Finite Element Analysis of Eustachian Tube Function in Cleft Palate Infants Based on Histological Reconstructions

被引:13
作者
Sheer, F. J. [2 ]
Swarts, J. D. [3 ]
Ghadiali, S. N. [1 ]
机构
[1] Ohio State Univ, Dept Internal Med, Dept Biomed Engn, Div Pulm Allergy Crit Care & Sleep Med, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Mech Engn, Columbus, OH 43210 USA
[3] Childrens Hosp Pittsburgh, Dept Pediat Otolaryngol, Pittsburgh, PA 15213 USA
关键词
cleft palate infants; eustachian tube function; finite element models; TENSOR VELI PALATINI; OTITIS-MEDIA; MUSCLE; PALATOPLASTY; MORPHOLOGY; FURLOW; MODEL; CARTILAGE; CHILDREN; FRACTURE;
D O I
10.1597/09-131
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction The prevalence of otitis media with effusion approaches 100% in infants with cleft palate (CP), and disease pathogenesis is believed to be caused by eustachian tube (ET) dysfunction Objectives Quantify the functional consequences of ET anatomy in infant CP specimens, and identify the relative importance of various tissue biomechanical properties on ET function in infants with CP Methods Finite element models of ET anatomy and physiology were developed by using image analysis and three-dimensional (3D) reconstruction techniques Models were developed using histological images of ET structures obtained from five infant CP specimens The models were parameterized, and the effects of varying model parameters, which included tensor veli palatini and levator veli palatini force, ET cartilage, periluminal mucosal compliance, and hamular position on resistance to airflow through the tubal lumen, were determined Results Of the evaluated parameters, only applied tensor veli palatini muscle force and compliance of the periluminal mucosa and cartilage tissues were significant predictors of resistance to airflow through the ET during muscle-assisted opening Conclusions Finite element models of ET function in the CP infant identified tensor veil palatini muscle force as a direct predictor and mucosal/cartilage compliance as an indirect predictor of ET opening during muscle-assisted lumen dilations Hamular position and levator veli palatini force were not found to have an effect on ET function in CP infants
引用
收藏
页码:600 / 610
页数:11
相关论文
共 50 条
  • [31] A state-based peridynamic analysis in a finite element framework
    Madenci, Erdogan
    Dorduncu, Mehmet
    Barut, Atila
    Nam Phan
    ENGINEERING FRACTURE MECHANICS, 2018, 195 : 104 - 128
  • [32] Efficacy of Ventilation Tube Insertion with Palatal Repair for Otitis Media in Cleft Palate: Meta-Analysis and Trial Sequential Analysis
    Chang, Feng-Liang
    Chen, Chih-Hao
    Cheng, Hsiu-Lien
    Chang, Chun-Yu
    Leong, Jing-Li
    Chang, Yen-Ting
    Cheng, Yen-Fu
    Liao, Wen-Huei
    JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (02):
  • [33] Palatoplasty decreases the re-insertion rate of middle ear ventilation tube in cleft palate children - A population-based birth cohort study
    Huang, Chii-Yuan
    Wu, Chuan-Song
    Tang, Chao-Hsiun
    Wang, Mao-Che
    Kuo, Ting-Yu
    Tu, Tzong-Yang
    ACTA OTO-LARYNGOLOGICA, 2016, 136 (08) : 768 - 774
  • [34] Patient Factors Influencing Speech Outcomes in Velopharyngeal Function Following Initial Cleft Palate Repair: A Systematic Review and Meta-Analysis
    Sainsbury, David C. G.
    Williams, Caroline C.
    Butterworth, Sophie
    de Blacam, Catherine
    Fell, Matthew J. J.
    Mullen, Joanne
    Breakey, William
    Murphy, Colm
    Hodgkinson, Peter D. D.
    Wren, Yvonne
    CLEFT PALATE CRANIOFACIAL JOURNAL, 2024, 61 (12) : 2022 - 2037
  • [35] Maxillary reaction patterns identified by three-dimensional analysis of casts from infants with unilateral cleft lip and palate
    Neuschulz, Julia
    Schaefer, Isabelle
    Scheer, Martin
    Christ, Hildegard
    Braumann, Bert
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2013, 74 (04): : 275 - +
  • [36] REPRODUCE DIAMETER REDUCTION PROCESS OF A POWDER FILLED TUBE IN FINITE ELEMENT ANALYSIS
    Boeck, B.
    Buchmayr, B.
    Wallner, S.
    Posch, G.
    COMPUTATIONAL PLASTICITY XI: FUNDAMENTALS AND APPLICATIONS, 2011, : 1145 - 1152
  • [37] Residual Stress Impairs Pump Function After Surgical Ventricular Remodeling: A Finite Element Analysis
    Pantoja, Joe Luis
    Zhang, Zhihong
    Tartibi, Mehrzad
    Sun, Kay
    Macmillan, Warrick
    Guccione, Julius M.
    Ge, Liang
    Ratcliffe, Mark B.
    ANNALS OF THORACIC SURGERY, 2015, 100 (06) : 2198 - 2205
  • [38] Sequential coupling simulation for electromagnetic-mechanical tube compression by finite element analysis
    Haiping, Y. U.
    Chunfeng, L. I.
    Jianghua, D. E. N. G.
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2009, 209 (02) : 707 - 713
  • [39] Implicit elastoplastic finite element analysis of tube-bending with an emphasis on springback prediction
    Razali, Nurul Aqilah
    Chung, Suk Hwan
    Chung, Wan Jin
    Joun, Man Soo
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2022, 120 (9-10) : 6377 - 6391
  • [40] An integrated finite element simulation of cardiomyocyte function based on triphasic theory
    Hatano, Asuka
    Okada, Jun-Ichi
    Washio, Takumi
    Hisada, Toshiaki
    Sugiura, Seiryo
    FRONTIERS IN PHYSIOLOGY, 2015, 6