Salvage of Infected Cardiac Implantable Electrical Devices with Subpectoral Plane Pocket Revision

被引:0
|
作者
Chatterjee, Pallab [1 ]
Sharma, Anuj Kumar [2 ]
Pratap, Pranay [1 ]
Dabas, Ajay [3 ]
Mishra, Bharat [1 ]
Mehare, Samiksha [1 ]
机构
[1] Army Hosp R&R, Dept Plast & Reconstruct Surg, Delhi 110010, India
[2] Army Hosp R&R, Dept Surg, Delhi, India
[3] Command Hosp NC, Dept Surg, Udhampur, Jammu & Kashmir, India
关键词
CIED infection; CIED salvage; subpectoral CIED implantation; pectoralis major muscle; CARDIOVERTER-DEFIBRILLATOR; PERMANENT PACEMAKER; ELECTRONIC DEVICES; UNITED-STATES; MANAGEMENT; LEAD; COMPLICATIONS; DIAGNOSIS; GENERATOR; REMOVAL;
D O I
10.1055/s-0041-1735417
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction Infection of cardiac implantable electrical devices (CIEDs) may lead to serious complications. Complete CIED explantation is expensive, requires expertise, not free from complications, and may not be an option in patients with device dependence. Aim To highlight that carefully selected infected CIEDs can be salvaged by placing the device in a subpectoral pocket below the pectoralis major muscle. We conducted a retrospective descriptive observational study. Material and Methods Twelve patients (10 male and two female) with erosion, exposure or infection of infraclavicular, subcutaneously placed CIED were treated over a 30-month period between July 2018 and December 2020. The technique involved debridement and excision of a peridevice capsule, creating a subpectoral pocket beneath the pectoralis major muscle, and placing the CIED in a new pocket with total muscle coverage and closure of skin without tension. Results Twelve patients ( m = 10; f = 2) with a mean age of 65 years (range, 46-82 years) presented with infection of CIED within 9 months of implantation. None had sepsis or endocarditis. In nine patients, CIEDs were successfully salvaged with relocation to subpectoral pocket. Mean follow-up was 20 months (range, 8-30 months). Three out of 12 developed reinfection that ultimately required CIED explantation. There was no mortality. Conclusion In the absence of sepsis or endocarditis, infected CIEDs may be attempted at salvage by subpectoral pocket placement. This obviates the need for potentially risky explantation or replacement of expensive CIEDs.
引用
收藏
页码:344 / 349
页数:6
相关论文
共 50 条
  • [31] Infected cardiac-implantable electronic devices: prevention, diagnosis, and treatment
    Nielsen, Jens Cosedis
    Gerdes, Jens Christian
    Varma, Niraj
    EUROPEAN HEART JOURNAL, 2015, 36 (37) : 2484 - 2490
  • [32] THE ROLE OF TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN EXTRACTION OF INFECTED CARDIAC IMPLANTABLE ELECTROPHYSIOLOGICAL DEVICES
    Almahmoud, Mohamed Faher
    Fishbain, Joel
    Othman, Hussein
    Sabbagh, Salah
    Szpunar, Susan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (10) : A320 - A320
  • [33] Pocket infections of cardiac implantable electronic devices treated by negative pressure wound therapy
    McGarry, Thomas J.
    Joshi, Rajeev
    Kawata, Hiro
    Patel, Jigar
    Feld, Gregory
    Birgersdotter-Green, Ulrika M.
    Pretorius, Victor
    EUROPACE, 2014, 16 (03): : 372 - 377
  • [34] Outcomes of Lead Revision in Patients With Cardiac Perforation Associated With Cardiac Implantable Electronic Devices Placement
    Huang, Xinmiao
    Fu, Haixia
    Osborn, Michael
    Asirvatham, Samuel J.
    Sinak, Lawrence J.
    Friedman, Paul A.
    Cha, Yongmei
    CIRCULATION, 2013, 128 (22)
  • [35] Noninvasive Tissue Adhesive for Cardiac Implantable Electrical Device Pocket Closure: The TAPE Study
    Koerber, Scott M.
    Loethen, Troy
    Turagam, Mohit
    Cuoco, Frank
    Gautam, Sandeep
    CIRCULATION, 2017, 136
  • [36] A Novel Antibiotic Delivery Approach Enhances Salvage of Infected Cardiovascular-implantable Electronic Devices
    Topaz, Moris
    Kazatsker, Mark
    Ashkenazi, Itamar
    Schwartz, Arie L.
    Carmel-Neiderman, Narin N.
    Topaz, Guy
    Rosso, Raphael
    Glikson, Michael
    Viskin, Sami
    Shotan, Avraham
    CIRCULATION, 2020, 142
  • [37] Remote monitoring of cardiac implantable electrical devices in Europe: quo vadis?
    Boriani, Giuseppe
    EUROPACE, 2015, 17 (05): : 674 - 676
  • [38] Clinical utility of remote monitoring for patients with cardiac implantable electrical devices
    Yang, Shu
    Stabenau, Hans F.
    Kiernan, Katherine
    Diamond, Jamie E.
    Kramer, Daniel B.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (04) : 961 - 969
  • [39] Clinical utility of remote monitoring for patients with cardiac implantable electrical devices
    Shu Yang
    Hans F. Stabenau
    Katherine Kiernan
    Jamie E. Diamond
    Daniel B. Kramer
    Journal of Interventional Cardiac Electrophysiology, 2023, 66 : 961 - 969
  • [40] Cardiac Electrical Modeling for Closed-Loop Validation of Implantable Devices
    Ai, Weiwei
    Patel, Nitish D.
    Roop, Partha S.
    Malik, Avinash
    Trew, Mark L.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (02) : 536 - 544