Tailoring biomaterial compatibility:: In vivo tissue response versus in vitro cell behavior

被引:105
作者
Mattioli-Belmonte, M
Giavaresi, G
Biagini, G
Virgili, L
Giacomini, M
Fini, M
Giantomassi, F
Natali, D
Torricelli, P
Giardino, R
机构
[1] Univ Politecn Marche, Fac Med & Chirurg, Ist Morfol Umana Normale, I-60020 Ancona, Italy
[2] Rizzoli Orthoped Inst, Res Inst Codivilla Putti, Dept Expt Surg, Bologna, Italy
[3] Univ Genoa, Dept Commun Comp & Syst Sci, I-16145 Genoa, Italy
[4] Univ Bologna, Fac Med, Chair Surg Pathophysiol, Bologna, Italy
关键词
experimental study; cell culture; electroactive polymers; bioresorbable polymers;
D O I
10.1177/039139880302601205
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Biocompatibility relies essentially on surface phenomena, represented by cell-cell, cell-material and material (polymer)-protein interactions. An in vivo and in vitro experimental investigation was carried out on the biomaterials of two different classes with a good potential for in situ utilisation. Non-resorbable (Polypyrrole, Polyaniline, Polyimide) and resorbable (PLLA-PDXO-PLLA) materials for tissue engineering were studied for their overall tissue tolerance and cellular interactions. These non-resorbable polymers conceived for biosensor applications and implantable drug-delivery systems are intrinsically conductive. The PLLA-PDXO-PLLA triblock copolymer showed interesting tensile properties for bone and cartilage tissue engineering due to the presence of 1,5-dioxepan-2-one. In vitro and in vivo parallel studies showed an interesting correspondence: a) the cells in contact with the resorbable material that appeared to be capable of migratory-regenerative aspects in vitro exhibited good compatibility in vivo; whereas b) the non-resorbable materials, which are designed to remain in situ in vivo, were seen to have the potential to represent an adverse factor (inflammation, fibrotic reactions) that correlated with some aspects of cell behaviour in vitro.
引用
收藏
页码:1077 / 1085
页数:9
相关论文
共 36 条
  • [1] Host response to tissue engineered devices
    Babensee, JE
    Anderson, JM
    McIntire, LV
    Mikos, AG
    [J]. ADVANCED DRUG DELIVERY REVIEWS, 1998, 33 (1-2) : 111 - 139
  • [2] THE ACUTE-PHASE RESPONSE
    BAUMANN, H
    GAULDIE, J
    [J]. IMMUNOLOGY TODAY, 1994, 15 (02): : 74 - 80
  • [3] Evaluation of systemic metal diffusion after spinal pedicular fixation with titanium alloy and stainless steel system: a 36-month experimental study in sheep
    Brayda-Bruno, M
    Fini, M
    Pierini, G
    Giavaresi, G
    Rocca, M
    Giardino, R
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2001, 24 (01) : 41 - 49
  • [4] Brunski J B, 1999, Adv Dent Res, V13, P99
  • [5] Biomedical surface science: Foundations to frontiers
    Castner, DG
    Ratner, BD
    [J]. SURFACE SCIENCE, 2002, 500 (1-3) : 28 - 60
  • [6] Collier JH, 2000, J BIOMED MATER RES, V50, P574, DOI 10.1002/(SICI)1097-4636(20000615)50:4<574::AID-JBM13>3.0.CO
  • [7] 2-I
  • [8] In vivo studies of polypyrrole/peptide coated neural probes
    Cui, XY
    Wiler, J
    Dzaman, M
    Altschuler, RA
    Martin, DC
    [J]. BIOMATERIALS, 2003, 24 (05) : 777 - 787
  • [9] Resorbable device for fracture fixation: In vivo degradation and mechanical behaviour
    Fini, M
    Giannini, S
    Giardino, R
    Giavaresi, G
    Grimaldi, M
    Aldini, NN
    Orienti, L
    Rocca, M
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1995, 18 (12) : 772 - 776
  • [10] In vitro behaviour of osteoblasts cultured on orthopaedic biomaterials with different surface roughness, relative to uncoated and fluorohydroxyapatite-coated, the in vivo osteointegration rate
    Fini, M
    Giardino, R
    Borsari, V
    Torricelli, P
    Rimondini, L
    Giavaresi, G
    Aldini, NN
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2003, 26 (06) : 520 - 528