Numerical investigation of air cooling system for a densely packed battery to enhance the cooling performance through cell arrangement strategy

被引:16
|
作者
Saechan, Patcharin [1 ]
Dhuchakallaya, Isares [2 ]
机构
[1] King Mongkuts Univ Technol North Bangkok, Fac Engn, Bangkok, Thailand
[2] Thammasat Univ, Fac Engn, Thammasat Sch Engn, Klongluang 12120, Pathumthani, Thailand
关键词
air-cooled; battery arrangement; cooling performance; cylindrical battery; densely packed battery; thermal management; THERMAL MANAGEMENT-SYSTEM; PHASE-CHANGE MATERIALS; LITHIUM-ION BATTERIES; HEAT-PIPE; MODEL;
D O I
10.1002/er.7571
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Recent studies have revealed that the operating temperature and temperature uniformity within the battery pack significantly affected its performance. In this study, the air-cooled thermal management system of a densely packed battery pack was numerically investigated under different cell arrangements such as inline, offset, and staggered configurations to evaluate their cooling characteristics. The effects of inlet ambient air velocity and discharge rate were also evaluated to guarantee the temperature of the battery pack operated within an optimal range. The results revealed that increased airflow enhanced the cooling performance of the system but also increased the flow resistance, resulting in large power consumption. A battery pack operating at the low discharge rate of 0.5C might not require forced air-cooling. For fast discharge rates, especially over 2C-rate, forced air-cooling would not be economical for battery thermal management. A narrow cell-to-cell distance can decrease the cell temperature and also improve space utilization; however, it increased the power consumption for circulating air and the risk of a thermal runaway propagation. A trade-off between thermal dissipation and energy consumption was investigated. After comparing several circumstances, the offset layout was the appropriate choice for the air-cooled thermal management system, followed by the inline layout. It satisfied the requirements of low power consumption, high space utilization, and efficient cooling performance; in particular, the offset layout consumed about 43.1% less power than the inline layout, while losing space utilization of only 6.3%.
引用
收藏
页码:20670 / 20684
页数:15
相关论文
共 50 条
  • [1] Thermal Management of Densely-packed EV Battery With Forced Air Cooling Strategies
    Lu, Z.
    Meng, X. Z.
    Wei, L. C.
    Hu, W. Y.
    Zhang, L. Y.
    Jin, L. W.
    CUE 2015 - APPLIED ENERGY SYMPOSIUM AND SUMMIT 2015: LOW CARBON CITIES AND URBAN ENERGY SYSTEMS, 2016, 88 : 682 - 688
  • [2] Experimental investigation on reciprocating air-cooling strategy of battery thermal management system
    Wang, Chun
    Xu, Jun
    Wang, Meiwei
    Xi, Huan
    JOURNAL OF ENERGY STORAGE, 2023, 58
  • [3] Numerical investigation on cooling performance of PCM/cooling plate hybrid system for power battery with variable discharging conditions
    Ding, Bin
    Qi, Zeng-Hui
    Mao, Cong-Shan
    Gong, Liang
    Liu, Xiang-Lei
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2020, 141 (01) : 625 - 633
  • [4] Numerical investigation on cooling performance of PCM/cooling plate hybrid system for power battery with variable discharging conditions
    Bin Ding
    Zeng-Hui Qi
    Cong-Shan Mao
    Liang Gong
    Xiang-Lei Liu
    Journal of Thermal Analysis and Calorimetry, 2020, 141 : 625 - 633
  • [5] Numerical simulation and experimental investigation of air cooling system using thermoelectric cooling system
    A. Fattahpour Moazzez
    G. Najafi
    B. Ghobadian
    S. S. Hoseini
    Journal of Thermal Analysis and Calorimetry, 2020, 139 : 2553 - 2563
  • [6] Numerical simulation and experimental investigation of air cooling system using thermoelectric cooling system
    Moazzez, A. Fattahpour
    Najafi, G.
    Ghobadian, B.
    Hoseini, S. S.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2020, 139 (04) : 2553 - 2563
  • [7] Investigation to Enhance the Performance of Computer Processor Cooling System
    Prasad, P. Gayathri
    Chilamkurti, L. V. R. S. V. Prasad
    Santarao, K.
    5TH INTERNATIONAL CONFERENCE ON MATERIALS AND MANUFACTURING ENGINEERING-2020 (ICMME-2020), 2020, 954
  • [8] Investigation on forced air-cooling strategy of battery thermal management system considering the inconsistency of battery cells
    Wang, Chun
    Xi, Huan
    Wang, Meiwei
    APPLIED THERMAL ENGINEERING, 2022, 214
  • [9] NUMERICAL ANALYSIS AND OPTIMIZATION OF THERMAL PERFORMANCE OF LITHIUM BATTERY PACK BASED ON AIR-COOLING STRATEGY
    Hu, Yu
    Mao, Bin
    THERMAL SCIENCE, 2022, 26 (05): : 4249 - 4258
  • [10] Investigation of Parameter Effect to Performance of Battery's Cooling System
    Li, Zhen-Zhe
    Pan, Xiao-Ming
    Ren, Ming
    Li, Mei-Qin
    Shen, Gui-Ying
    MATERIALS PROCESSING TECHNOLOGY II, PTS 1-4, 2012, 538-541 : 2015 - 2019