In silico study of vessel and stent-graft parameters on the potential success of endovascular aneurysm repair

被引:16
作者
Hemmler, Andre [1 ]
Lutz, Brigitta [2 ]
Reeps, Christian [2 ]
Gee, Michael W. [1 ]
机构
[1] Tech Univ Munich, Mech & High Performance Comp Grp, Parkring 35, D-85748 Garching, Germany
[2] Univ Klinikum Carl Gustav Carus Dresden, Klin Viszeral Thorax & Gefasschirurg, Fetscherstr 74, D-01307 Dresden, Germany
关键词
abdominal aortic aneurysm; endovascular repair; hostile neck; oversizing; stent-graft; ABDOMINAL-AORTIC-ANEURYSM; WALL STRESS-ANALYSIS; BIOMECHANICAL PROBLEMS; NUMERICAL-SIMULATION; CLINICAL-OUTCOMES; PROXIMAL FIXATION; NECK DILATATION; MIGRATION; MODEL; HOSTILE;
D O I
10.1002/cnm.3237
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The variety of stent-graft (SG) design variables (eg, SG type and degree of SG oversizing) and the complexity of decision making whether a patient is suitable for endovascular aneurysm repair (EVAR) raise the need for the development of predictive tools to assist clinicians in the preinterventional planning phase. Recently, some in silico EVAR methods have been developed to predict the deployed SG configuration. However, only few studies investigated how to assess the in silico EVAR outcome with respect to EVAR complication likelihoods (eg, endoleaks and SG migration). Based on a large literature study, in this contribution, 20 mechanical and geometrical parameters (eg, SG drag force and SG fixation force) are defined to evaluate the quality of the in silico EVAR outcome. For a cohort of n = 146 realizations of parameterized vessel and SG geometries, the in silico EVAR results are studied with respect to these mechanical and geometrical parameters. All degrees of SG oversizing in the range between 5% and 40% are investigated continuously by a computationally efficient parameter continuation approach. The in silico investigations have shown that the mechanical and geometrical parameters are able to indicate candidates at high risk of postinterventional complications. Hence, this study provides the basis for the development of a simulation-based metric to assess the potential success of EVAR based on engineering parameters.
引用
收藏
页数:37
相关论文
共 50 条
  • [41] Internal iliac artery occlusion using a stent-graft tunnel during endovascular aneurysm repair: A new alternative to coil embolization
    Rajasinghe, HA
    Pigott, JP
    Kritpracha, B
    Corbey, MJ
    Beebe, HG
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2003, 10 (06) : 1082 - 1086
  • [42] Sex different abdominal artery anatomy may induce different displacement force on stent-graft after endovascular aneurysm repair
    Teng, Anna
    Sun, Anqiang
    Chen, Zengsheng
    Deng, Xiaoyan
    Fan, Yubo
    [J]. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2023, 39 (10)
  • [43] Pseudoendoleak - Residual intrasaccular contrast after endovascular stent-graft repair
    Lee, WA
    Rubin, GD
    Johnson, BL
    Arko, F
    Fogarty, TJ
    Zarins, CK
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2002, 9 (01) : 119 - 123
  • [44] Development of a branched stent-graft for endovascular repair of aortic arch aneurysms
    Chuter, TAM
    Buck, DG
    Schneider, DB
    Reilly, LM
    Messina, LM
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2003, 10 (05) : 940 - 945
  • [45] Type A dissection following endovascular thoracic aortic stent-graft repair
    Neuhauser, B
    Czermak, BV
    Fish, J
    Perkmann, R
    Jaschke, W
    Chemelli, A
    Fraedrich, G
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2005, 12 (01) : 74 - 81
  • [46] Emergency endovascular stent-graft repair of a traumatic ruptured renal artery aneurysm: A case report
    Elbaroni, Wesam
    Lepiarczyk, Oskar
    McAdam, Andrew
    Connolly, David
    Kennedy, Peter
    [J]. UROLOGY CASE REPORTS, 2021, 38
  • [47] Intraoperative rupture of an abdominal aortic aneurysm during an endovascular stent-graft procedure
    David M. Moskowitz
    Ronald A. Kahn
    Michael L. Marin
    Larry H. Hollier
    [J]. Canadian Journal of Anesthesia, 1999, 46 : 887 - 890
  • [48] A Systematic Review and Meta-analysis of Endovascular Popliteal Aneurysm Repair Using the Hemobahn/Viabahn Stent-Graft
    Patel, Shaneel R.
    Hughes, Cian O.
    Jones, Keith G.
    Holt, Peter J. E.
    Thompson, Matt M.
    Hinchliffe, Robert J.
    Karthikesalingam, Alan
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2015, 22 (03) : 330 - 337
  • [49] Re: Aortoiliac aneurysm with arteriocaval fistula treated by a bifurcated endovascular stent-graft
    Richard W. J. Hartley
    Carolyn J. Beveridge
    John D. G. Rose
    Henry C. C. Pleass
    John Chamberlain
    Michael G. Wyatt
    [J]. CardioVascular and Interventional Radiology, 1999, 22 : 439 - 439
  • [50] Intraoperative rupture of an abdominal aortic aneurysm during an endovascular stent-graft procedure
    Moskowitz, DM
    Kahn, RA
    Marin, ML
    Hollier, LH
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1999, 46 (09): : 887 - 890