Effect of Error in SO2 Slant Column Density on the Accuracy of SO2 Transport Flow Rate Estimates Based on GEMS Synthetic Radiances

被引:4
作者
Park, Junsung [1 ]
Choi, Wonei [1 ]
Lee, Hyung-Min [2 ,3 ]
Park, Rokjin J. [2 ]
Kim, Seong-Yeon [4 ]
Yu, Jeong-Ah [4 ]
Lee, Dong-Won [4 ]
Lee, Hanlim [1 ]
机构
[1] Pukyong Natl Univ, Div Earth Environm Syst Sci, Major Spatial Informat Engn, Yongso Ro 45, Busan 48513, South Korea
[2] Seoul Natl Univ, Sch Earth & Environm Sci, Gwanak Ro 1, Seoul 08826, South Korea
[3] Ewha Womans Univ, Dept Environm Sci & Engn, Ewhayeodae Gil 52, Seoul 03760, South Korea
[4] Natl Inst Environm Res, Hwangyong Ro 42, Incheon 22689, South Korea
关键词
SO2; flow rate; geostationary environment monitoring spectrometer (GEMS); long-range transport; SULFUR-DIOXIDE; ANTHROPOGENIC EMISSIONS; GREENHOUSE GASES; ACID DEPOSITION; AIR-POLLUTANTS; SOUTH-KOREA; CHINA; MODEL; INVENTORY; PRECIPITATION;
D O I
10.3390/rs13153047
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study investigates the uncertainties associated with estimates of the long-range transport SO2 (LRT-SO2) flow rate calculated hourly using Geostationary Environment Monitoring Spectrometer (GEMS) synthetic radiances. These radiances were simulated over the Korean Peninsula and the surrounding regions using inputs from the GEOS-Chem model for January, April, July, and October 2016. The LRT-SO2 calculation method, which requires SO2 vertical column densities, wind data, and planetary boundary layer information, was used to quantify the effects of the SO2 slant column density (SCD) retrieval error and uncertainties in wind data on the accuracy of the LRT-SO2 estimates. The effects were estimated for simulations of three anthropogenic and three volcanic SO2 transport events. When there were no errors in the GEMS SO2 SCD and wind data, the average true LRT-SO2 flow rates (standard deviation) and those calculated for these events were 1.17 (+/- 0.44) and 1.21 (+/- 0.44) Mg/h, respectively. However, the averages of the true LRT-SO2 flow rates and those calculated for the three anthropogenic (volcanic) SO2 events were 0.61 (1.17) and 0.64 (1.20) Mg/h, respectively, in the presence of GEMS SO2 SCD errors. In the presence of both errors in the GEMS SO2 SCD and wind data, the averages of the true LRT-SO2 flow rates and those calculated for the three anthropogenic (volcanic) SO2 events were 0.61 (1.17) and 0.61 (1.04) Mg/h, respectively. This corresponds to differences of 2.1% to 23.1% between the simulated and true mean LRT-SO2 flow rates. The mean correlation coefficient (R), intercept, and slope between the true and simulated LRT-SO2 flow rates were 0.51, 0.43, and 0.45 for the six simulated events, respectively. This study demonstrates that SO2 SCD accuracy is an important factor in improving estimates of LRT-SO2 flow rates.
引用
收藏
页数:28
相关论文
共 31 条
  • [31] Insight into the effect of the continuous testing and aging on the SO2 sensing characteristics of a YSZ (Yttria-stabilized Zirconia)-based sensor utilizing ZnGa2O4 and Pt electrodes
    Hao, Xidong
    Lu, Qi
    Zhang, Yuxi
    Li, Weijia
    Zhang, Yueying
    Liu, Tong
    Liang, Xishuang
    Liu, Fangmeng
    Yan, Xu
    Gao, Yuan
    Wang, Lang
    Lu, Geyu
    JOURNAL OF HAZARDOUS MATERIALS, 2020, 388