Salvage of Infected Cardiac Implantable Electrical Devices with Subpectoral Plane Pocket Revision

被引:0
|
作者
Chatterjee, Pallab [1 ]
Sharma, Anuj Kumar [2 ]
Pratap, Pranay [1 ]
Dabas, Ajay [3 ]
Mishra, Bharat [1 ]
Mehare, Samiksha [1 ]
机构
[1] Army Hosp R&R, Dept Plast & Reconstruct Surg, Delhi 110010, India
[2] Army Hosp R&R, Dept Surg, Delhi, India
[3] Command Hosp NC, Dept Surg, Udhampur, Jammu & Kashmir, India
关键词
CIED infection; CIED salvage; subpectoral CIED implantation; pectoralis major muscle; CARDIOVERTER-DEFIBRILLATOR; PERMANENT PACEMAKER; ELECTRONIC DEVICES; UNITED-STATES; MANAGEMENT; LEAD; COMPLICATIONS; DIAGNOSIS; GENERATOR; REMOVAL;
D O I
10.1055/s-0041-1735417
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction Infection of cardiac implantable electrical devices (CIEDs) may lead to serious complications. Complete CIED explantation is expensive, requires expertise, not free from complications, and may not be an option in patients with device dependence. Aim To highlight that carefully selected infected CIEDs can be salvaged by placing the device in a subpectoral pocket below the pectoralis major muscle. We conducted a retrospective descriptive observational study. Material and Methods Twelve patients (10 male and two female) with erosion, exposure or infection of infraclavicular, subcutaneously placed CIED were treated over a 30-month period between July 2018 and December 2020. The technique involved debridement and excision of a peridevice capsule, creating a subpectoral pocket beneath the pectoralis major muscle, and placing the CIED in a new pocket with total muscle coverage and closure of skin without tension. Results Twelve patients ( m = 10; f = 2) with a mean age of 65 years (range, 46-82 years) presented with infection of CIED within 9 months of implantation. None had sepsis or endocarditis. In nine patients, CIEDs were successfully salvaged with relocation to subpectoral pocket. Mean follow-up was 20 months (range, 8-30 months). Three out of 12 developed reinfection that ultimately required CIED explantation. There was no mortality. Conclusion In the absence of sepsis or endocarditis, infected CIEDs may be attempted at salvage by subpectoral pocket placement. This obviates the need for potentially risky explantation or replacement of expensive CIEDs.
引用
收藏
页码:344 / 349
页数:6
相关论文
共 50 条
  • [21] Positive Pocket Cultures From Cardiac Implantable Electrophysiological Devices Without Infection
    Machino, Takeshi
    Sekiguchi, Yukio
    CIRCULATION JOURNAL, 2015, 79 (08) : 1680 - 1681
  • [22] Salvage of infected cardiac implantable electronic device with taurolidine-a case report
    Borov, Stefan
    Baldauf, Benito
    Lau, Ernest W.
    Bonnemeier, Hendrik
    CARDIOTHORACIC SURGEON, 2022, 30 (01):
  • [23] Pocket creation in the prepectoral subfascial position for the implantation of a cardiac implantable electrical device
    Imai, Katsuhiko
    JOURNAL OF ARRHYTHMIA, 2014, 30 (02) : 92 - 94
  • [24] The Role of Implantable Cardiac Electrical Devices in Patients with Myotonic Dystrophy
    Curtis, Anne B.
    Dalal, Kinan
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 (12) : 1376 - 1377
  • [25] Capacity of dental equipment to interfere with cardiac implantable electrical devices
    Lahor-Soler, Eduard
    Miranda-Rius, Jaume
    Brunet-Llobet, Lluis
    Sabate de la Cruz, Xavier
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2015, 123 (03) : 194 - 201
  • [26] Reproducibility of CMR in Patients With Cardiac Implantable Electrical Devices REPLY
    Ghonim, Sarah
    Babu-Narayan, Sonya V.
    JACC-CARDIOVASCULAR IMAGING, 2022, 15 (05) : 955 - 956
  • [27] Attempted salvage of infected cardiovascular implantable electronic devices: Are there clinical factors that predict success?
    Peacock, James E., Jr.
    Stafford, Jeanette M.
    Le, Katherine
    Sohail, Muhammad Rizwan
    Baddour, Larry M.
    Prutkin, Jordan M.
    Danik, Stephan B.
    Vikram, Holenarasipur R.
    Hernandez-Meneses, Marta
    Miro, Jose M.
    Blank, Elisabeth
    Naber, Christoph K.
    Carrillo, Roger G.
    Greenspon, Arnold J.
    Tseng, Chi-Hong
    Uslan, Daniel Z.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (05): : 524 - 531
  • [28] The Use of Electrocardiogram Smartwatches in Patients with Cardiac Implantable Electrical Devices
    Strik, Marc
    Ploux, Sylvain
    van der Zande, Joske
    Velraeds, Anouk
    Fontagne, Leslie
    Haissaguerre, Michel
    Bordachar, Pierre
    SENSORS, 2024, 24 (02)
  • [29] Single-photon cardiac imaging in patients with cardiac implantable electrical devices
    Cinzia Valzania
    Rachele Bonfiglioli
    Francesco Fallani
    Cristian Martignani
    Matteo Ziacchi
    Igor Diemberger
    Mauro Biffi
    Stefano Fanti
    Nazzareno Galiè
    Journal of Nuclear Cardiology, 2022, 29 : 633 - 641
  • [30] Single-photon cardiac imaging in patients with cardiac implantable electrical devices
    Valzania, Cinzia
    Bonfiglioli, Rachele
    Fallani, Francesco
    Martignani, Cristian
    Ziacchi, Matteo
    Diemberger, Igor
    Biffi, Mauro
    Fanti, Stefano
    Galie, Nazzareno
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (02) : 633 - 641