Measurement of respirable crystalline silica concentration by X-ray diffraction: Evaluation of metrological performances

被引:1
|
作者
Nebbia, Rebecca [1 ]
Genta, Gianfranco [1 ]
Zuliani, Paolo [2 ]
Patrucco, Mario [3 ]
Pira, Enrico [3 ]
Galetto, Maurizio [1 ]
机构
[1] Politecn Torino, Dept Management & Prod Engn, Corso Duca Abruzzi 24, I-10129 Turin, Italy
[2] AOU Citta Salute & Sci, Corso Bramante 88, I-10126 Turin, Italy
[3] Univ Torino, Dept Publ Hlth & Pediat, Turin, Italy
关键词
Respirable crystalline silica; X-ray diffraction; Measurement uncertainty; OS&H; Occupational safety; health; EXPOSURE; RISK;
D O I
10.1016/j.measurement.2021.109839
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Worker exposure to Respirable Crystalline Silica (RCS) is related with increased risk for lung cancer, so it is important to correctly assess it, through measurements of RCS. There are several methods for the uncertainty evaluation of the concentration of RCS measured by X-ray diffraction, however, none involves the calculation of the sensitivity coefficients of the mathematical measurement model. Hence, the aim of this research work is to propose an improved method, in which the sensitivity coefficients are calculated as partial derivatives of the model. The method was applied to four measurements campaigns in a factory, and the results seem to be comparable with those published in literature. It arose that for low concentrations the major contribution of uncertainty is due to the X-ray diffraction calibration line. This may mean that the minimum number of six calibration test filters, as suggested by the standards, is not sufficient, especially for low concentrations.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Applications of X-ray diffraction technique in the residual stress measurement of films
    School of Materials Science and Engineering, Southeast University, Nanjing 211189, China
    不详
    Gongneng Cailiao, 2007, 11 (1745-1749): : 1745 - 1749
  • [42] X-ray diffraction measurement of stresses in post-tensioning tendons
    Carfagno, MG
    Noorai, FS
    Brauss, ME
    Pineault, JA
    NONDESTRUCTIVE EVALUATION OF BRIDGES AND HIGHWAYS, 1996, 2946 : 51 - 56
  • [43] On the improvement of measurement accuracy of retained austenite in steel with X-ray diffraction
    Witte, M.
    Lesch, C.
    MATERIALS CHARACTERIZATION, 2018, 139 : 111 - 115
  • [44] Measurement of residual stresses in CFRP laminates by X-ray diffraction method
    C Balasingh
    Vandana Singh
    Bulletin of Materials Science, 1997, 20 : 325 - 332
  • [45] LATTICE MISFIT MEASUREMENT IN INCONEL 625 BY X-RAY DIFFRACTION TECHNIQUE
    Sarkar, A.
    Mukherjee, P.
    Barat, P.
    Jayakumar, T.
    Mahadevan, S.
    Rai, Sanjay K.
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2008, 22 (23): : 3977 - 3985
  • [46] Measurement of residual stresses in CFRP laminates by X-ray diffraction method
    Balasingh, C
    Singh, V
    BULLETIN OF MATERIALS SCIENCE, 1997, 20 (03) : 325 - 332
  • [47] Metrological characterization of X-ray diffraction methods for determination of crystallite size in nano-scale materials
    Uvarov, V.
    Popov, I.
    MATERIALS CHARACTERIZATION, 2007, 58 (10) : 883 - 891
  • [48] Development and metrological characterization of quantitative X-ray diffraction phase analysis for the mixtures of clopidogrel bisulphate polymorphs
    Uvarov, Vladimir
    Popov, Inna
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 46 (04) : 676 - 682
  • [49] Evaluation of workplace exposure to respirable crystalline silica in road construction industries in Alberta
    Couture, Ariel
    Elizabeth, Rose Marie Charuvil
    Lefsrud, Lianne
    Sattari, Fereshteh
    TOXICOLOGY AND INDUSTRIAL HEALTH, 2023, 39 (07) : 374 - 387
  • [50] Measurement Accuracy Analysis for Crystal Plane Spacing of Nitride Epitaxial Layer by X-ray diffraction
    Cui Jianjun
    Gao Sitian
    OPTICAL MEASUREMENT TECHNOLOGY AND INSTRUMENTATION, 2016, 10155