Air radon equilibrium factor measurement in a Waste Water Pre-Treatment Plant

被引:3
|
作者
Martinez, J. E. [1 ]
Juste, B. [1 ]
Ortiz, J. [2 ]
Martorell, S. [2 ]
Verdu, G. [1 ]
机构
[1] Univ Politecn Valencia, Inst Seguridad Ind Radiofis & Medioambiental, Card Vera S-N, E-46022 Valencia, Spain
[2] Univ Politecn Valencia, Lab Radioactividad Ambiental, Cami Vera S-N, E-46022 Valencia, Spain
关键词
Radon; Equilibrium factor; Gamma spectroscopy; Bateman equation; Radon progeny;
D O I
10.1016/j.radphyschem.2017.03.011
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
We analyze in this paper a Waste Water Pre-Treatment Plant (WWTP) located at the Mediterranean coast with air radon concentration above Spanish action level (600 Bq per cubic meter). This paper presents a method for radon equilibrium determination by gamma spectrometry measuring of the radon progeny concentrations in the air, in order to estimate WWTP workers effective dose more exactly. The method is based on simultaneous sampling of air through a filter paper and alpha spectrometry measurement of radon activity concentration in the air. According to the measured radon activity concentration in the air of 368 +/- 45 Bq/m(3) the equilibrium factor between radon and progenies is estimated to be F=0.27, which is in good agreement with expected values.
引用
收藏
页码:20 / 24
页数:5
相关论文
共 8 条
  • [1] Developing a novelty method to estimate radon doses in a Waste Water Pre-Treatment Plant
    Martinez, J. E.
    Juste, B.
    Verdu, G.
    Miro, R.
    Ortiz, J.
    Martorell, S.
    RADIATION PHYSICS AND CHEMISTRY, 2019, 155 : 323 - 327
  • [2] RADON EQUILIBRIUM MEASUREMENT IN THE AIR
    Forkapic, Sofija
    Mrda, Dusan
    Veskovic, Miroslav
    Todorovic, Natasa
    Bikit, Kristina
    Nikolov, Jovana
    Hansman, Jan
    ROMANIAN JOURNAL OF PHYSICS, 2013, 58 : S140 - S147
  • [3] Radon equilibrium factor and perceived air quality in an air-conditioned auditorium in Lublin, Poland
    Polednik, Bernard
    Kozak, Krzysztof
    Mazur, Jadwiga
    Dudzinska, Marzenna
    Grzadziel, Dominik
    Polednik, Aleksandra
    INDOOR AND BUILT ENVIRONMENT, 2018, 27 (02) : 270 - 277
  • [4] Measurement of the equilibrium factor between radon and its progeny in the underground mining environment
    Ntwaeaborwa, OM
    Kgwadi, ND
    Taole, SH
    Strydom, R
    HEALTH PHYSICS, 2004, 86 (04): : 374 - 377
  • [5] Radon in water measurement system based on the membrane-based air water separation method
    Lee, ChoongWie
    Bae, Jun Woo
    Kim, Hee Reyoung
    Heo, Pil Woo
    Chae, Hyeon-Sik
    RADIATION MEASUREMENTS, 2019, 121 : 54 - 60
  • [6] Measurement of equilibrium factor "F" between radon and its progeny and thoron and its progeny in the indoor atmosphere using nuclear track detectors
    Ramola, RC
    Negi, MS
    Choubey, VM
    INDOOR AND BUILT ENVIRONMENT, 2003, 12 (05) : 351 - 355
  • [7] Measurement of radon daughters in water and in air using the detection unit "YAPMARE'with a YAP:Ce scintillation detector
    Thinova, L
    Kunka, A
    Maly, P
    de Notaristefani, F
    Blazek, K
    Trojek, T
    Moucka, L
    HIGH LEVELS OF NATURAL RADIATION AND RADON AREAS: RADIATION DOSE AND HEALTH EFFECTS, 2005, 1276 : 383 - 384
  • [8] Direct measurement of indoor thoron and radon progeny and estimation of inhalation dose in three cities in Gabon: Comparison of the use of thoron typical and measured equilibrium factor values
    Mouandza, Sylvere Yannick Loemba
    Saidou
    Ndong, W.
    Kranrod, Chutima
    Hosoda, Masahiro
    Meye, P. Ondo
    Djeune, R. Bipolo
    Mombo, E. -D. Durastanti-Rabenga
    Andeme-Abondhoume, H. M. -J.
    Ndjembidouma, B. C. Mabika
    Ekogo, T. B.
    Ben-Bolie, G. H.
    Tokonami, Shinji
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2024, 280