Posterior pelvic ring fractures: Intraoperative 3D-CT guided navigation for accurate positioning of sacro-iliac screws

被引:34
作者
Ghisla, Simone [1 ]
Napoli, Francesca [1 ]
Lehoczky, Gyozo [2 ]
Delcogliano, Marco [1 ]
Habib, Nermine [1 ]
Arigoni, Michele [3 ]
Filardo, Giuseppe [4 ]
Candrian, Christian [1 ]
机构
[1] Reg Hosp Lugano EOC, Orthopaed & Traumatol Unit, Via Tesserete 46, CH-6900 Lugano, Switzerland
[2] Univ Hosp Basel, Orthopaed & Traumatol Dept, Basel, Switzerland
[3] Reg Hosp Locarno EOC, Surg Dept, Locarno, Switzerland
[4] IRCCS, Rizzoli Orthopaed Inst, Bologna, Italy
关键词
Posterior pelvic ring fracture; Sacro-liac screws fixation; O-Arm(C); ILIOSACRAL SCREWS; O-ARM; RETROSPECTIVE ANALYSIS; REVISION RATES; EARLY FIXATION; PLACEMENT; SPINE; FLUOROSCOPY; INSERTION; SURGERY;
D O I
10.1016/j.otsr.2018.07.006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Posterior pelvic ring fractures frequently pose a problem of stability with an elevated risk of complications. The traditional method of percutaneous sacroiliac (SI) stabilization with the use of fluoroscopic image amplifiers demands a high degree of experience and has an elevated risk of screws' malpositioning. Hypothesis: Intraoperative 3D-CT scan coupled with a navigation system (OArm(C)) can allow screw fixation accuracy while limiting the risk of complications for the treatment of posterior pelvic ring fractures. Material and methods: Patients with posterior pelvic ring fractures stabilized with percutaneous SI screws through O-Arm(C) navigation from August 2008 to December 2017 were analyzed. A modified Gras classification was used to determine screws' positioning under CT visualization, and intraoperative and early postoperative complications were documented. Results: Among the 21 patients evaluated, 14 men and 7 women with a mean age of 57.8 years (range 25-91), receiving 39 screws, the rate of misplacement was low: 82% grade I, 15.4% grade II, and only 2.6% grade III. Only one patient underwent revision surgery, not because of misplacement but rather for a secondary implant loosening. No complications occurred in this series. Discussion: This study documented a large series of patients treated for pelvic ring fractures using the intraoperative 3D-CT O-Arm(C) guided navigation. This surgical approach provided a precise and safe SI screw positioning with no complications. (C) 2018 Published by Elsevier Masson SAS.
引用
收藏
页码:1063 / 1067
页数:5
相关论文
共 30 条
  • [1] Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine
    Amiot, LP
    Lang, K
    Putzier, M
    Zippel, H
    Labelle, H
    [J]. SPINE, 2000, 25 (05) : 606 - 614
  • [2] Computer-guidance in percutaneous screw stabilization of the iliosacral joint
    Arand, M
    Kinzl, L
    Gebhard, F
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (422) : 201 - 207
  • [3] Fracture Surgery of the extremities with the intra-operative use of 3D-RX: A randomized multicenter trial (EF3X-trial)
    Beerekamp, M. Suzan H.
    Ubbink, Dirk Th
    Maas, Mario
    Luitse, Jan S. K.
    Kloen, Peter
    Blokhuis, Taco J. M.
    Segers, Michiel J. M.
    Marmor, Meir
    Schep, Niels W. L.
    Dijkgraaf, Marcel G. W.
    Goslings, J. Carel
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2011, 12
  • [4] PELVIC RING DISRUPTIONS - EFFECTIVE CLASSIFICATION-SYSTEM AND TREATMENT PROTOCOLS
    BURGESS, AR
    EASTRIDGE, BJ
    YOUNG, JWR
    ELLISON, TS
    ELLISON, PS
    POKA, A
    BATHON, GH
    BRUMBACK, RJ
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1990, 30 (07) : 848 - 856
  • [5] Percutaneous iliosacral screw fixation in unstable pelvic ring lesions: The interest of O-ARM CT-guided navigation
    Coste, C.
    Asloum, Y.
    Marcheix, P. S.
    Dijoux, P.
    Charissoux, J. L.
    Mabit, C.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2013, 99 (04) : S273 - S278
  • [6] DENIS F, 1988, CLIN ORTHOP RELAT R, P67
  • [7] UNSTABLE FRACTURES OF THE PELVIC RING
    FAILINGER, MS
    MCGANITY, PLJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (05) : 781 - 791
  • [8] 2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series
    Gras, Florian
    Marintschev, Ivan
    Wilharm, Arne
    Klos, Kajetan
    Mueckley, Thomas
    Hofmann, Gunther O.
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2010, 11
  • [9] Hinsche AF, 2002, CLIN ORTHOP RELAT R, P135
  • [10] Percutaneous Sacroiliac Screw Fixation of the Posterior Pelvic Ring
    Iorio, Justin A.
    Jakoi, Andre M.
    Rehman, Saqib
    [J]. ORTHOPEDIC CLINICS OF NORTH AMERICA, 2015, 46 (04) : 511 - +