The effect of respiratory motion on forward intensity modulated radiotherapy for breast cancer

被引:3
作者
Song, Taesoo [1 ]
Suh, Chang-Ok [1 ]
Lee, Ikjae [1 ]
Jeong, Kyoungkeun [1 ]
Keum, Kichang [1 ]
Lee, Chang Geol [1 ]
Seong, Jinsil [1 ]
Cho, Jae Ho [1 ]
机构
[1] Yonsei Univ, Coll Med, Yonsei Canc Ctr, Dept Radiat Oncol, Seoul, South Korea
关键词
breast cancer; forward IMRT; field-in-field technique; blurred dose distribution;
D O I
10.1177/153303460800700306
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This study evaluated the effect of respiratory movement on field-in-field (FIF) forward intensity-modulated radiotherapy (IMRT) for the treatment of breast cancer. FIF forward IMRT was performed on ten patients receiving radiotherapy to the whole breast after conservation surgery. Assuming that breast motion follows a sophisticated cyclic function, the changes in hot and cold region, dose homogeneity index (DHI), and skin dose were examined at different respiration amplitudes of 1 cm, 2 cm, and 3 cm. FIF forward IMRT significantly improved the hot region, DHI, and skin dose, but slightly worsened the cold region, compared to the two wedged tangential technique (TWT). Interestingly, we found that the respiration amplitude affected the DHI and cold region but had no effect on the hot region and skin dose. The DHI was slightly improved at 1 cm of amplitude probably due to the blurring effect, remained unchanged at 2 cm of amplitude, and was worsened at 3 cm of amplitude. FIF forward IMRT significantly increased the cold region at 2 cm and 3 cm of respiration amplitude compared to the TWT. At 3 cm of respiration amplitude, an average cold region of 3.27 cm(3) was observed. In summary, our data indicate that during FIF forward IMRT, respiration movement has an important effect on various endpoints depending on the respiration amplitude of the patient.
引用
收藏
页码:207 / 215
页数:9
相关论文
共 29 条
[1]   Dosimetric improvements following 3D planning of tangential breast irradiation [J].
Aref, A ;
Thornton, D ;
Youssef, E ;
He, T ;
Tekyi-Mensah, S ;
Denton, L ;
Ezzell, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (05) :1569-1574
[2]  
BEADLE GF, 1984, CANCER, V54, P2911, DOI 10.1002/1097-0142(19841215)54:12<2911::AID-CNCR2820541216>3.0.CO
[3]  
2-V
[4]  
Bohmer D, 1998, STRAHLENTHER ONKOL, V174, P36
[5]   Dosimetric analysis of intact breast irradiation in off-axis planes [J].
Buchholz, TA ;
Gurgoze, E ;
Bice, WS ;
Prestidge, BR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (01) :261-267
[6]  
Chavaudra J, 2001, Cancer Radiother, V5, P472, DOI 10.1016/S1278-3218(01)00117-2
[7]   Breast movement during normal and deep breathing, respiratory training and set up errors: implications for external beam partial breast irradiation [J].
Chopra, S. ;
Dinshaw, K. A. ;
Kamble, R. ;
Sarin, R. .
BRITISH JOURNAL OF RADIOLOGY, 2006, 79 (945) :766-773
[8]   The effects of intra-fraction organ motion on the delivery of intensity-modulated field with a multileaf collimator [J].
Chui, CS ;
Yorke, E ;
Hong, L .
MEDICAL PHYSICS, 2003, 30 (07) :1736-1746
[9]   The effect of respiratory cycle and radiation beam-on timing on the dose distribution of free-breathing breast treatment using dynamic IMRT [J].
Ding, Chuxiong ;
Li, Xiang ;
Huq, M. Saitul ;
Saw, Cheng B. ;
Heron, Dwight E. ;
Yue, Ning J. .
MEDICAL PHYSICS, 2007, 34 (09) :3500-3509
[10]   Surface and build-up region dosimetry for obliquely incident intensity modulated radiotherapy 6 MV x rays [J].
Dogan, N ;
Glasgow, GP .
MEDICAL PHYSICS, 2003, 30 (12) :3091-3096