Voltammetric detection of the DNA interaction with copper complex compounds and damage to DNA

被引:1
|
作者
Labuda, J [1 ]
Bucková, M
Vanícková, M
Mattusch, J
Wennrich, R
机构
[1] Slovak Univ Technol Bratislava, Dept Analyt Chem, Bratislava 81237, Slovakia
[2] UFZ Helmholtz Ctr Environm Res, Environm Res Ctr, D-04318 Leipzig, Germany
关键词
copper complex; calf thymus DNA; DNA modified electrode; biosensor; chemical nuclease; damage to DNA;
D O I
10.1002/(SICI)1521-4109(199902)11:2<101::AID-ELAN101>3.0.CO;2-V
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Binding reactions of copper(II) complexes of 1,10-phenanthroline (phen) and tetraaza macrocyclic ligand TAAB with calf thymus DNA have been investigated voltammetrically at bare and DNA modified glassy carbon electrodes. The values of binding constant, binding site size, ratio of binding constants for the reduced and oxidized copper complex forms as well as information on the electrostatic and intercalative binding modes were obtained by solution and surface-based methods. The Cu(phen)S' complex mediates the dsDNA cleavage to a higher degree than Cu(TAAB)(2+) as indicated by the redox marker Co(phen)(3)(3+) and the anodic signal of the DNA base. A procedure for the damage to DNA detection using dsDNA/GCE biosensor is proposed.
引用
收藏
页码:101 / 107
页数:7
相关论文
共 50 条
  • [41] INTERACTION OF THE QUINOBENOXAZINE COMPOUNDS WITH DNA
    SUN, D
    FAN, JY
    HURLEY, LH
    CLEMENT, J
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 206 : 115 - MEDI
  • [42] DNA INTERACTION STUDIES BY UV OF COPPER COMPLEX BASED ON HETEROCYCLIC CHALCONES
    Maste, M. M.
    Hegde, V
    Desai, S. Mutalik
    Saxena, A.
    Inamdar, P.
    Debnath, P.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2020, 11 (12): : 6232 - 6236
  • [43] Hydrothermal Synthesis and DNA Interaction Studies of Copper(II)L Complex
    Cao, Yuan-Ying
    Xia, Hong
    Wang, Lin
    ASIAN JOURNAL OF CHEMISTRY, 2011, 23 (11) : 5177 - 5178
  • [44] Erratum to: Voltammetric DNA Sensors for the DNA Damage Detection Using Poly (Acridine Orange) Coatings Deposited from Reline and Glyceline
    A. V. Porfireva
    Z. F. Khusnutdinova
    G. A. Evtyugin
    Journal of Analytical Chemistry, 2025, 80 (1) : 201 - 201
  • [45] Antioxidant and prooxidant effects of polyphenol compounds on copper-mediated DNA damage
    Perron, Nathan R.
    Garcia, Carla R.
    Pinzon, Julio R.
    Chaur, Manuel N.
    Brumaghim, Julia L.
    JOURNAL OF INORGANIC BIOCHEMISTRY, 2011, 105 (05) : 745 - 753
  • [46] Polyelectrolyte Polyethylenimine-DNA Complexes in the Composition of Voltammetric Sensors for Detecting DNA Damage
    Malanina, A. N.
    Kuzin, Yu, I
    Ivanov, A. N.
    Ziyatdinova, G. K.
    Shurpik, D. N.
    Stoikov, I. I.
    Evtugyn, G. A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 77 (02) : 185 - 194
  • [47] Study on the Interaction of Amoxicillin and DNA by Spectroscopic and Voltammetric Studies
    Hajian, R.
    Shams, N.
    Azarinezhad, N.
    ASIAN JOURNAL OF CHEMISTRY, 2010, 22 (10) : 8007 - 8016
  • [48] Voltammetric studies of the interaction of nogalamycin antitumor drug with DNA
    Ibrahim, MS
    ANALYTICA CHIMICA ACTA, 2001, 443 (01) : 63 - 72
  • [49] A square wave voltammetric study of the interaction of procaine with DNA
    Aslanoglu, M
    ACTA CHIMICA SLOVENICA, 2004, 51 (01) : 107 - 116
  • [50] DNA damage drives detection
    Kirsty Minton
    Nature Reviews Immunology, 2013, 13 : 704 - 705