In silico study of vessel and stent-graft parameters on the potential success of endovascular aneurysm repair

被引:16
作者
Hemmler, Andre [1 ]
Lutz, Brigitta [2 ]
Reeps, Christian [2 ]
Gee, Michael W. [1 ]
机构
[1] Tech Univ Munich, Mech & High Performance Comp Grp, Parkring 35, D-85748 Garching, Germany
[2] Univ Klinikum Carl Gustav Carus Dresden, Klin Viszeral Thorax & Gefasschirurg, Fetscherstr 74, D-01307 Dresden, Germany
关键词
abdominal aortic aneurysm; endovascular repair; hostile neck; oversizing; stent-graft; ABDOMINAL-AORTIC-ANEURYSM; WALL STRESS-ANALYSIS; BIOMECHANICAL PROBLEMS; NUMERICAL-SIMULATION; CLINICAL-OUTCOMES; PROXIMAL FIXATION; NECK DILATATION; MIGRATION; MODEL; HOSTILE;
D O I
10.1002/cnm.3237
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The variety of stent-graft (SG) design variables (eg, SG type and degree of SG oversizing) and the complexity of decision making whether a patient is suitable for endovascular aneurysm repair (EVAR) raise the need for the development of predictive tools to assist clinicians in the preinterventional planning phase. Recently, some in silico EVAR methods have been developed to predict the deployed SG configuration. However, only few studies investigated how to assess the in silico EVAR outcome with respect to EVAR complication likelihoods (eg, endoleaks and SG migration). Based on a large literature study, in this contribution, 20 mechanical and geometrical parameters (eg, SG drag force and SG fixation force) are defined to evaluate the quality of the in silico EVAR outcome. For a cohort of n = 146 realizations of parameterized vessel and SG geometries, the in silico EVAR results are studied with respect to these mechanical and geometrical parameters. All degrees of SG oversizing in the range between 5% and 40% are investigated continuously by a computationally efficient parameter continuation approach. The in silico investigations have shown that the mechanical and geometrical parameters are able to indicate candidates at high risk of postinterventional complications. Hence, this study provides the basis for the development of a simulation-based metric to assess the potential success of EVAR based on engineering parameters.
引用
收藏
页数:37
相关论文
共 99 条
[81]   Predictors of Abdominal Aortic Aneurysm Sac Enlargement After Endovascular Repair [J].
Schanzer, Andres ;
Greenberg, Roy K. ;
Hevelone, Nathanael ;
Robinson, William P. ;
Eslami, Mohammad H. ;
Goldberg, Robert J. ;
Messina, Louis .
CIRCULATION, 2011, 123 (24) :2848-2855
[82]   Serious complications that require surgical interventions after endoluminal stent-graft placement for the treatment of infrarenal aortic aneurysms [J].
Schlensak, C ;
Doenst, T ;
Hauer, M ;
Bitu-Moreno, J ;
Uhrmeister, P ;
Spillner, G ;
Beyersdorf, F .
JOURNAL OF VASCULAR SURGERY, 2001, 34 (02) :198-203
[83]   Validation of a New Methodology to Determine 3-Dimensional Endograft Apposition, Position, and Expansion in the Aortic Neck After Endovascular Aneurysm Repair [J].
Schuurmann, Richte C. L. ;
Overeem, Simon P. ;
van Noort, Kim ;
de Vries, Bastiaan A. ;
Slump, Cornelis H. ;
de Vries, Jean-Paul P. M. .
JOURNAL OF ENDOVASCULAR THERAPY, 2018, 25 (03) :358-365
[84]   Sizing Considerations for GORE Excluder in Angulated Aortic Aneurysm Necks [J].
Shiraev, Timothy ;
Agostinho, Nelson ;
Dubenec, Steven .
ANNALS OF VASCULAR SURGERY, 2018, 49 :152-157
[85]   Prosthetic replacement of the aorta is a risk factor for aortic root aneurysm development [J].
Simon-Kupilik, N ;
Schima, H ;
Huber, L ;
Moidl, R ;
Wipplinger, G ;
Losert, U ;
Wolner, E ;
Simon, P .
ANNALS OF THORACIC SURGERY, 2002, 73 (02) :455-459
[86]  
Singh C, 2017, AIMS BIOENG, V4, P133, DOI 10.3934/bioeng.2017.1.133
[87]   Patient-Specific AAA Wall Stress Analysis: 99-Percentile Versus Peak Stress [J].
Speelman, L. ;
Bosboom, E. M. H. ;
Schurink, G. W. H. ;
Hellenthal, F. A. M. V. I. ;
Buth, J. ;
Breeuwer, M. ;
Jacobs, M. J. ;
van de Vosse, F. N. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2008, 36 (06) :668-676
[88]   A computational assessment of the hemodynamic effects of crossed and non-crossed bifurcated stent-graft devices for the treatment of abdominal aortic aneurysms [J].
Stefanov, Florian ;
McGloughlin, Tim ;
Morris, Liam .
MEDICAL ENGINEERING & PHYSICS, 2016, 38 (12) :1458-1473
[89]   Influence of endograft oversizing on device migration, endoleak, aneurysm shrinkage, and aortic neck dilation: Results from the Zenith multicenter trial [J].
Sternbergh, WC ;
Money, SR ;
Greenberg, RK ;
Chuter, TAM .
JOURNAL OF VASCULAR SURGERY, 2004, 39 (01) :20-26
[90]   Increased Pulse Wave Velocity and Arterial Hypertension in Young Patients With Thoracic Aortic Endografts [J].
Tzilalis, Vasileios D. ;
Kamvysis, Dimitrios ;
Panagou, Panagiotis ;
Kaskarelis, Ioannis ;
Lazarides, Miltos K. ;
Perdikides, Theodossios ;
Prassopoulos, Panagiotis ;
Boudoulas, Harisios .
ANNALS OF VASCULAR SURGERY, 2012, 26 (04) :462-467