摘要
The variety of stent-graft (SG) design variables (eg, SG type and degree of SG oversizing) and the complexity of decision making whether a patient is suitable for endovascular aneurysm repair (EVAR) raise the need for the development of predictive tools to assist clinicians in the preinterventional planning phase. Recently, some in silico EVAR methods have been developed to predict the deployed SG configuration. However, only few studies investigated how to assess the in silico EVAR outcome with respect to EVAR complication likelihoods (eg, endoleaks and SG migration). Based on a large literature study, in this contribution, 20 mechanical and geometrical parameters (eg, SG drag force and SG fixation force) are defined to evaluate the quality of the in silico EVAR outcome. For a cohort of n = 146 realizations of parameterized vessel and SG geometries, the in silico EVAR results are studied with respect to these mechanical and geometrical parameters. All degrees of SG oversizing in the range between 5% and 40% are investigated continuously by a computationally efficient parameter continuation approach. The in silico investigations have shown that the mechanical and geometrical parameters are able to indicate candidates at high risk of postinterventional complications. Hence, this study provides the basis for the development of a simulation-based metric to assess the potential success of EVAR based on engineering parameters.
引用
收藏
页数:37
相关论文
共 50 条
  • [1] Outcomes of Endovascular Aneurysm Repair Using the Anaconda Stent-Graft
    Tigkiropoulos, Konstantinos
    Stavridis, Kyriakos
    Lazaridis, Ioannis
    Bontinis, Evangelos
    Zournatzi, Ioulia
    Kolaki, Nikoletta
    Karamanos, Dimitrios
    Saratzis, Nikolaos
    JOURNAL OF ENDOVASCULAR THERAPY, 2020, 27 (03) : 462 - 467
  • [2] Evolution of the Proximal Sealing Rings of the Anaconda Stent-Graft After Endovascular Aneurysm Repair
    Koenrades, Maaike A.
    Klein, Almar
    Leferink, Anne M.
    Slump, Cornelis H.
    Geelkerken, Robert H.
    JOURNAL OF ENDOVASCULAR THERAPY, 2018, 25 (04) : 480 - 491
  • [3] Immediate Change in Suprarenal Neck Angulation After Endovascular Aneurysm Repair: Comparison of the Ovation Stent-Graft Inflatable Sealing Rings to a Conventional Self-Expanding Stent-Graft
    Georgakarakos, Efstratios
    Ioannou, Christos V.
    Trellopoulos, George
    Kontopodis, Nikolaos
    Papachristodoulou, Athanasia
    Torsello, Giovanni
    Bisdas, Theodosios
    JOURNAL OF ENDOVASCULAR THERAPY, 2015, 22 (04) : 613 - 619
  • [4] Stent-graft surface movement after endovascular aneurysm repair: baseline parameters for prediction, and association with migration and stent-graft-related endoleaks
    Asenbaum, Ulrika
    Schoder, Maria
    Schwartz, Ernst
    Langs, Georg
    Baltzer, Pascal
    Wolf, Florian
    Prusa, Alexander M.
    Loewe, Christian
    Nolz, Richard
    EUROPEAN RADIOLOGY, 2019, 29 (12) : 6385 - 6395
  • [5] Factors and forces influencing stent-graft migration after endovascular aortic aneurysm repair
    Mohan, IV
    Harris, PL
    van Marrewijk, CJ
    Laheij, RJ
    How, TV
    JOURNAL OF ENDOVASCULAR THERAPY, 2002, 9 (06) : 748 - 755
  • [6] Endovascular stent-graft prosthesis of aortic aneurysm
    Ince, H
    Nienaber, CA
    ZEITSCHRIFT FUR KARDIOLOGIE, 2001, 90 (01): : 67 - 72
  • [7] Endovascular Repair of a Thoracic Arch Aneurysm With a Fenestrated Stent-Graft
    Yuan, Liangxi
    Feng, Xiang
    Jing, Zaiping
    JOURNAL OF ENDOVASCULAR THERAPY, 2008, 15 (05) : 539 - 543
  • [8] Adjunctive Iliac Stents Reduce the Risk of Stent-Graft Limb Occlusion Following Endovascular Aneurysm Repair With the Zenith Stent-Graft
    Oshin, Olufemi A.
    Fisher, Robert K.
    Williams, Leith A.
    Brennan, John A.
    Gilling-Smith, Geoffrey L.
    Vallabhaneni, S. Rao
    McWilliams, Richard G.
    JOURNAL OF ENDOVASCULAR THERAPY, 2010, 17 (01) : 108 - 114
  • [9] Iliac conduit for renal and visceral artery access during endovascular repair of a pararenal aneurysm with a fenestrated stent-graft
    Batt, Michel
    Haulon, Stephan
    Bouillanne, Pierre-Jean
    Baque, Jean
    Fassbender, Verena
    Haudebourg, Pierre
    Hassen-Khodja, Reda
    Jean-Baptiste, Elixene
    JOURNAL OF ENDOVASCULAR THERAPY, 2007, 14 (03) : 416 - 420
  • [10] Frequency, predictive factors, and consequences of stent-graft kink following endovascular AAA repair
    Fransen, GAJ
    Desgranges, P
    Laheij, RJF
    Harris, PL
    Becquemin, JP
    JOURNAL OF ENDOVASCULAR THERAPY, 2003, 10 (05) : 913 - 918