Experimental research of the thermal characteristics of a multi-storey naturally ventilated double skin facade

被引:49
作者
Andelkovic, Aleksandar S. [1 ]
Gvozdenac-Urosevic, Branka [1 ]
Kljajic, Miroslav [1 ]
Ignjatovic, Marko G. [2 ]
机构
[1] Univ Novi Sad, Fac Tech Sci, Novi Sad 21000, Serbia
[2] Univ Nis, Fac Mech Engn, Nish 14000, Serbia
关键词
Experimental technique; Multi-storey building; Naturally ventilated double skin facade; Thermal characteristics; Enthalpy flow; Thermography techniques; BUILDINGS; PERSPECTIVES;
D O I
10.1016/j.enbuild.2014.11.007
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study presents the results of the actual thermal behaviour of a multi-storey naturally ventilated double skin facade. Governed by lack of experimentally measured data, a field of detailed measurements were performed during the 2013/2014 season in the office building located in Belgrade, Serbia. The uniqueness of this building is that the first facade layer is made in the tradition manner. Apart from studying classical environmentally influenced air cavity behaviour, the methodology incorporates a detailed analysis of the air cavity enthalpy flow. The main purpose of this research is to examine the current state of the building facade and how it affects energy performance. To this effect, measurement data was used in order to analyse transmission losses and gains and to quantify enthalpy change of the cavity air linked to the airflow established within the facade. Analyse of the transmission losses and gains were described by a series of diagrams of vertical and horizontal temperatures trends for selected typical days in each regime. For investigation of the natural ventilation potential, an adequate indicator based on the enthalpy change was established. Overall, the experiment results highlight that the use of a double skin facade does not necessarily reduce energy consumption. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:766 / 781
页数:16
相关论文
共 29 条
[1]  
[Anonymous], 1998, 13187 EN
[2]  
[Anonymous], 2013, TECHNOLOGY ROADMAP E
[3]   Perspectives of double skin facades for naturally ventilated buildings: A review [J].
Barbosa, Sabrina ;
Ip, Kenneth .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 40 :1019-1029
[4]   Operation and control strategies for multi-storey double skin facades during the heating season [J].
Choi, Wonjun ;
Joe, Jaewan ;
Kwak, Younghoon ;
Huh, Jung-Ho .
ENERGY AND BUILDINGS, 2012, 49 :454-465
[5]   Are energy consumptions decreased with the addition of a double-skin? [J].
Gratia, Elisabeth ;
De Herde, Andre .
ENERGY AND BUILDINGS, 2007, 39 (05) :605-619
[6]   Quantitative infrared thermography in buildings [J].
Grinzato, E ;
Vavilov, V ;
Kauppinen, T .
ENERGY AND BUILDINGS, 1998, 29 (01) :1-9
[7]   Simulation of ventilated facades in hot and humid climates [J].
Haase, M. ;
da Silva, F. Marques ;
Amato, A. .
ENERGY AND BUILDINGS, 2009, 41 (04) :361-373
[8]   Thermal behaviour of a ventilated double skin facade in hot arid climate [J].
Hashemi, N. ;
Fayaz, R. ;
Sarshar, M. .
ENERGY AND BUILDINGS, 2010, 42 (10) :1823-1832
[9]   Building simulation as an assisting tool in decision making - Case study: With or without a double-skin facade? [J].
Hoseggen, R. ;
Wachenfeldt, B. J. ;
Hanssen, S. O. .
ENERGY AND BUILDINGS, 2008, 40 (05) :821-827
[10]   Optimal design of a multi-story double skin facade [J].
Joe, Jaewan ;
Choi, Wonjun ;
Kwak, Younghoon ;
Huh, Jung-Ho .
ENERGY AND BUILDINGS, 2014, 76 :143-150