Determination of siloxanes in water samples employing graphene oxide/Fe3O4 nanocomposite as sorbent for magnetic solid-phase extraction prior to GC-MS

被引:17
|
作者
Costa dos Reis, Luciana [1 ,2 ,3 ]
Vidal, Lorena [1 ,2 ]
Canals, Antonio [1 ,2 ]
机构
[1] Univ Alicante, Dept Quim Analit Nutr & Bromatol, POB 99, E-03080 Alicante, Spain
[2] Univ Alicante, Inst Univ Mat, POB 99, E-03080 Alicante, Spain
[3] Minist Educ Brazil, CAPES Fdn, Brasilia, DF, Brazil
关键词
gas chromatography with mass spectrometry; magnetic solid-phase extraction; nanocomposites; siloxanes; water samples; CYCLIC VOLATILE METHYLSILOXANES; POLYCYCLIC AROMATIC-HYDROCARBONS; GAS-CHROMATOGRAPHY; WASTE-WATER; TREATMENT-PLANT; ORGANOCHLORINE PESTICIDES; MICROEXTRACTION; OXIDE; FATE; FABRICATION;
D O I
10.1002/jssc.201800577
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new, fast, simple, and environmentally friendly analytical method has been developed to determine six siloxanes in water samples: octamethyltrisiloxane, octamethylcyclotetrasiloxane, decamethyltetrasiloxane, decamethylcyclopentasiloxane, dodecamethylpentasiloxane and dodecamethylcyclohexasiloxane. The analytical method consists of magnetic solid-phase extraction employing graphene oxide/Fe3O4 as sorbent for the separation and preconcentration of siloxanes prior to GC-MS determination. The extraction procedure was optimized by means of a Plackett-Burman design. Under the optimized extraction conditions (graphene oxide/Fe3O4, 20 mg; extraction time, 10 min; eluent volume, 0.5 mL ACN; elution time, 2.5 min; sample volume, 20 mL), the method rendered repeatability levels with a relative standard deviation between 9 and 20% (n = 6, 10 mu g/L). Methodological limits of detection ranged from 0.003 to 0.1 mu g/L. The linearity of the method was studied between the methodological limit of quantification and 100 mu g/L, obtaining correlation coefficient values between 0.990 and 0.999. The applicability of the method was assessed by analyzing drinking, river and wastewater samples. Relative recovery values ranged between 70 and 120% (1 and 60 mu g/L spiking level) showing that the matrix had a negligible effect on extraction. Finally, the greenness of this method was confirmed by the semiquantitative Eco-Scale metrics.
引用
收藏
页码:4177 / 4184
页数:9
相关论文
共 50 条
  • [1] Magnetic solid-phase extraction of caffeine from surface water samples with a micro-meso porous activated carbon/Fe3O4 nanocomposite prior to its determination by GC-MS
    Manousi, Natalia
    Deliyanni, Eleni A.
    Rosenberg, Erwin
    Zachariadis, George A.
    RSC ADVANCES, 2021, 11 (32) : 19492 - 19499
  • [2] Magnetic solid-phase extraction of imatinib and doxorubicin as cytostatic drugs by Fe3O4/graphene oxide nanocomposite
    Majid Arvand
    Afshin Nickdoust Masouleh
    Journal of the Iranian Chemical Society, 2017, 14 : 1673 - 1682
  • [3] Magnetic solid-phase extraction of imatinib and doxorubicin as cytostatic drugs by Fe3O4/graphene oxide nanocomposite
    Arvand, Majid
    Masouleh, Afshin Nickdoust
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2017, 14 (08) : 1673 - 1682
  • [4] A nanocomposite consisting of poly(methyl methacrylate), graphene oxide and Fe3O4 nanoparticles as a sorbent for magnetic solid-phase extraction of aromatic amines
    Bashtani, Elham
    Amiri, Amirhassan
    Baghayeri, Mehdi
    MICROCHIMICA ACTA, 2018, 185 (01)
  • [5] A nanocomposite consisting of poly(methyl methacrylate), graphene oxide and Fe3O4 nanoparticles as a sorbent for magnetic solid-phase extraction of aromatic amines
    Elham Bashtani
    Amirhassan Amiri
    Mehdi Baghayeri
    Microchimica Acta, 2018, 185
  • [6] Graphene oxide/Fe3O4 as sorbent for magnetic solid-phase extraction coupled with liquid chromatography to determine 2,4,6-trinitrotoluene in water samples
    Luciana Costa dos Reis
    Lorena Vidal
    Antonio Canals
    Analytical and Bioanalytical Chemistry, 2017, 409 : 2665 - 2674
  • [7] Graphene oxide/Fe3O4 as sorbent for magnetic solid-phase extraction coupled with liquid chromatography to determine 2,4,6-trinitrotoluene in water samples
    Costa dos Reis, Luciana
    Vidal, Lorena
    Canals, Antonio
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (10) : 2665 - 2674
  • [8] Experimental and molecular docking study on graphene/Fe3O4 composites as a sorbent for magnetic solid-phase extraction of seven imidazole antifungals in environmental water samples prior to LC-MS/MS for enantiomeric analysis
    Wang, Zhaokun
    Zhao, Pengfei
    Yu, Jia
    Jiang, Zhen
    Guo, Xingjie
    MICROCHEMICAL JOURNAL, 2018, 140 : 222 - 231
  • [9] Determination of sulfadimethoxine in milk with aptamer-functionalized Fe3O4/graphene oxide as magnetic solid-phase extraction adsorbent prior to HPLC
    Guo, Yinan
    Wei, Wei
    Zhang, Ying
    Dai, Yuanyuan
    Wang, Weiping
    Wang, Aijun
    JOURNAL OF SEPARATION SCIENCE, 2020, 43 (17) : 3499 - 3508
  • [10] Magnetic solid-phase extraction based on Fe3O4/graphene oxide nanoparticles for the determination of malachite green and crystal violet in environmental water samples by HPLC
    Zhang, Leilei
    Zhang, Yiying
    Tang, Yurong
    Li, Xiaorong
    Zhang, Xinfeng
    Li, Chaobi
    Xu, Shuxia