four categories: a perfect position (1 + 2 + 3), a proximal position (1 + 2), a distal position (2 + 3), and a very distal position (3-only). Main Outcome and Measure(s): Microinsert position on 3D ultrasound and correlation with HSG. Result(s): Overall, 93% of the devices for 40 patients were found to have been placed successfully. The final sample comprised 64 Essure devices. HSG showed tubal patency for only three devices, all classified as 3-only. No tubal permeability was noted for the other 61 positions. This 3-only location on 3D ultrasound was statistically associated with a failure of sterilization in comparison with the other locations (3/16 [18%] vs. 0/48 [0%]). Conclusion(s): 3D ultrasound is a simple and reproducible technique to assess the position of the Essure microinsert and appears to protect most patients from the negative aspects of pelvic radiography and of HSG. Using the 3D ultrasound classification presented in this study appears to make it possible to use HSG for backup confirmation only when Essure is found to be in the 3-only position on 3D ultrasound. (Fertil Steril (R) 2010;94:2732-5. (C) 2010 by American Society for Reproductive Medicine.)
引用
收藏
页码:2732 / 2735
页数:4
相关论文
共 50 条
  • [21] Three-dimensional pelvic ultrasound is a practical tool for the assessment of anal fistula
    Junyi Ren
    Wenkun Bai
    Liangrui Gu
    Xiao Li
    Xue Peng
    WeiMei Li
    BMC Gastroenterology, 23
  • [22] Three-dimensional ultrasound for prenatal assessment of conjoined twins: additional advantages?
    Wataganara, Tuangsit
    Ruangvutilert, Pornpimol
    Sunsaneevithayakul, Prasert
    Russameecharoen, Kusol
    Nawapun, Katika
    Phithakwatchara, Nisarat
    JOURNAL OF PERINATAL MEDICINE, 2017, 45 (06) : 667 - 691
  • [23] The assessment of placental blood vessels by three-dimensional power Doppler ultrasound
    Matijevic, R
    Kurjak, A
    JOURNAL OF PERINATAL MEDICINE, 2002, 30 (01) : 26 - 32
  • [24] Assessment of normal fetal upper arm volume by three-dimensional ultrasound
    Chang, CH
    Yu, CH
    Chang, FM
    Ko, HC
    Chen, HY
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (07) : 859 - 863
  • [25] Examination of the fetal brain by transabdominal three-dimensional ultrasound:: potential for routine neurosonographic studies
    Correa, F. F.
    Lara, C.
    Bellver, J.
    Remohi, J.
    Pellicer, A.
    Serra, V.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 27 (05) : 503 - 508
  • [26] Three-dimensional ultrasound in embryo transfer
    Baba, K
    Ishihara, O
    Hayashi, N
    Saitoh, M
    Taya, J
    Kinoshita, K
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2000, 16 (04) : 372 - 373
  • [27] Three-dimensional ultrasound in prenatal diagnosis
    Chaoui, Rabih
    Heling, Kai-Sven
    CURRENT OPINION IN OBSTETRICS & GYNECOLOGY, 2006, 18 (02) : 192 - 202
  • [28] Three-dimensional ultrasound in evaluating the fetus
    Dueckelmann, Anna M.
    Kalache, Karim D.
    PRENATAL DIAGNOSIS, 2010, 30 (07) : 631 - 638
  • [29] Limb deformities and three-dimensional ultrasound
    Kos, M
    Hafner, T
    Funduk-Kurjak, B
    Bozek, T
    Kurjak, A
    JOURNAL OF PERINATAL MEDICINE, 2002, 30 (01) : 40 - 47
  • [30] Role of Three-Dimensional Ultrasound in Gynecology
    Turkgeldi E.
    Urman B.
    Ata B.
    The Journal of Obstetrics and Gynecology of India, 2015, 65 (3) : 146 - 154