Determination of siloxanes in water samples employing graphene oxide/Fe3O4 nanocomposite as sorbent for magnetic solid-phase extraction prior to GC-MS

被引:17
作者
Costa dos Reis, Luciana [1 ,2 ,3 ]
Vidal, Lorena [1 ,2 ]
Canals, Antonio [1 ,2 ]
机构
[1] Univ Alicante, Dept Quim Analit Nutr & Bromatol, POB 99, E-03080 Alicante, Spain
[2] Univ Alicante, Inst Univ Mat, POB 99, E-03080 Alicante, Spain
[3] Minist Educ Brazil, CAPES Fdn, Brasilia, DF, Brazil
关键词
gas chromatography with mass spectrometry; magnetic solid-phase extraction; nanocomposites; siloxanes; water samples; CYCLIC VOLATILE METHYLSILOXANES; POLYCYCLIC AROMATIC-HYDROCARBONS; GAS-CHROMATOGRAPHY; WASTE-WATER; TREATMENT-PLANT; ORGANOCHLORINE PESTICIDES; MICROEXTRACTION; OXIDE; FATE; FABRICATION;
D O I
10.1002/jssc.201800577
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new, fast, simple, and environmentally friendly analytical method has been developed to determine six siloxanes in water samples: octamethyltrisiloxane, octamethylcyclotetrasiloxane, decamethyltetrasiloxane, decamethylcyclopentasiloxane, dodecamethylpentasiloxane and dodecamethylcyclohexasiloxane. The analytical method consists of magnetic solid-phase extraction employing graphene oxide/Fe3O4 as sorbent for the separation and preconcentration of siloxanes prior to GC-MS determination. The extraction procedure was optimized by means of a Plackett-Burman design. Under the optimized extraction conditions (graphene oxide/Fe3O4, 20 mg; extraction time, 10 min; eluent volume, 0.5 mL ACN; elution time, 2.5 min; sample volume, 20 mL), the method rendered repeatability levels with a relative standard deviation between 9 and 20% (n = 6, 10 mu g/L). Methodological limits of detection ranged from 0.003 to 0.1 mu g/L. The linearity of the method was studied between the methodological limit of quantification and 100 mu g/L, obtaining correlation coefficient values between 0.990 and 0.999. The applicability of the method was assessed by analyzing drinking, river and wastewater samples. Relative recovery values ranged between 70 and 120% (1 and 60 mu g/L spiking level) showing that the matrix had a negligible effect on extraction. Finally, the greenness of this method was confirmed by the semiquantitative Eco-Scale metrics.
引用
收藏
页码:4177 / 4184
页数:9
相关论文
共 38 条
[1]  
[Anonymous], 1031 DAN EPA
[2]  
[Anonymous], 2009, DESIGN ANAL EXPT
[3]   Principles and potential of the anaerobic digestion of waste-activated sludge [J].
Appels, Lise ;
Baeyens, Jan ;
Degreve, Jan ;
Dewil, Raf .
PROGRESS IN ENERGY AND COMBUSTION SCIENCE, 2008, 34 (06) :755-781
[4]   Mass Loading and Fate of Linear and Cyclic Siloxanes in a Wastewater Treatment Plant in Greece [J].
Bletsou, Anna A. ;
Asimakopoulos, Alexandros G. ;
Stasinakis, Athanasios S. ;
Thomaidis, Nikolaos S. ;
Kannan, Kurunthachalam .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (04) :1824-1832
[5]   Fabrication of magnetically separable palladium-graphene nanocomposite with unique catalytic property of hydrogenation [J].
Chandra, Sourov ;
Bag, Sourav ;
Das, Pradip ;
Bhattacharya, Dipsikha ;
Pramanik, Panchanan .
CHEMICAL PHYSICS LETTERS, 2012, 519-20 :59-63
[6]   Preparation and evaluation of graphene-coated solid-phase microextraction fiber [J].
Chen, Jinmei ;
Zou, Jing ;
Zeng, Jingbin ;
Song, Xinhong ;
Ji, Jiaojiao ;
Wang, Yiru ;
Ha, Jaeho ;
Chen, Xi .
ANALYTICA CHIMICA ACTA, 2010, 678 (01) :44-49
[7]   Analysis of linear and cyclic methylsiloxanes in water by headspace-solid phase microextraction and gas chromatography-mass spectrometry [J].
Companioni-Damas, E. Y. ;
Santos, F. J. ;
Galceran, M. T. .
TALANTA, 2012, 89 :63-69
[8]   Determination of cyclic and linear siloxanes in wastewater samples by ultrasound-assisted dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry [J].
Cortada, Carol ;
Costa dos Reis, Luciana ;
Vidal, Lorena ;
Llorca, Julio ;
Canals, Antonio .
TALANTA, 2014, 120 :191-197
[9]   Determination of organochlorine pesticides in complex matrices by single-drop microextraction coupled to gas chromatography-mass spectrometry [J].
Cortada, Carol ;
Vidal, Lorena ;
Tejada, Sergio ;
Romo, Alicia ;
Canals, Antonio .
ANALYTICA CHIMICA ACTA, 2009, 638 (01) :29-35
[10]   Graphene oxide/Fe3O4 as sorbent for magnetic solid-phase extraction coupled with liquid chromatography to determine 2,4,6-trinitrotoluene in water samples [J].
Costa dos Reis, Luciana ;
Vidal, Lorena ;
Canals, Antonio .