Evaluation of hydrophilic interaction liquid chromatography, capillary zone electrophoresis and drift tube ion-mobility quadrupole time of flight mass spectrometry for the characterization of phosphodiester and phosphorothioate oligonucleotides

被引:35
作者
Demelenne, Alice [1 ]
Gou, Marie-Jia [1 ]
Nys, Gwenael [1 ]
Parulski, Chloe [1 ]
Crommen, Jacques [1 ]
Servais, Anne-Catherine [1 ]
Fillet, Marianne [1 ]
机构
[1] Univ Liege, Quartier Hosp, CIRM, Lab Anal Med, Ave Hippocrate 15, B-4000 Liege, Belgium
关键词
Optimization; High resolution mass spectrometry; Nucleic acids; Collision cross section; Quality control; DNA OLIGONUCLEOTIDES; SEPARATION;
D O I
10.1016/j.chroma.2019.460716
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Oligonucleotide-based medicines that can modulate gene expression have numerous potential applications in targeted therapies. Most of the commercialized therapeutic oligonucleotides are chemically modified to increase their in vivo lifetime. In this work, we studied poly-deoxy(thymidylic) acids (dT) and modified phosphorothioate oligonucleotides (PS). Several analytical techniques, including ion-pair reverse phase liquid chromatography, are described in the literature to assess their quality but most of them present significant drawbacks. In the present study, dT and PS mixtures were analyzed by hydrophilic interaction liquid chromatography (HILIC) and capillary zone electrophoresis (CZE) coupled to ultraviolet detection. In HILIC, the selectivities of three types of stationary phases (dihydroxypropane, phosphorylcholine and amide) were compared. Optimal conditions were determined and consisted of an amide stationary phase with a mobile phase made up of water, acetonitrile and 15 mM ammonium acetate (pH 5.5). In those conditions, high resolving power and good repeatability were achieved. In CZE, the effect of the background electrolyte (BGE), its pH and concentration were evaluated. A BGE made up of 300 mM ammonium acetate adjusted to pH 6.0 was selected. Finally, the two techniques were compared in terms of selectivity, repeatability and peak efficiency. In the second part of the study, HILIC and CZE were both coupled to a drift-tube ion-mobility quadrupole time-of-flight MS detector (DTIMS-QTOF) to assess the added value of this coupling for oligonucleotide characterization. Indeed, by using the measured collision cross section (CCS), the evaluation of the number of nucleotides was performed. Looking across the results, HILIC and CZE coupled to DTIMS-QTOF can be considered as promising tools for the quality control of oligonucleotides. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:10
相关论文
共 25 条
  • [1] Structure and Dynamics of Oligonucleotides in the Gas Phase
    Arcella, Annalisa
    Dreyer, Jens
    Ippoliti, Emiliano
    Ivani, Ivan
    Portella, Guillem
    Gabelica, Valerie
    Carloni, Paolo
    Orozco, Modesto
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2015, 54 (02) : 467 - 471
  • [2] Electronic Structures of LNA Phosphorothioate Oligonucleotides
    Bohr, Henrik G.
    Shim, Irene
    Stein, Cy
    Orum, Henrik
    Hansen, Henrik F.
    Koch, Troels
    [J]. MOLECULAR THERAPY-NUCLEIC ACIDS, 2017, 8 : 428 - 441
  • [3] Hydrophilic interaction liquid chromatography (HILIC)-a powerful separation technique
    Buszewski, Boguslaw
    Noga, Sylwia
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (01) : 231 - 247
  • [4] Determination of therapeutic oligonucleotides using capillary gel electrophoresis
    Chen, Buyun
    Bartlett, Michael G.
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (04) : 409 - 418
  • [5] Adding a new separation dimension to MS and LC-MS: What is the utility of ion mobility spectrometry?
    D'Atri, Valentina
    Causon, Tim
    Hernandez-Alba, Oscar
    Mutabazi, Aline
    Veuthey, Jean-Luc
    Cianferani, Sarah
    Guillarme, Davy
    [J]. JOURNAL OF SEPARATION SCIENCE, 2018, 41 (01) : 20 - 67
  • [6] Separation and identification of oligonucleotides by hydrophilic interaction liquid chromatography (HILIC)-inductively coupled plasma mass spectrometry (ICPMS)
    Easter, Renee N.
    Kroening, Karolin K.
    Caruso, Joseph A.
    Limbach, Patrick A.
    [J]. ANALYST, 2010, 135 (10) : 2560 - 2565
  • [7] PHOSPHOROTHIOATE ANALOGS OF NUCLEOTIDES
    ECKSTEIN, F
    [J]. ACCOUNTS OF CHEMICAL RESEARCH, 1979, 12 (06) : 204 - 210
  • [8] Application of pressure assisted electrokinetic injection technique in the measurements of DNA oligonucleotides and their adducts using capillary electrophoresis-mass spectrometry
    Feng, Yong-Lai
    Lian, Hongzhen
    Zhu, Jiping
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1148 (02) : 244 - 249
  • [9] Analysis of antisense oligonucleotides by capillary electrophoresis, gel-slab electrophoresis, and HPLC: A comparison
    Gelfi, C
    Perego, M
    Morelli, S
    Nicolin, A
    Righetti, PG
    [J]. ANTISENSE & NUCLEIC ACID DRUG DEVELOPMENT, 1996, 6 (01): : 47 - 53
  • [10] Analysis of oligonucleotides by hydrophilic interaction liquid chromatography coupled to negative ion electrospray ionization mass spectrometry
    Gong, Lingzhi
    McCullagh, James S. O.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (32) : 5480 - 5486