R2*Relaxometry for the Quantification of Hepatic Iron Overload: Biopsy-Based Calibration and Comparison with the Literature

被引:70
作者
Henninger, B. [1 ]
Zoller, H. [2 ]
Rauch, S. [1 ]
Finkenstedt, A. [2 ]
Schocke, M. [1 ]
Jaschke, W. [1 ]
Kremser, C. [1 ]
机构
[1] Med Univ Innsbruck, Radiol, A-6020 Innsbruck, Austria
[2] Med Univ Innsbruck, Internal Med, A-6020 Innsbruck, Austria
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2015年 / 187卷 / 06期
关键词
abdomen; MR imaging; iron; imaging sequences; metabolic disorders; MAGNETIC-RESONANCE; IN-VIVO; LIVER; THALASSEMIA; VARIABILITY; STORES; REGION; R2;
D O I
10.1055/s-0034-1399318
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We compared the calibration of hepatic iron based on R2* relaxometry and liver biopsy with similar studies that have already been published to investigate the transferability of published calibration curves. Materials and Methods: 17 patients with clinically suspected hepatic iron overload (HIO) were enrolled. All patients underwent liver biopsy and MRI of the liver using a multi-echo gradient echo sequence (TR = 200 ms; TE-initial 0.99 ms; Delta-TE 1.41 ms; 12 echos; flip-angle: 20 degrees). R2* parameter maps were analyzed using manually placed regions of interest and R2* values were correlated with liver iron concentration (LIC) obtained from liver biopsy. In addition, the results of our study were compared with 6 similar, already published studies. Results: A linear relationship between R2* and LIC was found. Regression analysis yielded a correlation coefficient of 0.926, a slope of 0.024 (s mg/g) [95 % CI 0.013 - 0.024] and an intercept of 0.277 (mg/g) [95 % CI -0.328 - 2.49]. We found a significant correlation between the calibration curves obtained from our study in comparison to 3/6 similar studies. The other 3 studies used a different reference standard or sequence parameters which lead to a significant difference for slope, intercept or both in comparison to our data. Conclusion: Calibration curves from published studies that are based on a correlation of liver biopsy and R2* can be used for the estimation of liver iron concentration, although different scanning parameters and post-processing protocols were used. Low initial TEs might be a prerequisite for pooling data for liver iron quantification.
引用
收藏
页码:472 / 479
页数:8
相关论文
共 29 条
[1]   How I treat hemochromatosis [J].
Adams, Paul C. ;
Barton, James C. .
BLOOD, 2010, 116 (03) :317-325
[2]   Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload [J].
Anderson, LJ ;
Holden, S ;
Davis, B ;
Prescott, E ;
Charrier, CC ;
Bunce, NH ;
Firmin, DN ;
Wonke, B ;
Porter, J ;
Walker, JM ;
Pennell, DJ .
EUROPEAN HEART JOURNAL, 2001, 22 (23) :2171-2179
[3]   Hepatic iron concentration and total body iron stores in thalassemia major. [J].
Angelucci, E ;
Brittenham, GM ;
McLaren, CE ;
Ripalti, M ;
Baronciani, D ;
Giardini, C ;
Galimberti, M ;
Polchi, P ;
Lucarelli, G .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 343 (05) :327-331
[4]   HEPATIC IRON STORES AND PLASMA FERRITIN CONCENTRATION IN PATIENTS WITH SICKLE-CELL-ANEMIA AND THALASSEMIA MAJOR [J].
BRITTENHAM, GM ;
COHEN, AR ;
MCLAREN, CE ;
MARTIN, MB ;
GRIFFITH, PM ;
NIENHUIS, AW ;
YOUNG, NS ;
ALLEN, CJ ;
FARRELL, DE ;
HARRIS, JW .
AMERICAN JOURNAL OF HEMATOLOGY, 1993, 42 (01) :81-85
[5]  
Butensky E, 2005, AM J CLIN PATHOL, V123, P146, DOI 10.1309/PUUXEGXDLH26NXA2
[6]   Liver iron concentration quantification by MRI: are recommended protocols accurate enough for clinical practice? [J].
Castiella, Agustin ;
Alustiza, Jose M. ;
Emparanza, Jose I. ;
Ma Zapata, Eva ;
Costero, Belen ;
Diez, Maria I. .
EUROPEAN RADIOLOGY, 2011, 21 (01) :137-141
[7]   MRI assessment of liver iron content in thalassamic patients with three different protocols: comparisons and correlations [J].
Christoforidis, Athanasios ;
Perifanis, Vassilios ;
Spanos, George ;
Vlachaki, Efthimia ;
Economou, Marina ;
Tsatra, Ioanna ;
Athanassiou-Metaxa, Miranda .
EUROPEAN JOURNAL OF HAEMATOLOGY, 2009, 82 (05) :388-392
[8]  
Crisponi G, 2000, CLIN CHEM, V46, P1185
[9]  
Emond MJ, 1999, CLIN CHEM, V45, P340
[10]   Non-invasive assessment of hepatic iron stores by MRI [J].
Gandon, Y ;
Olivié, D ;
Guyader, D ;
Aubé, C ;
Oberti, F ;
Sebille, V ;
Deugnier, Y .
LANCET, 2004, 363 (9406) :357-362