In vitro mechanical property comparison of four resins used for fabrication of provisional fixed restorations

被引:50
作者
Ireland, MF
Dixon, DL
Breeding, LC
Ramp, MH
机构
[1] Univ Alabama Birmingham, Sch Dent, Dept Restorat Dent, Birmingham, AL 35294 USA
[2] Univ Kentucky, Coll Dent, Dept Oral Hlth Practice, Lexington, KY USA
关键词
D O I
10.1016/S0022-3913(98)70104-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose. This study recorded and compared the flexural elastic moduli and moduli of rupture of four materials (Provipont DC resin, Triad provisional restorative material, Tet acrylic resin, and a 50:50 mixture of Jet acrylic resin and orthodontic resin) used to make provisional restorations. Material and methods. Thirty-nine identical 63 x 10 x 3 mm specimens were made from each of the four materials. After 24 hours, 30 days, and 60 days of water storage at 37 degrees C (13 specimens each), standard three-point bend tests were conducted on an Instron universal testing machine at a crosshead speed of 0.5 cm/minute. Stress strain curves were generated, and values for the flexural elastic moduli and moduli of rupture were calculated. Data were subjected to two-way and one-way analyses of variance (alpha = 0.05). Results. Provipont DC resin exhibited significantly higher flexural elastic moduli and moduli of rupture values at the 24-hour test time. However, Provipont DC resin exhibited the greatest decrease in these values over time.
引用
收藏
页码:158 / 162
页数:5
相关论文
共 8 条