In silico study of vessel and stent-graft parameters on the potential success of endovascular aneurysm repair

被引:16
作者
Hemmler, Andre [1 ]
Lutz, Brigitta [2 ]
Reeps, Christian [2 ]
Gee, Michael W. [1 ]
机构
[1] Tech Univ Munich, Mech & High Performance Comp Grp, Parkring 35, D-85748 Garching, Germany
[2] Univ Klinikum Carl Gustav Carus Dresden, Klin Viszeral Thorax & Gefasschirurg, Fetscherstr 74, D-01307 Dresden, Germany
关键词
abdominal aortic aneurysm; endovascular repair; hostile neck; oversizing; stent-graft; ABDOMINAL-AORTIC-ANEURYSM; WALL STRESS-ANALYSIS; BIOMECHANICAL PROBLEMS; NUMERICAL-SIMULATION; CLINICAL-OUTCOMES; PROXIMAL FIXATION; NECK DILATATION; MIGRATION; MODEL; HOSTILE;
D O I
10.1002/cnm.3237
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The variety of stent-graft (SG) design variables (eg, SG type and degree of SG oversizing) and the complexity of decision making whether a patient is suitable for endovascular aneurysm repair (EVAR) raise the need for the development of predictive tools to assist clinicians in the preinterventional planning phase. Recently, some in silico EVAR methods have been developed to predict the deployed SG configuration. However, only few studies investigated how to assess the in silico EVAR outcome with respect to EVAR complication likelihoods (eg, endoleaks and SG migration). Based on a large literature study, in this contribution, 20 mechanical and geometrical parameters (eg, SG drag force and SG fixation force) are defined to evaluate the quality of the in silico EVAR outcome. For a cohort of n = 146 realizations of parameterized vessel and SG geometries, the in silico EVAR results are studied with respect to these mechanical and geometrical parameters. All degrees of SG oversizing in the range between 5% and 40% are investigated continuously by a computationally efficient parameter continuation approach. The in silico investigations have shown that the mechanical and geometrical parameters are able to indicate candidates at high risk of postinterventional complications. Hence, this study provides the basis for the development of a simulation-based metric to assess the potential success of EVAR based on engineering parameters.
引用
收藏
页数:37
相关论文
共 50 条
  • [31] Absence of buttock claudication following stent-graft coverage of the hypogastric artery without coil embolization in endovascular aneurysm repair
    Mell, Matthew
    Tefera, Girma
    Schwarze, Margaret
    Carr, Sandra
    Acher, Charles
    Hoch, John
    Turnipseed, William
    JOURNAL OF ENDOVASCULAR THERAPY, 2006, 13 (03) : 415 - 419
  • [32] Ventana Fenestrated Stent-Graft System for Endovascular Repair of Juxtarenal Aortic Aneurysms
    Mertens, Renato
    Bergoeing, Michel
    Marine, Leopoldo
    Valdes, Francisco
    Kraemer, Albrecht
    Vergara, Jeanette
    JOURNAL OF ENDOVASCULAR THERAPY, 2012, 19 (02) : 173 - 178
  • [33] Efficacy of Unibody Bifurcated Endovascular Stent-Graft Repair in the Treatment of Abdominal Aortic Aneurysm
    Shi, Chaohai
    Chen, Quan
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2019, 29 (05): : 444 - 447
  • [34] Influence of Different Self-Expanding Stent-Graft Types on Remodeling of the Aortic Neck After Endovascular Aneurysm Repair
    Oberhuber, Alexander
    Schwarz, Alexander
    Hoffmann, Martin H.
    Klass, Oliver
    Orend, Karl-Heinz
    Muehling, Bernd
    JOURNAL OF ENDOVASCULAR THERAPY, 2010, 17 (06) : 677 - 684
  • [35] Endovascular Stent-Graft Repair of Major Abdominal Arteriovenous Fistula: A Systematic Review
    Antoniou, George A.
    Koutsias, Stylianos
    Karathanos, Christos
    Sfyroeras, Giorgos S.
    Vretzakis, Georgios
    Giannoukas, Athanasios D.
    JOURNAL OF ENDOVASCULAR THERAPY, 2009, 16 (04) : 514 - 523
  • [36] A standardized aortic aneurysm model for the assessment of endovascular stent-graft technology
    Macierewicz, J. A.
    Albertini, J-N
    Hinchliffe, R. J.
    VASCULAR, 2011, 19 (02) : 82 - 88
  • [37] Thoracic CT findings following endovascular stent-graft treatment for thoracic aortic aneurysm
    Ishida, Masaki
    Kato, Noriyuki
    Hirano, Tadanori
    Shimono, Takatsugu
    Shimpo, Hideto
    Takeda, Kan
    JOURNAL OF ENDOVASCULAR THERAPY, 2007, 14 (03) : 333 - 341
  • [38] Midterm Results of Endovascular Aneurysm Repair Using the Endurant Stent-Graft According to the Instructions for Use vs. Off-Label Conditions
    Troisi, Nicola
    Torsello, Giovanni
    Weiss, Kristin
    Donas, Konstantinos P.
    Michelagnoli, Stefano
    Austermann, Martin
    JOURNAL OF ENDOVASCULAR THERAPY, 2014, 21 (06) : 841 - 847
  • [39] Re: Ureteroarterial Fistula: Endovascular Repair with a Stent-Graft
    Noriyuki Kato
    Tatsuya Kawaguchi
    Tomoaki Kondo
    Yoshihiro Hasegawa
    Masaki Ishida
    Hajime Sakuma
    Juichi Kawamura
    Isao Yada
    Kan Takeda
    CardioVascular and Interventional Radiology, 2002, 25 : 158 - 159
  • [40] A temporary hemostatic valve in the short limb of a bifurcated stent-graft to facilitate endovascular repair of ruptured aortic aneurysm: Experimental findings
    Jongkind, V
    Diks, J
    Linsen, MAM
    Vos, AWF
    Rauwerda, JA
    Wisselink, W
    JOURNAL OF ENDOVASCULAR THERAPY, 2005, 12 (01) : 66 - 69