Multiview active appearance models for simultaneous segmentation of cardiac 2-and 4-chamber long-axis magnetic resonance images

被引:0
|
作者
Üzümcü, M
van der Geest, RJ
Sonka, M
Lamb, HJ
Reiber, JHC
Lelieveldt, BPF
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, NL-2333 ZA Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Div Image Proc, NL-2333 ZA Leiden, Netherlands
[3] Univ Iowa, Dept Elect & Comp Engn, Iowa City, IA 52242 USA
关键词
segmentation; image processing; active appearance models; model based;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Long-axis cardiac magnetic resonance (MR) views enable a rapid, online evaluation of cardiac function from only 2 views. In this article, we aimed to evaluate a model-based method for the simultaneous detection of 2- and 4-chamber endocardial and epicardial contours in end-diastolic and end-systolic phases of MR images. Methods: We introduce multiview Active Appearance Models for the automated segmentation of long-axis cardiac MR images of the left ventricle. Two modes of initialization were used to test the accuracy of the model with minimal user interaction and the best-obtainable accuracy with this model. The segmentation was initialized by annotating 2 points in the base and one in the apex. We tested the method's performance by comparing the point-to-curve errors, ejection fractions, and biplane area-length volumes calculated with the automatically detected contours to those calculated from contours that were annotated manually by experts. Leave-one-out experiments were performed with 2- and 4-chamber long axis MR images of 59 subjects in end-diastolic and end-systolic phases. Results: When initializing in all 4 frames, 97% of the segmentations were successful, and the standard deviation in the volume-errors with respect to the average manually identified volume was 9.0% for the end-diastolic volumes and 15% for the end-systolic volumes. When the method was initialized in the end-systolic frames only, 92% of the segmentations were successful, and the standard deviation in the errors in the volumes with respect to the average manually identified volume was 13.3% for the end-diastolic volumes and 16.7% for the end-systolic volumes. Bland-Altman plots showed that the errors were distributed randomly around 0, and by using a paired t test comparing manual and computer-determined volumes, we were able to detect that the volume differences were not significant. Simultaneous detection of the endocardial and epicardial contours in 2- and 4-chamber views and end-diastolic and end-systolic phases for one subject takes approximately 3 seconds. Conclusions: The accuracy of the reported method is comparable with the interobserver variability for initialization in all frames and slightly worse than the interobserver variability with initialization in the end-systolic frames only. However, in both cases the errors were not significant. Initialization in end-systolic frames only leads to a statistically insignificantly lower model accuracy; however, it requires only half the user interaction. Therefore, we can conclude that this method enables rapid analysis of the cardiac left ventricular function with little user interaction.
引用
收藏
页码:195 / 203
页数:9
相关论文
共 3 条
  • [1] AUTOMATIC SEGMENTATION OF CARDIAC MAGNETIC RESONANCE IMAGES USING ACTIVE APPEARANCE MODELS AND HAUSDORFF DISTANCE
    Ammar, Mohammed
    Mahmoudi, Said
    Chikh, Mohammed Amine
    Abbou, Amine
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2012, 12 (04)
  • [2] Cardiac magnetic resonance analysis of right ventricular function: comparison of quantification in the short-axis and 4-chamber planes
    Souto Bayarri, M.
    Masip Capdevil, L.
    Remuinan Pereira, C.
    Suarez-Cuenca, J. J.
    Martinez Monzonis, A.
    Couto Perez, M. I.
    Carreira Villamor, J. M.
    RADIOLOGIA, 2015, 57 (01): : 50 - 55
  • [3] Multi-view active appearance models for consistent segmentation of multiple standard views:: application to long- and short-axis cardiac MR images
    Lelieveldt, BPF
    Üzümcü, M
    van der Geest, RJ
    Reiber, JHC
    Sonka, M
    CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 1141 - 1146